Function List
The following is a complete list of the available functions. Functions are detailed on the following pages.
Function
Number
Function Name
Function Description
1
restart_function
Same as Dispense / Reset Button on front panel.
2
display_last_error Shows the code for the last error that occurred.
3
weigh_disable
Toggles the Weighing Cycle on and off.
4
tare_function
Sets the default zero to the current A/D value. Make sure the
Accumulator Doors are empty.
5
calibrate
Accepts a 1 lb./16oz (450gm) reference weight; sets the .75 lb./12 oz.
(350 gm), 1.0 lb/16 oz. (450 gm) and 1.5 lb./24 oz. (750 gm) targets.
6
adjust_Pos1_up
Adjusts selector switch position #1 (.75 lb./12 oz./350 gm) target
upward in increments of 1 oz. (25 gm).
7
adjust_Pos1_dn
Adjusts selector switch position #1 (.75 lb./12 oz./350 gm) target
downward in increments of 1 oz. (25 gm)
8
adjust_Pos2_up
Adjusts selector switch position #2 (1 lb./16 oz./450 gm) target upward
in increments of 1 oz. (25 gm).
9
adjust_Pos2_dn
Adjusts selector switch position #2 (1 lb./16 oz./450 gm) target
downward in increments of 1 oz. (25 gm)
10
adjust_Pos3_up
Adjusts selector switch position #3 (1.5 lb./24 oz./750 gm) target
upward in increments of 1 oz. (25 gm)
11
adjust_Pos3_dn
Adjusts selector switch position #3 (1.5 lb./24 oz./750 gm) target
downward in increments of 1 oz. (25 gm)
12
watchdog test
Locks up the program so that the watchdog timer fires. Invokes error
#2.
13
load_cell_readout Displays the current reading from the Load Cell (live display,
uncalibrated).
14
actuate_Doors
Opens and closes the Accumulator Doors.
15
actuate_Drum
Turns the Drum Motor on and off.
16
actuate_lights
Turns the control panel lights on and off.
17
restore_defaults
Clears the error log and sets default weighing parameters.
18
clear_errors
Clears the error log.
19
error_counts
Displays the error log.
20
parameters
Displays the default weighing parameters.
21
set units
Sets weighing units to ounces “US”, or grams “In” International.
22
exercise mode
Enables exercise mode, all subsystems cycle.
23
rev
Displays revision level of installed EPROM
Содержание McDonald's DF22
Страница 28: ...DF22 Dispenser Copyright 2005 Automated Equipment LLC All Rights Reserved 28 ACCUMULATOR ASSEMBLY...
Страница 31: ...DF22 Dispenser Copyright 2005 Automated Equipment LLC All Rights Reserved 31 Electrical Schematic...
Страница 37: ...DF22 Dispenser Copyright 2005 Automated Equipment LLC All Rights Reserved 37 NOTES...