![AUTOK TC818 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/autok/tc818/tc818_instruction-manual_3021410030.webp)
Tension Controller TC818
5.4 Constant tension control
5.4.1 Automatic mode
5.4.2 Manual mode
5.4.3 Debug steps
Alter the setting tension using the
Inc/Dec
key or digital knob
Measured radius
Output
RadiTension
Rad
:
350mm
SV.
:
25.0kg
Out
:
28.5 %
Man Monitor
Rad
:
350mm
SV.
:
25.0kg
Out
:
30.5 %
Alter the output using the
Inc/Dec
key or digital knob
Measured radius
1. Make sure that the mounting and connection of the proximity switch/encoder is correct, and check if the
proximity switch/encoder works correctly.
2. Set proper values for the constant tension control related parameters.
(1). Set
Function[29]
to
Radius control
.
Set
Ctrl Mode[30]
to
Constant ctrl
.
Set
Count Mode[32]
to
Thick Sum
or
Ratio
.
(2). Set proper values for the radius measurement parameters, see
5.2 Roll radius monitoring
.
(3). Set
Torque[39]
according to the actual brake/clutch.
(4). Set proper values for parameters 08-15.
3. Operate in manual mode to test if the measurement of the radius is correct, if not, goto step 2.
4. Adjust the output manually, after the tension of the web is stable, switch to automatic mode, the controller
will smooth the transition automatically.
Note: When switching from automatic mode to manual mode, the controller will smooth the transition
automatically.
28