background image

SELF INSTALL - NEED TECHNICAL

ASSISTANCE?

OPTION 1: DIRECT WITH THE SERVICE DESK – QUICKEST AND MOST EFFECTIVE METHOD

Submit your enquiry direct with the service desk at –

[email protected]

The service desk has the most experienced staff in Australia to help with your problem but they need your help.

Describe your problem in detail and as clearly as possible. Don’t forget to include a telephone number.

Be certain to detail which model or models of you are working with.

Send photos of the installation – they love photos. The people at the service desk are good but they are

even better when they can see the installation. Send photos of the overall scene so they can see the

entire installation. Also send photos of the wiring to the control board and any other part of the

installation you think is relevant.

Send video if appropriate. Smartphone’s these days take remarkably good video in small file sizes which

can be emailed in a moment. If your problem needs a video to show the issue please feel free to send it.

NOTE: THIS IS BY FAR THE FASTEST AND MOST SUCCESFUL WAY TO SOLVE YOUR PROBLEM

PHOTOS AND VIDEOS ARE THE NEXT BEST THING TO BEING THERE

OPTION 2: LODGE YOUR ENQUIRY LOCALLY - SLOWER BUT CAN STILL BE EFFECTIVE

Make contact with the store of purchase. Branch staffs are typically not technicians and dependent on their length

of service will have varying degrees of technical knowledge. If they cannot help however they will certainly either

source help locally from their technicians or make contact with the service technicians on your behalf.

OPTION 3: SERVICE CALL WITH AUTOMATIC SOLUTIONS TECHNICIAN – SLOWEST METHOD

If you fall within the local branch service area it may be possible to book a local technician to look at your

installation. Wait times will vary dependent on local workloads. The cost is a service fee which includes the first

half hour and the hourly rate thereafter. If any Automatic Solutions provided parts are found to be defective and

within warranty these will be provided free of charge.

(NOTE: If you suspect that any parts are defective and within warranty you may wish to consider option 4)

A note on this option: If you decide on this option you will be asked to sign an “authorisation to proceed” which

will provide legal authority and payment security. This form has three options available of which only the first two

are available to you. The third option is for warranty repairs only for full install customers. Self install customers

requiring warranty only service need to refer to option four below.

IMPORTANT: IN SHORT THIS OPTION WILL INCUR CHAR

GES

OPTION 4: RETURN THE PRODUCT IF BELIEVED TO BE FAULTY

As a self install customer who has purchased product if you believe the product to be faulty rather than an

installation or site problem you have the option of returning the product for evaluation and to exercise your right

to a replacement, repair or refund as applicable. All returned product is forwarded immediately to the service

technicians for evaluation and response. There are two main methods available to return product –

Direct to the service centre – this is the quickest method as it cuts out the branch delay

Via the branch of purchase – slower because of the delay at the branch

When choosing this option you need to complete a product return form. This form gives you all the information

on procedure involved and where to send to.  These are available at the branch of purchase, can be emailed to

you (contact your branch), or available here -

http://automaticsolutions.com.au/page/warranty.php

Содержание AB

Страница 1: ...P a g e 1 Installation User Manual For C e l l C O M GSM Intercom System Models AB ABK HB HBK FB FBK Version 6 ...

Страница 2: ...SM controller Pg 5 Codelock Keypad Connections Pg 5 Wiring Tips Pg 6 Powering Up Pg 6 Programming Pg 7 Complete list of GSM parameters Pg 9 Keypad Overview Pg 10 Basic Keypad Programming Pg 10 Full Keypad Programming Pg 10 Using the Keypad Pg 12 Using the Intercom Pg 12 Control by SMS Pg 13 Check if door gate is open closed Pg 13 Using optional App Pg 13 Maintenance of the intercom Pg 14 Troublesh...

Страница 3: ...ets and will not work in the unit Power TIP Most technical calls received are due to installers using CAT5 or alarm cable to power the unit Neither are rated to carry enough power 1 2 amp peak Please use following cable Up to 2 metres 6 feet Use minimum 0 75mm2 18 gauge Up to 4 metres 12 feet Use minimum 1mm2 16 gauge Up to 8 metres 24 feet Use minimum 1 5mm2 14 gauge Using insufficient power cabl...

Страница 4: ...ide View Flush Panels Call Button Optional keypad module Remove Side View Flush with surface Tip Use appropriate fixings to ensure the intercom cannot be removed from the wall Do not remove the protective film until the system is fully installed and working Protective coverings are there to protect the intercom from scratches and marks during installation Antenna height is best higher than interco...

