62
•
C2-2040(HS)-GigE Camera Hardware Reference Manual Rev. 1.8
-
the isolated inputs of the C2-I/O panel Rev. 2.0 can be operated both with 5V and 24V
DC signals. The voltage level can be set over the DIP switch S400:
-
the panel features a 1A fuse for camera protection
-
the type of encoder signal (differential or single-ended) can be set over the DIP switch
S300:
S400 IN1 IN2
ON
5V 5V
OFF
24V 24V
Track A
Track B
Track Z
n.c.
IN1
IN2
ON
Differential
Single-Ended
OFF