background image

1

Sales 800-633-0405

www.productivity2000.com

Terminal Block sold separately, (see wiring options on page 5).

Warranty: Thirty-day money-back guarantee. Two-year limited 

replacement. (See www.productivity2000.com for details).

1+0.100V

2  4.00

3 13.78

4-4.741V

2000

WARNING:

 

To minimize the risk of potential safety problems, you should 

follow all applicable local and national codes that regulate the installation 

and operation of your equipment. These codes vary from area to area and 

it is your responsibility to determine which codes should be followed, and 

to verify that the equipment, installation, and operation are in compliance 

with the latest revision of these codes.

Equipment damage or serious injury to personnel can result from the 

failure to follow all applicable codes and standards. We do not guar-

antee the products described in this publication are suitable for your 

particular application, nor do we assume any responsibility for your 

product design, installation, or operation.

If you have any questions concerning the installation or operation of this 

equipment, or if you need additional information, please call Technical 

Support at 770-844-4200.

This publication is based on information that was available at the time it 

was printed. At AutomationDirect.com

®

 we constantly strive to improve 

our products and services, so we reserve the right to make changes to 

the products and/or publications at any time without notice and without 

any obligation. This publication may also discuss features that may not be 

available in certain revisions of the product.

Removable Terminal Block Specifications

Part Number

P2-RTB

P2-RTB-1

Number of  

positions

18 Screw Terminals

18 Spring Clamp Terminals

Wire Range

30 - 16 AWG (0.051 - 1.31 mm²)
Solid / Stranded Conductor
3/64 in. (1.2 mm) Insulation Maximum
1/4 in (6 - 7 mm) Strip Length

28-16 AWG (0.081 - 1.31 mm²)
Solid / Stranded Conductor
3/64 in (1.2 mm) Insulation Maximum
19/64 in (7 - 8 mm) Strip Length

Conductors

“USE COPPER CONDUCTORS, 75ºC” or equivalent.

Screw Driver 

Width

1/8 in (3.8 mm) Maximum

Screw Size

M2

N/A

Screw Torque

2.5 lb·in (0.28 N·m)

N/A

P2-04DA Analog Output

The P2-04DA Voltage/Current Analog Output  

Module provides four channels of ±10VDC or 4-20 mA 

sink/source selectable outputs for use with the  

Productivity2000 System

Warning  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Removable Terminal Block Specifications. . . . . . . .  1

General Specifications   . . . . . . . . . . . . . . . . . . . . . . 2

Output Specifications   . . . . . . . . . . . . . . . . . . . . . . . 2

Wiring Diagram and Schematic . . . . . . . . . . . . . . . . 3

Module Installation Procedure . . . . . . . . . . . . . . . . . 4

QR Code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Hot Swap Information  . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Module Configuration   . . . . . . . . . . . . . . . . . . . . . . . 5

Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Non-Linear Scaling  . . . . . . . . . . . . . . . . . . . . . . . . . 6

OLED Panel Display Menus  . . . . . . . . . . . . . . . . . . 7

Содержание Productivity 2000 P2-04DA

Страница 1: ... information that was available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block...

Страница 2: ... Mode Voltage outputs 0V or 0mA current outputs Load Impedance Minimum External Power Supply 1000Ω voltage outputs 19 2 30 VDC 0 755Ω Sinking 0 600Ω Sourcing 19 2 VDC 0 875Ω Sinking 0 700Ω Sourcing 21 6 VDC 0 1000Ω Sinking 0 855Ω Sourcing 24VDC 0 1110Ω Sinking 0 970Ω Sourcing 26 4 VDC 0 1350Ω Sinking 0 1150Ω Sourcing 30VDC Maximum Capacitive Load 0 01μF maximum voltage outputs Maximum Inductive Lo...

Страница 3: ...DC User Supplied Power Transmitter Power Supply AC or DC 4 wire 4 20mA Load Transmitter Power Supply I I V1 I1 I1 COM V2 I2 24VDC I2 24VDC 24VDC 24VDC 24 VDC User Supplied Power CH1 DAC CH2 DAC ANALOG CIRCUIT POWER ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY voltage sink source 4 20 mA current sinking 4 20 mA current sourcing voltage sink source 4 20 mA current sinking 4 20 mA current sourcing...

Страница 4: ...n your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mod...

Страница 5: ... Bit Item Range with sink source option and Stop Mode Value may also be assigned Wiring Options 1 ZIPLink Connection System Cable ZIPLink Module Complete System ZIPLink pre wired terminal block cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZIPLink Modules Feed through ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 ZL RTB20 2Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ...

Страница 6: ...0 0 0 0 0 1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 The Scale Linear function can be used to Convert an application specific range to a range which is native to the analog output module Make other linear con...

Страница 7: ...nto the cycling Status Info screen This screen will auto cycle with status information PASSED SELF TEST P2 04DA Fw Rev 1 00 1 10V 2 mA SRC 3 mA SNK 4 10V DISPLAY SETUP INFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY STATUS INFO DISPLAY UNITS VOLT OR MILLIAMP 1 00000 2 00000 3 00000 4 00000 1 0000H 2 0000H 3 0000H 4 0000H 1 0 000V 2 4 00 3 13 90 4 4 741V End of Status Menu List M...

Страница 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 04DA DS 1st Ed 3 9 2015 Copyright 2015 AutomationDirect com Incorporated All Rights Reserved Worldwide ...

Отзывы: