16
•
C4-2350-GigE Camera Hardware Reference Manual Rev. 2.1
The GenICam Features Configuration of C4-2350-GigE
Due to dependencies of the XML nodes of C4-2350-GigE registers, it is recommended to follow a
specific order, when configuring the GenICam features of the camera. The list shown below,
generated as a CXC file by the CX-Explorer, demonstrates an example of the correct write order:
CameraMode CenterOfGravity
ProfileTriggerMode FreeRun
EnableDC2 1
EnableDC1 0
TestImageSelector Off
PixelFormat Mono8
Width 2352
ReverseY 0
ExposureTimeAbs 100
FramePeriode 5218
ShortIntegrationMode 1
DarkOffsetEnable 1
UsePersistentFPNdata 1
NumAois 1
AoiSelector 1
AoiHeight 1728
AoiOffsetY 0
AoiThreshold 128
AbsOffsetPos 0
TrshFirstFalling 0
NumCOGSP 6
ValidationWidthMin 0
ValidationWidthMax 1727
ValidationSumMin 0
ValidationSumMax 65535
CameraMode CenterOfGravity
ProfilesPerFrame 100
ClearInvalidPos 0
PosValidationEn 0
EnableDC0 0
EnableDC1 0
EnableDC1TrshWidth 0
EnableDC1Width 0
EnableDC1Flags 0
EnableDC2 1
EnableDC2TrshSP 0
EnableDC0Shift 1
AcquisitionFrameCount 1
AcquisitionMode Continuous
Output1 Out1_SequencerActive
Output2 Out2_IntegrationActive
LaserPower 0
TurnLaserOn 0
TurnLaserOnAuto 0
Output1MinPulseWidth 0
Output2MinPulseWidth 0
Output1Delay 0
Output2Delay 0
Output1Invert 0
Содержание C4-2350-GigE