Страница 5: ...Codelock Keypad connections Keypad versions only N C COM N O N C COM N O egress OUT1 OUT2 OUT3 N C COM N O K or A DU out GND Sense INT Lock Tamper N C O P1 inhib 12v from GSM unit Please ensure the SIM card is a 2G compatible SIM card The SIM may also be 3G and 4G capable as well as long as both the SIM and the network also support 2G Do not use a SIM card for a tablet as these only support data a...

Страница 6: ...GSM output Optional keypad output Lock Separate PSU Connecting automatic gates Start Com Gate controller GSM output Optional keypad output Powering Up Perform a final check of wiring and ensure the antenna is connected before switching on the power Once the power is switched on the power LED should illuminate GSM modem Power LED GSM LED CPU LED open close Searching Network found Standby Busy TIPS ...

Страница 7: ...987654321 Pass code Function code Data TIP 11 Telephone number 1 12 Telephone number 2 13 Telephone number 3 E g 12 1234 11telephonenumber1 12telephonenumber2 13telephonenumber3 Send the SMS 20 as shown to the SIM card number of the intercom The unit should reply with a reception level between 1 and 31 20 Signal level 19 1 12 Poor 13 20 Medium 21 31 Good Note Reception levels below 14 can give pro...

Страница 8: ...stored in memory Any of these numbers can call the intercom It will recognise the number end the call without answering and activate the output relay all within a few seconds Now you may add numbers which can call the unit to trigger the relay by sending the following SMS up to 3 phone numbers can be sent in a single SMS 12 1234 72telephonenumber 72telephonenumber 72telephonenumber Just send the c...

Страница 9: ...king time 005 999 seconds Must be 3 digits 60 secs 55 Max monitoring time for listen in mode when calling the intercom 00 60 mins 00 no limit 10 mins Scheduled service calls 77number Store a service number to receive a scheduled call or SMS from the unit and prevent inactive SIM being turned off by provider N A 57 Set the time schedule for the intercom to make a scheduled call or SMS to the servic...

Страница 10: ... a security precaution the keypad cannot be programmed for 60 seconds Once this time elapses you may begin TIP Flashing amber LED is normal standby mode Basic Keypad Programming 0 0 0 0 Quick start guide 1 Enter programming mode amber LED should be ON 1 0 2 0 0 0 2 Enter a new user code 3 Exit programming mode 4 Enter the new user code to check the relay clicks Full Keypad programming Enter progra...

Страница 11: ... code 4 8 digits Validate Example Add user 31 to have access code 5555 operating relay 2 2 0 2 0 3 5 5 5 5 1 Group 2 Add code Location 31 Pin code 5555 Validate Programming relay output times and modes 0 1 0 start stop toggle mode latching 1 99999 seconds momentary operation 9 9 9 9 9 or 51 relay1 52 relay2 53 relay3 Validate Delete a user code even if you don t know the code 5 10 relay1 20 relay2...

Страница 12: ...ited out of programming mode simply enter the user code Using super user codes 1 Activate output 1 2 Activate output 2 3 Activate output 3 Using the intercom This cellular intercom can dial up to 4 numbers in sequence for any call button when pressed Any user receiving the call can answer speak to the visitor and press the following digits on their mobile or fixed line telephone to control the rel...

Страница 13: ... example shows that the input sensor is in OPEN state and the relay is OFF If the relay is latched then the status will change to ON If the input limit witch is closed the status shown will change to CLOSED TIP If there is not a physical limit switch fitted to the door or gate then the status input will always show OPEN 22 Status OPEN Relay OFF Trigger Gates Hold Open Unhold Close Main Trigger but...

Страница 14: ...and standards 850 900 1800 1900 MHz Check the reception is good Poor reception is not sufficient Check that the cable from power supply to intercom is less than 15 feet and that the cable thickness is 1 5mm or 14 gauge if longer than 15 feet Alarm or CAT5 cable is not sufficient Power off remove the SIM use fine sand paper to lightly sand the SIM pads and contacts on the GSM unit lightly bend the ...

Страница 15: ...tly is also a symptom of low reception or insufficient power cabling Check steps above on improving reception or addressing the power problem Some iphone users may experience trouble using the key to trigger the gates In this case refer to your distributor on how to change the trigger key to any other key Also check that the relays are not already latched with the 22 command If they are latched th...

Страница 16: ...P a g e 16 ...

Страница 17: ...service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local workloads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defec...