background image

5

www.automationdirect.com/click-plc

3505 HUTCHINSON ROAD 

CUMMING, GA 30040-5860 

1-800-633-0405

C2-02CPU Quick Start Guide 

Copyright© 2020, 

Automationdirect.com

 Incorporated/All Rights Reserved Worldwide

Setup & Provisioning via Bluetooth

The C2-02CPU can be configured over a Bluetooth, Ethernet 
or micro USB connection. You will need a Windows

®

 PC or 

a mobile device (iOS or Android) and a appropriate antenna 
or cable for the method you choose. This guide covers the 
simplest cases—setting up a new CLICK PLUS device using 
a mobile device over a Bluetooth connection or setup over 
USB connection to a PC. For other setup and provisioning 
methods, including the use of preconfigured provisioning files, 
please see the CLICK PLUS User Manual or Software help file.

Connection Requirements

Method

Requirements

Bluetooth

2.4 GHz antenna* (SE-ANT210 or SE-ANT250)

* A remote-mounted antenna is recommended to connect with the enclosure closed.

PREPARE A MOBILE DEVICE FOR CONNECTION

Install the CLICK PLUS Provisioning App using one of 
the QR codes below, or search for the app in the appropri-
ate app store (CLICK PLUS Provisioning, published by 
Automationdirect.com).

FIND THE NEW CPU

Connect to the CPU as follows:

1. 

Open the 

CLICK PLUS Provisioning App

.

2. 

Tap 

Start

 in the App.

3. 

Cycle power on the CLICK PLUS CPU or press the Pairing 
button on the CLICK PLUS CPU for 1 second. (A factory-
default CPU will be in pairing mode for 30 seconds after power 
is applied.) The blue BT LED will start flashing.

4. 

The App will find the CLICK PLUS PLC that’s in Provisioning 
mode. The blue BT LED will be ON solid when the App is 
connected to the PLC. Tap 

Next

 in the App to continue. 

5. 

If the App detects that the PLC is factory new and the network 
settings have not been configured, it will prompt you to Tap 

Next

 to begin the provisioning process.

Apple Store

Google Play Store

Pairing

Button

BT LED

Flashing

Содержание CLICK PLUS C2-02CPU

Страница 1: ...ICK PLUS CPU PC or Android or iOS mobile device for setup provisioning Click Software ver 3 00 or later PC or Click App mobile device 24VDC power supply SELV and Limited Energy CLICK power supply C0 00AC or C0 01AC is recommended Appropriate enclosure with vertical surface for DIN rail or surface mount M4 screws spring washers and flat washers if surface mounting Ferrules and crimping tool for wir...

Страница 2: ...ent may be invalidated CAUTION For use in Pollution Degree 2 Environment Use and store the equipment in an environment described in the specifications regarding temperature humidity vibrations shock etc in order to avoid equipment damage or fire Ensure all wiring has strain reliefs in order to avoid damage to insulation that might result in electric shock or fire Ensure secondary external power ci...

Страница 3: ...the 4 pin connector located on the bottom of the CPU unit 16 28 AWG wiring is supported We recommend using crimping ferrules on all wire terminations for a more secure connection The following crimping ferrules are recommend ed for the 24VDC power terminals Company Type Model No Compliant Wire AutomationDirect Ferrule V30AE000009 V30AE000041 0 2 0 5 mm2 22 26AWG Maximum tightening torque is 0 22 t...

Страница 4: ...e module into its slot Press the module into place until it is fully seated 3 Push the top and bottom locking clips backward until they click into place Lift slightly on the locking clips until they release then slide each clip forward Reverse the procedure To install an Option Slot Module To install an Option Slot Module To remove an Option Slot Module To remove an Option Slot Module 3 Push the t...

Страница 5: ...r SE ANT250 A remote mounted antenna is recommended to connect with the enclosure closed PREPARE A MOBILE DEVICE FOR CONNECTION Install the CLICK PLUS Provisioning App using one of the QR codes below or search for the app in the appropri ate app store CLICK PLUS Provisioning published by Automationdirect com FIND THE NEW CPU Connect to the CPU as follows 1 Open the CLICK PLUS Provisioning App 2 Ta...

Страница 6: ... need to connect SET UP NETWORK PARAMETERS 9 Once the PLC is connected to the wireless access point or wired network choose which IP address configuration to use then tap Next to continue 9a Use DHCP Automatically assign a network IP address to the CLICK PLUS PLC This is often the simplest way to connect 9b Use Default Fixed Address Wireless 192 168 0 11 Wired 192 168 0 10 9c Use the following IP ...

Страница 7: ...g No Error Off Blink WLAN LED Green On Link Activity No Link Off Blink POWER LED Green On Power Good USB Low Power Mode Power Failure Off Blink RUN LED Green On CPU Run Mode Initializing Analog Module CPU Program Mode Off Blink LED Status Indicators Connecting via USB To connect the CLICK PLUS CPU to a PC use a USB A to USB micro B cable such as the AutomationDirect USB CBL AMICB6 cable 1 Connect ...

Страница 8: ...0 MC BAT recommended Technical Specifications Power Specifications Power Input Voltage Range 20 28 VDC Class 2 or SELV Safety Extra Low Voltage or Limited Energy Circuit power supply Maximum Power Consumption 20W Maximum Inrush Current 30A 1ms Acceptable External Power Drop Max 10ms AC Power Failure with C0 00AC or C0 01AC Wire Range 16 28 AWG Wire Strip Length 7 0 mm Wire Specification Lead free ...

Страница 9: ...0 Automationdirect com Incorporated All Rights Reserved Worldwide Mechanical Drawings Unit Dimensions mm in BLUETOOTH PAIRING MODE SWITCH MICRO USB POWER TERMINAL BLOCK OPTIONAL MODULE SLOT ANTENNA STATUS LED s 101 8 4 01 85 0 3 35 46 6 1 83 46 4 1 83 FULLY EXTENDED OVERALL 53 5 2 11 60 8 2 39 32 3 1 27 126 8 4 99 PART NO SE ANT210 ...

Страница 10: ...mmunications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The C2 02CPU complies with Part 15 247 modular Inten tional Radiator FCC rules and regulations Changes or mod ifications not expressly approved by AutomationDirect could void the user s authority to operate the...

Отзывы: