p 11/58
Technical Manual NAM-BL4x-MT-EN-C
The information in this document is the property of Automatic Systems and is confidential. The consignee withholds from using it for anything other than the use of the products or the execution of the
project to which they belong and withholds from communicating it to third parties without prior written agreement from Automatic Systems. Document subject to change without prior notice.
The control board is the interface between the user and the barrier. It manages all of the latter’s actions,
including any potential options. The navigation of the display menus is based on an architecture using drop-
down menus with three levels: MENUS
PARAMETERS
VALUES.
Use the
◄►
keys to move from one level to another (hold down for a few seconds to move from the standby
screen to another menu). Use the
▲▼
keys to navigate within the levels themselves. Press the
OK
key to
validate a value modification.
Note
: The second column in the tables below provides the factory settings of the parameter values as they
are entered during manufacturing of the control board.
Nevertheless, as each piece of equipment has been specifically adjusted in our workshops, the values
actually present on the board may differ slightly.
Note:
Below only the simplified menus are presented, which are sufficient for everyday use of the barrier.
Please refer to the control board manual (available upon request) for a detailed description of all of the
functions, adjusting their parameters, etc.
The menus are displayed on the
first line, in capital letters and
from the first character of the
LCD.
Press
▲
or
▼
for a few seconds
to leave the PRDSTD screen
and access other menus.
Only the first letter of each word in
the parameters is a capital.
Parameters are displayed on the
top line starting with the second
character of the LCD (i.e., there is
a space in front). At the end of the
first line the parameter unit
appears, if there is one.
The question mark (?) preceding the
parameter indicates that the latter is
ready to be modified.
The current value of the parameter
appears on the second line.
The asterisk (*) under a parameter
indicates that it is the factory setting.
The modification is validated by
pressing the OK key.
Save the modifications in
order to avoid losing them
during power outages (QUICK
START
►
Memory
►
Save.
Menus
Parameters
Arm Length
Barrier Type
Arm Type
? Arm Length
* 3m00
? Arm Length
2m50
? Arm Length
2m00
? Arm Length
6m00
? Arm Length
3m50
? Arm Length
4m00
? Arm Length
4m50
? Arm Length
5m50
? Arm Length
5m00
CANCEL
VALIDATE OK
or
Values
QUICK START
PRDSTD - BL_xxx
DATE & TIME
CL REGULATION
TIMING
OUTPUT FUNCTION
SENSOR FUNCTION