background image

34

Axess® Pro Series 3000 

Owner Installation Instructions

Service Counter
(Cycles)  60000

1: Open Cycles
(Cycles)   500

56

fi g

55

fi g

Menu 8.5 Service Counter 

The opener provides a periodic service counter which 
can be set to expire after a number of drive cycles. 
When expired, the opener will beep three times at 
the beginning of each drive cycle and a message will 
be displayed on the MAIN SCREEN 

(Fig. 55)

This 

tool displays the current value of the service counter 
and allows the user to set its value using the normal 
parameter editing techniques (See PARAMETER 
VIEWING AND EDITING). If the service counter is not 
to be used, it can be set to the maximum number 
(60,000). 

Menu 8.6 Event Counters 

The opener keeps a count of number of times a 
particular event occurs. The list of event counters 
kept is shown below. When this tool is selected, the 
fi rst event counter is shown

 

(Fig. 56)

.

 Press NEXT or 

PREV to step through the list. The example shows the 
OPEN CYCLE event counter with a value of 500. When 
fi nished viewing press STOP. 

1: Open Cycles                    2: Close Cycles
3: PED Cycles                      4: Setup Limits 
5: Warranty Cycles               6: Open O/LS
7: Close O/LS 

              8: Open Stalls 

9: Close Stalls                    10: Direction Faults
11: Position Sensor faults  12: Drive Memory Faults
13: Position Wrap Faults   14: Console Volt Faults
15: PCB Temp Fault           16: Comms Compat Faults 
17: INV logic faults             18: Low DC Bus Volt Faults

Menu 8.7 Install Data

Open Position

 

Shows the fully open position door counter.

PED Position

 

Shows the pedestrian position counter.

Open Time

Time taken for the opener to drive the door to open 

position.

Close Time

Time taken for the opener to drive the door to the 
close position.

Diagnostic Tools

Menu 8.8 Parameters

Position of the limit counter, Frequency, 

current 

used by the motor, 

Overload graph, PCB 

temperature and DC bus voltage are displayed 
under this menu.

All the parameters mentioned above can also be 
viewed while the opener is running. By default,

 

the current used by the motor will be displayed 
on the LCD screen. This can be useful to check 
the condition of the door. Scroll through other 
parameters by pressing NEXT or PREV buttons 
while the door is running

Menu 8.9 Version Info

Firmware information for the Axess® Pro Series 
3000 shutter opener’s drive and console are 
shown here.

Содержание Axess Pro Series 3000

Страница 1: ...Axess Pro Series 3000 Commercial Shutter Opener Featuring TrioCode Technology INSTALLATION INSTRUCTIONS OWNERS COPY Part 92647 Manual V1 00 ...

Страница 2: ...s statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd commercial shutter opener Automatic Technology Australia Pty Ltd hereby further expressly excludes all or any liability for any injury damage cost expense or claim whatsoever suffered by any person as a result whether directly or indirectly from failure to inst...

Страница 3: ...Editing Parameters 15 Setting Limits 16 Setting Limits Via Transmitter 17 Coding Transmitters 18 Transmitter Editing 19 Transmitter Management 21 Remotely Coding Transmitters 23 Setting Pedestrian Position 24 Reprofiling The Door Travel 24 Control Board Adjustments 25 Current Trips 25 Auto Close Times 25 Light Times 26 Motor Settings 27 Time Clock 31 Diagnostic Tools 33 Memory Tools 35 Specification...

Страница 4: ...Any device that can operate the opener make sure it is out of reach of children and that the doorway is in full view at all times Serious personal injury and or property damage can result from failure to follow this warning DO NOT wear rings watches or loose clothing while installing or servicing Axess pro series 3000 shutter opener The opener is not intended for use by young children or infirm per...

Страница 5: ... beam must be fitted correctly and tested for operation at regular intervals Extreme caution is recommended when using Auto Close mode All Safety Instructions above must be followed Make sure that the door is fully open before driving into or out of the driveway And make sure the door is fully closed before leaving the driveway Frequently examine the installation in particular guides and mountings ...

Страница 6: ...ystem that greatly simplifies installation adjustment and status indication Features include editing transmitter storage and names setting various parameters selecting specialised operating modes and performing system diagnostics Status Indication The status of the door opener can be determined at anytime by observing the console s screen When the MAIN SCREEN is displayed the current position of th...

Страница 7: ...of these outputs can be adjusted to suit your needs Extensive Operating Modes Via Control Inputs And Remote Control The integrated controller can be configured to operate in many different ways via its 7 control and safety inputs These include P E FIRE GPI OPEN STOP CLOSE and SWIPE Remote control operation is provided with each transmitter s button being able to be configured to operate one of OSC P...

Страница 8: ...ork Cable 1 Output Drive Shaft Assembly 1 Chain 10B 0 625 1 Sprocket 14x0 625 assembly 1 Mounting Flange 1 Ax30 Fasterner Pack 1 TrioCode Keyring Transmitters 2 Installation Manual 1 EasyBeam with wires and brackets 1 Wall Control Unit Transmitters EasyBeam Network Cable Timing assembly Chain 10B M ounting Flange Output Drive Shaft Sprocket Fastner Pack ...

Страница 9: ...eries 3000 9 Controller Input And Outputs Motor identification harness connector cluch interlock microswitch connector Serial Interface Connector Position Sensor Connector 10 Amps Slow Blow FuseStandby Battery 03 04 02 01 05 01 02 03 04 05 02 fig ...

Страница 10: ...ire EasyBeam Input AUX OUT Receiver s Auxiliary Output FIRE N O N C Input Terminal GPI N O Input Terminal OPN N O N C Input Terminal STP N O N C Input Terminal CLS N O Input Terminal SWP N O Input Terminal COM Terminal For Inputs Programmer PG 3 Input Console Previous Button Liquid Crystal Display Console Next Button Console Open Button Console Stop Button Console Set Button Console Close Button 0...

Страница 11: ... distance between the drive unit and the imposing structure 10mm The overhead clearance needs to be at least 150mm Step 2 Drive Unit Pre assembly The opener can be installed on either the right or left hand side of the door when viewed from inside the building The timing assembly mounting flange and drive shaft needs to be assembled according to the installation side Assembling the opener for RIGHT...

Страница 12: ...ual chain through guide and over the clutch pulley Shorten chain as required and fix ends to make a loop NOTE ensure that hand chain is not twisted when making a loop Step 4 Installing The Wall Control Unit Remove the main cover Affix the wall control unit at a height of 1 5 metres within sight of the door Make sure that the position of the wall control unit is out of reach of children and convenien...

Страница 13: ...e doorway Automatic Technology recommend that the sensor is placed 100mm above the floor level and as close as possible to the door opening Connect as per the wiring diagram Fig 11 Step 5 2 Alignment Power up the Axess Pro 3000 series shutter opener with the EasyBeam connected The green LED on the transmitter should turn ON to indicate power is present If the receiver is connected to power and the ...

Страница 14: ...nt history display See page 33 Periodic service cycle counter See page 34 View Parameters See page 34 Memory usage See page 33 Parameter list 1 Open speed frequency 2 Close speed frequency See page 27 See page 27 NOTES 1 Press PREV NEXT buttons move to Left Right 2 Press OPEN CLOSE buttons to change setting 3 Press SET button to save changes 4 Press STOP to return to MENU without saving changes Me...

Страница 15: ...n causes the parameter s value to change rapidly The longer the button is held the faster the value changes 5 Press SET to SAVE setting Reload Default Setting 1 Press NEXT PREV buttons to display LOAD DEFAULT screen 2 Press SET to load the default value Return To Menu If the parameter s value is not to be changed press STOP to return to the sub menu Press STOP again to return to the MAIN SCREEN 12...

Страница 16: ... to change the motor s direction Press and hold the CLOSE button until close position of the door is reached If the door overshoots press the OPEN button to move the door in the open direction When the door is at the desired close position press the SET button to record the close limit position The display will change and green open LED will start to flash Fig 15 Press and hold the OPEN button to o...

Страница 17: ...0 1 3 Press SET two times to enter the limit setting procedure The close blue LED will start to flash Setting Limits Via Transmitter Press and hold Button 4 on the transmitter to close the door If the door opens release button 4 and press the stop button once on the wall control unit to change the direction of the motor Then press and hold Button 4 on the transmitter to close the door If the door i...

