background image

6

Tech Support 770-844-4200

www.productivity2000.com

65535

220

12500

Tank Level

0

Control Valve 

Select the Input and Output tags appropriate 

for the application. Convert raw input signals 

to engineering units for use in the program, or 

convert engineering units to output signals for 

control purposes 

max 

 

 

 

 

 

 

 

min 

min 

 

max 

0

.5

1

1.55

2.25

3

4.55

6.75

7

0

0

0

0

0

0

0

0

1

2

3

4

5

6

6.5

7

0

0

0

0

0

0

0

Level Transmitter

Tank Level

7

0

0

0

0

0

0

0

Select the minimum and maximum 

values of the raw input signal. These 

values will relate to the minimum 

and maximum scaled values.

7
6
5
4
3
2
1
0

1   2   3   4   5   6   7  

The Scale (Linear) function can be used to:
• Convert an application specific range to a range which is native to the 

analog output module.

• Make other linear conversions in ranges appropriate to the application.

The Scale (Non-Linear) function can be used for Non-Linear applications.

Linear Scaling

Non-Linear Scaling

Содержание Productivity 2000 P2-04DA

Страница 1: ... information that was available at the time it was printed At AutomationDirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without any obligation This publication may also discuss features that may not be available in certain revisions of the product Removable Terminal Block...

Страница 2: ... Mode Voltage outputs 0V or 0mA current outputs Load Impedance Minimum External Power Supply 1000Ω voltage outputs 19 2 30 VDC 0 755Ω Sinking 0 600Ω Sourcing 19 2 VDC 0 875Ω Sinking 0 700Ω Sourcing 21 6 VDC 0 1000Ω Sinking 0 855Ω Sourcing 24VDC 0 1110Ω Sinking 0 970Ω Sourcing 26 4 VDC 0 1350Ω Sinking 0 1150Ω Sourcing 30VDC Maximum Capacitive Load 0 01μF maximum voltage outputs Maximum Inductive Lo...

Страница 3: ...DC User Supplied Power Transmitter Power Supply AC or DC 4 wire 4 20mA Load Transmitter Power Supply I I V1 I1 I1 COM V2 I2 24VDC I2 24VDC 24VDC 24VDC 24 VDC User Supplied Power CH1 DAC CH2 DAC ANALOG CIRCUIT POWER ANALOG CIRCUIT COMMON INTERNAL MODULE CIRCUITRY voltage sink source 4 20 mA current sinking 4 20 mA current sourcing voltage sink source 4 20 mA current sinking 4 20 mA current sourcing...

Страница 4: ...n your installation for use of this powerful feature 1 Align with slot 2 rotate to seated position Module Installation WARNING Do not apply field power until the following steps are completed See hot swapping procedure for exceptions WIRESTRIP LENGTH WIRESTRIP LENGTH Step One Align module catch with base slot and rotate module into connector Locked Unlocked Step Two Pull top locking tab toward mod...

Страница 5: ... Bit Item Range with sink source option and Stop Mode Value may also be assigned Wiring Options 1 ZIPLink Connection System Cable ZIPLink Module Complete System ZIPLink pre wired terminal block cables 0 5 m 1 6 ft cable 1 0 m 3 3 ft cable 2 0 m 6 6 ft cable ZIPLink Modules Feed through ZL P2 CBL18 ZL P2 CBL18 1 ZL P2 CBL18 2 ZL RTB20 2Terminal Block with pigtail cable 1 0 m 3 3 ft cable 2 0 m 6 6 ...

Страница 6: ...0 0 0 0 0 1 2 3 4 5 6 6 5 7 0 0 0 0 0 0 0 Level Transmitter Tank Level 7 0 0 0 0 0 0 0 Select the minimum and maximum values of the raw input signal These values will relate to the minimum and maximum scaled values 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 The Scale Linear function can be used to Convert an application specific range to a range which is native to the analog output module Make other linear con...

Страница 7: ...nto the cycling Status Info screen This screen will auto cycle with status information PASSED SELF TEST P2 04DA Fw Rev 1 00 1 10V 2 mA SRC 3 mA SNK 4 10V DISPLAY SETUP INFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY STATUS INFO DISPLAY UNITS VOLT OR MILLIAMP 1 00000 2 00000 3 00000 4 00000 1 0000H 2 0000H 3 0000H 4 0000H 1 0 000V 2 4 00 3 13 90 4 4 741V End of Status Menu List M...

Страница 8: ...8 Tech Support 770 844 4200 www productivity2000 com Document Name Edition Revision Date P2 04DA DS 1st Ed 3 9 2015 Copyright 2015 AutomationDirect com Incorporated All Rights Reserved Worldwide ...

Отзывы: