![Automation Dr. Nix QNix 1500 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/automation-dr-nix/qnix-1500/qnix-1500_instruction-manual_3021815009.webp)
statistical evaluation on your PC is optionally available.
For further information concerning ”Data Processing“ please
refer to the software.
Possible Display Information
1. Fe = Measurement on steel or iron substrates
2. NFe = Measurement on non-ferrous metallic substrates
3. ERR = Incorrect handling
4. INFI = Incorrect substrate, e.g. measuring beyond the
measuring range or measuring on wood
5. BAT
=
Battery is getting weak, please exchange.
Information: the measured values will remain
stored.
6. bloc = Displayed alternating with the block number
7. End = Memory or block capacity out of space
8. N
= a) alternating with Fe or NFe
= number of measurements
b) alternating with Ae
= number of measurements of the active block
9. Ae = Average value measured in the active block
10.
= Maximum value measured in the active block
11.
= Minimum value measured in the active block
Accessories
The electronic coating thickness gauge
QNix® 1500
is
delivered with a carrying case containing Fe and NFe zero
plates, a 9 V alkaline battery, two probe protection rings and
Instruction Manual.