Страница 18: ...se to operate the Door Opener e g button 1 Fig 20 3 Press the same transmitter button again as prompted by the display Fig 21 Selecting Function Of The Button The controller will now show the transmitter s record with a cursor on the field for the button being coded Fig 22 Use OPEN CLOSE to select the function for the button Available functions OSC Open Stop Close PED Pedestrian access SWP Swipe CL...

Страница 19: ...l prevent the opener responding to that button Available functions OSC Open Stop Close PED Pedestrian access SWP Swipe CLS Close OPN Open STP Stop LGT Courtesy Light VAC Vacation Mode AUX Auxiliary OFF No action NOTE OSC will change to OS in the case where PE Beams are not installed 3 Press SET to save changes or press NEXT or PREV to move to the next field The example in Fig 26 shows that PED is a...

Страница 20: ...4 Press NEXT PREV to move the cursor over the ID field 5 Press NEXT to reveal the Serial Number Fig 29 The serial number display is provided for additional means of identification The transmitter in this example has serial number 12345 Editing A Character Field 1 Press NEXT or PREV to move select character Fig 30 2 Press UP or DOWN to scroll through and select a new character 3 Press NEXT or PREV to...

Страница 21: ...ce Fig 33 4 Press NEXT to view the transmitter parameters Fig 34 This method is used for quick navigation if the transmitter is available NOTE VIEW will not be shown if the transmitter is not stored Once the list is displayed it can be sorted by stored number ID Label or Serial Number Use the NEXT or PREV buttons to select the sorting method NOTE When sorting by ID label or S N only stored transmi...

Страница 22: ...mitter from memory along with the name and button function settings Edit Operation The edit operation displays the transmitter record for editing purposes See TRANSMITTER EDIT PROCEDURE for details Copy Operation The copy operation is used to code multiple transmitters with the same button function as that of the selected transmitter Once selected an abbreviated code set routine is initiated which...

Страница 23: ... wait for the door to complete its cycle Step 9 3 Activate Remote Code Set Mode Use a small pin to press and hold through the Coding Hole of the existing transmitter for 2 seconds Fig 41 Step 9 4 Code New Transmitter Button Within 10 seconds press the button on the new transmitter you wish to code for 2 seconds Fig 42 Step 9 5 Confirm The Transmitter Button To Be Coded Press the same button again w...

Страница 24: ...he display Fig 44 If a Ped Mode button is pressed while the door is moving the door will stop If a Ped Mode button is pressed when the door is in the Ped position then the door will close Errors During Setting Of Travel Limits And Pedestrian Position During the above procedure many error checks are preformed If an error is detected a message will be displayed indicating the error 1 2 3 4 5 6 Setti...

Страница 25: ...WP input being active The countdown is aborted if the STP input is activated If the door is already open and the OPN or the SWP input is activated then the countdown will start P E triggered Auto Close This mode is selected by entering a non zero time for the P E Auto Close parameter This mode is used to Auto Close the door but only after a vehicle has passed through the doorway and triggered the ...

Страница 26: ... menu 7 Operating modes must be selected ON and also sub menu 4 OPN I P N C operation in menu 7 Operating modes must be selected ON This mode is used to Auto Close the door only after a vehicle has passed through the doorway to exit the premises The 2nd PE OPN input must be active when the PE input is activated in order for a P E triggered Auto Close to be activated This mode is useful for fire bri...

Страница 27: ...beam has been installed This means that the door can only be closed by HOLDING the CLS input or CLOSE button All other means of closing the door are disabled Press SET to continue Menu 6 2 PE Beams Input Response Mode The PE Beams input can be configured to respond in one of three modes Reverses Close Cycles In this mode the PE Beams input has no effect when opening but will cause the door to rever...

Страница 28: ... a second PE Beams input When the OPN input is active the door is prevented from being closed If the OPN input is triggered while the door is closing the controller will stop the motor and then open the door The OPN input has no effect while the door is opening The second PE Beams OPN input must be active when the PE Beams input is activated in order for PE Beams Triggered Auto Close to be activat...

Страница 29: ...ord to be used The password protection feature has a time out that expires after 60 seconds of inactivity Alternatively the user may log out manually by pressing exit when the main screen is displayed 6 17 Transmitter Grouping The transmitter store number display format can be changed to show a grouped format When grouping is selected instead of displaying the store location as a number between 1 ...

Страница 30: ...STP INPUT N C OPERATION Selects operating polarity of STP input Off On Off 6 9 FIRE INPUT N C OPERATION Selects operating polarity of FIRE input Off On Off 6 10 FIRE INPUT MODE configure the fire input Options are OPN CLS and PED OPN CLS PED OPN 6 11 REMOTE CODE ENABLED Selects remote transmitter coding function Off On On 6 12 ACTIVITY REPORTS Select report to be output Off 255 Off 1 6 13 ACTIVITY R...

Страница 31: ...e date and day are displayed and set Fig 46 NOTE The time is in a 24 hour format and the Day of the week is not automatically set with the date To change the settings simply press UP or DOWN to display the cursor and then move to the field to be changed using the NEXT PREV buttons Then press OPEN CLOSE to change the setting and then the SET or STOP buttons to save Menu 7 2 View Programs Select this...

Страница 32: ...sub menus are available Run Programs The programs of the timer can be interrupted by selecting RUN PROGRAM off Configuration Of GPI Input General Purpose Input can be configured as OSC PED or DST setup This is activated by the GPI input terminal with the N O switch When GPI Selected As OSC If the door is moving the activation of GPI input or pressing a transmitter button with the OSC function assign...

Страница 33: ...ener will then beep each time a transmission is received If the transmitter button is stored in the controller memory and has a function assigned to it a second screen will be displayed that shows the transmitter details along with the button pressed Fig 52 The example shows the case where transmitter number 14 is activated by button 4 Note ID is selected for display Menu 8 3 Display History The o...

Страница 34: ... Cycles 2 Close Cycles 3 PED Cycles 4 Setup Limits 5 Warranty Cycles 6 Open O LS 7 Close O LS 8 Open Stalls 9 Close Stalls 10 Direction Faults 11 Position Sensor faults 12 Drive Memory Faults 13 Position Wrap Faults 14 Console Volt Faults 15 PCB Temp Fault 16 Comms Compat Faults 17 INV logic faults 18 Low DC Bus Volt Faults Menu 8 7 Install Data Open Position Shows the fully open position door cou...

Страница 35: ...s memory Once selected the PREV or NEXT buttons can be used to view the Memory Tool options To execute the displayed option simply press SET Menu 9 1 Clear Control This option will clear the door control memory and reload the factory set defaults for parameters such as the lock time light time Auto Close times etc It will also clear the travel limits Menu 9 2 Clear Tx ers This option will clear th...

Страница 36: ...des Receiver Sensitivity 103 dB Transmitter frequency UHF Multi frequency FM Transmitter Coding type Code hopping Number of code combinations Over 4 29 billion random codes Code generation Non linear encryption algorithm Courtesy light Common Collector Transistor output Controller fuse 10 A slow blow Transmitter Battery CR 2032 3 Volts Real Time Clock Battery CR 1220 1 5 Volts NOTE 1 The door must...

Страница 37: ...it OPEN CLOSE button but not from transmitter Transmitter code not stored in memory Transmitters operation disabled from the time clock The opener is in Vacation Mode Code transmitter in to openers memory Enable the transmitter operation in the time clock menu Turn off Vacation Mode Flat battery Replace battery Door does not close with transmitter Safety Close Mode is on PE Beams not installed or ...

Страница 38: ... does not operate smoothly call your shutter door professional Yearly Automatic Technology suggests you contact your shutter door professional to perform an annual door service CAUTION Frequently examine the shutter door particularly springs and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a fault in the installation or an incorrectly balanced ...

Страница 39: ...Owner Installation Instructions Axess Pro Series 3000 39 Spare Parts ...

Страница 40: ...n a proper working order as per clauses d through h j installation adjustment or use which is not in accordance with the instructions set out in installation instruction manual k attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs l faulty or unsuitable wiring of structure ...

Страница 41: ...arks of Automatic Technology Australia Pty Ltd No part of this document may be reproduced without prior permission In an ongoing commitment to product quality we reserve the right to change specification without notice E OE Automatic Technololgy Australia Pty Ltd ABN 11 007 125 368 6 8 Fiveways Boulevard Keysborough Victoria 3173 Australia P 1300 133 944 61 3 9791 0200 International Enquiries Only ...

Отзывы: