STRATUS TA20 Series Industrial Air Conditioners User Manual
1st Edition RevA. 

Unpacking STRATUS  

Air Conditioning Equipment 

Always keep air conditioner unit top up as shown by the 
packaging label and arrows. If the unit is to be transported after 
initial unpacking and inspection, place air conditioner back in 
original packing to prevent damage.
For shipment, repack as received and re-band to the pallet. 
Shipping without being strapped to the pallet may result in 
tipping and damage and voids the warranty.

Air conditioners are not designed to be shipped attached to an 
equipment enclosure. If this is required, the air conditioner must 
have sufficient support to prevent damage due to vibration and 
shock. Air conditioners damaged internally, due to being shipped 
attached to enclosures, are warranty voided.

Inspecting the Equipment

STRATUS air conditioning equipment is designed, 
manufactured and packed to prevent damage from normal 
handling,  shock and vibration during shipment. Please be sure 
to inspect your equipment upon receipt to ensure that there is 
no visual or hidden damage.
Upon receipt of the equipment, ensure that it is always top side 
up as indicated by “THIS SIDE UP” labels; this ensures that the 
compressor oil is not displaced. 

If the equipment has been on its side, it must be put upright for at 
least 24 hours before running to be certain the compressor oil has 
returned to the compressor.

All physical damage to packing or signs of damage to the 
equipment must be noted on the freight bill of lading. 
Packages must be opened after receipt to inspect for any 
internal /concealed damage to the equipment and to 

 

verify proper count and order fulfillment. Shipments delivered 
without the pallet, not top-side up, other freight on top, 
damaged or wet should be refused delivery. Contact the 
shipper immediately upon discovery of shipping damage to 
schedule inspection by the freight company. Keep all packing. 
AutomationDirect cannot take responsibility for customer’s  
failure to file freight damage claims on a timely basis.

1000 and 2000 BTU/Hour Models

• 1 Pre-bagged Hanger Bolt Kit includes  
  (10)  - 1/4 - 20 x 3/4  Machine Screws/ Unslotted/ Indented Hex Washer Head, Steel/Zinc
  (10)  - 1/4  Medium Split Lock Washers, Steel/Zinc
  (10)  - 1/4 Flat Washer/Machine Screw, Steel/Zinc
• Rubber Seal Gasket X-114HT Pre-Cut, QTY 8.5 feet.  NEMA/UL Type 4 and 4X units have gasket installed
• Instruction / Operation Manual 
• Actual Size Mounting Template

What’s in the Box

Upon receipt of the STRATUS Air 
Conditioner, please check for the following:

•  Make sure that the box contains all items 

required for installation of your series.

•  Inspect the unit to ensure it was not 

damaged during shipment.

•  Make sure that the part number 

indicated on the serial number label 

corresponds with the part number of 

your order.

Volts                      Amps 

     Phase 

     Hz 60

Refrigerant                                           Ounces

Design Pressure:

Low Side 

  psi  High Side 

  psi

Motor-Compressor Thermally Protected

UL Type 12, 04, 4X Interface to Electronic Enclosure per UL 50 & 508a

Special Purpose

Air Conditioner

S/N

MODEL No.

BTU

/H

NEMA Type

Automation Direct 

• 

800.633.0405

www.automationdirect.com

UL File # SA33404

Input Specification

Refrigerant Type/Weight

Refrigerant Pressure

Enclosure Rating

A/C Unit Serial Number

A/C Unit Model Number

Nameplate Information

Be sure to record the data from the label onto the back 
of the manual and keep in a safe place for warranty.

WARNING: Before operating the air conditioner, 
inspect all electrical wiring to ensure proper  
installation and wiring to the proper power source.  
The minimum circuit amperage must be 125% of the 
air conditioner label amperage listed for the voltage 
selected. 

Содержание Stratus TA20 Series

Страница 1: ...1 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA20 Series Industrial Air Conditioners User Manual 1st edition RevA TA20 Series User Manual...

Страница 2: ...clude the Manual Number and the Manual Issue both shown below when communicating with Technical Support regarding this publication Manual Number Stratus_TA20_UM_WMO_1ed Issue 1st Edition Issue Date 12...

Страница 3: ...ox 6 Nameplate Information 6 Inspecting the Equipment 6 Basic Operation 7 Features 8 Unit Specifications 8 Preliminary Testing 10 Mounting the Air Conditioner 10 System Operation 11 System Faults 11 A...

Страница 4: ...en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publica tion et toutes les autres publications pertinentes avant de l installer ou de l utiliser Afin de r...

Страница 5: ...vailable weekdays from 9 00 a m to 6 00 p m Eastern Time We also encourage you to visit our web site where you can find technical and non technical information about our products and our company Visit...

Страница 6: ...he pallet not top side up other freight on top damaged or wet should be refused delivery Contact the shipper immediately upon discovery of shipping damage to schedule inspection by the freight company...

Страница 7: ...of 95 F plus the temperature differential of 5 F As the refrigerant pressure builds to a factory setpoint the condenser fan turns on to force air flow across the coils Refrigerant low pressure and hig...

Страница 8: ...ser inlet air filter Thermal expansion valve provides high performance over wide temperature range Internally insulated to minimize case heat loss Schrader valves on low AND high pressure service port...

Страница 9: ...26 4X 230 60 2 00 45 12 00 NEMA Type 4 Unit Specifications Model BTU H Max Ambient Temperature Standard Max Ambient Temperature Volts Hertz Running Amps Unit Weight lb Refrigerant Type Refrigerant Amt...

Страница 10: ...with the unit Using the template supplied determine where the air conditioner is to be mounted and make sure that all required cuts and holes will not interfere with or damage the enclosure There mus...

Страница 11: ...condition is indicated on the front panel and an alarm contact operates for remote alarming Three main conditions can shut down the AC compressor The condenser high temperature alarm The evaporator co...

Страница 12: ...t unit F Flashing Programming phase Digital Temperature Controller Overview The microprocessor based digital temperature controller performs the functions of controlling the enclosure temperature whil...

Страница 13: ...ey to display its value 3 Press the UP or DOWN arrow key to change its value 4 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow keys or wait 15 seconds w...

Страница 14: ...fter initial 30 min delay Alarm relay operates HA2 Condenser high temperature P2 L 145 F for 3 minutes Alarm relay operates compressor off LA2 Condenser low temperature P2 l 50 F for 3 minutes Alarm r...

Страница 15: ...oil cleaning compounds and thorough back flush rinsing Refer to directions on the cleaning compounds selected Acid wash is not recommended as it reduces the life of the coil Note Do not use solvents t...

Страница 16: ...locked Installation must meet minimum clearance for condenser air flow Adjacent unit heating air Install baffle deflector or move unit s Perform touch test Compressor hot 190 F Suction accumulator col...

Страница 17: ...a u t o m a t i o n d i r e c t c o m STRATUS TA20 Series Industrial Air Conditioners User Manual 1st edition RevA Typical Frame Size TA20 0 1000 BTU H Units Dimensions All dimensions inches millimete...

Страница 18: ...5 18 STRATUS TA20 Series Industrial Air Conditioners User Manual 1st Edition RevA w w w a u t o m a t i o n d i r e c t c o m Typical Frame Size TA20 1 2000 BTU H Units Dimensions All dimensions inche...

Страница 19: ...RATUS TA20 Series Industrial Air Conditioners User Manual 1st edition RevA 1 8 0 0 6 3 3 0 4 0 5 Cutout for Typical Frame Size TA20 0 1000 BTU H Units Dimensions All dimensions inches millimeters Cuto...

Страница 20: ...1 8 0 0 6 3 3 0 4 0 5 20 STRATUS TA20 Series Industrial Air Conditioners User Manual 1st Edition RevA Schematic 1000 BTU 48VDC...

Страница 21: ...21 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA20 Series Industrial Air Conditioners User Manual 1st edition RevA Schematic 1000 BTU 120V...

Страница 22: ...1 8 0 0 6 3 3 0 4 0 5 22 STRATUS TA20 Series Industrial Air Conditioners User Manual 1st Edition RevA Schematic 2000 BTU 120 240VAC...

Страница 23: ...cement Parts Wiring Terminal Blocks for Stratus Air Conditioners Manufacturer Manufacturer Part Description 2000 BTU Models Phoenix Contact 1718504 Plug Component Phoenix Contact 1716522 Feedthrough H...

Страница 24: ...1 8 0 0 6 3 3 0 4 0 5 24 STRATUS TA20 Series Industrial Air Conditioners User Manual 1st Edition RevA...

Отзывы: