background image

AIR6V 

01

 

AIR6V 

01

 

AIR6V 

01

 

AUTOJACK GUARANTEE 

 

2.2

 

Any issues with the product resulting in a 

potential claim under the guarantee must be 
reported to the Authorised Dealer from which it 
was purchased within 48 hours of receipt. 

2.3

 

If the authorised Dealer who supplied the 

product to you has been unable to satisfy your 
query, any claims made under this guarantee 
should be made directly to Autojack. The claim 
itself should be made in a letter setting out the 
date and place of purchase, giving a brief 
explanation of the problem which has led to the 
claim. This letter should be then sent with proof 
of purchase to Autojack. If you include a contact 
number with this it will speed your claim up. 

2.4

 

Please note that it is essential that the letter 

of claim reaches Autojack on the last day of this 
guarantee at the latest. Late claims will not be 
considered. 

3.

 

Limitation of Liability. 

 

3.1

 

We only supply products for domestic and 

private use. You agree not to use the product for 
any commercial, business or resale purposes and 
we have no liability to you for any loss of profit, 
loss of business, business interruption or loss of 
business opportunity. 

AIR24L

 

14

 

3.2 This guarantee does not confer any rights 
other than these expressly set out above and does 
not cover any claims for consequential loss or 
damage. This guarantee is offered as an extra 
benefit and does not affect your statutory rights as 
a consumer. 

4. Notice 

 

This guarantee applies to all product purchased 

from an Authorised Dealer of Autojack within the 

United Kingdom. Terms of guarantee may vary in 

other countries. 

Содержание AIR24L

Страница 1: ...24 Litre Direct Drive Air Compressor AIR24L ORIGINAL INSTRUCTIONS SAFETY AND OPERATING MANUAL AIR24L...

Страница 2: ...ormity 15 Parts list 16 Parts Diagram 18 TABLE OF CONTENTS Welcome to Autojack Dear customer Congratulations on your purchase Before using the Product for the first time please be sure to read these i...

Страница 3: ...ever use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When opera...

Страница 4: ...ety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow personsunfamiliar with the power tool or these instructions...

Страница 5: ...maging to your health 7 8 Use in a well ventilated area 7 9 Ensure that the work area is at least 7 10 Do not use materials such as white spirits Butyl Alcohol and methylene chloride with the PVC hose...

Страница 6: ...and damage before each use Do not use if found to be damaged 9 Using an Extension Cable 9 1 If an extension cable is required use an approved triple core extension cable suitable for the power input...

Страница 7: ...can cause damage to hearing Caution Wear safety goggles Danger Read the operating instructions to reduce the risk of injury Amperes 7 5M 15M 25M 30M 45M 60M 0 2 0 6 6 6 6 6 6 2 1 3 4 6 6 6 6 6 6 3 5 5...

Страница 8: ...ve 24Litre tank Intended Use Designed to generate compressed air Using equipment in ways other than its intended use the user and not the manufacture will be liable for any damage or injuries caused A...

Страница 9: ...MACHINE DETAILS AND PRODUCT FEATURES AIR24L 07...

Страница 10: ...MACHINE DETAILS AND PRODUCT FEATURES AIR24L 08...

Страница 11: ...be used in rooms with good ventilation and temperature of 0 to 40 C 1 8 Ensure there is no dust acid vapors explosive gasses or inflammable gases in the room 2 Product assembly 2 1 Fitting wheels Fit...

Страница 12: ...to increase pressure and anti clockwise to decrease Adjusting the pressure To switch on the compressor pull out the knob 8 To switch off the compressor press the knob 8 back in Figure 2 Setting the pr...

Страница 13: ...l after use connect an air tool and run in idle mode until excess pressure has dissipated Maintenance and service Pull out plug before performing any cleaning or maintenance work Wait for the equipmen...

Страница 14: ...in compressor 3 Piston knocking valve seat 4 Moving parts seriously worn 1 Check and retighten 2 Check and clean away 3 Replace with thicker paper gasket 4 Repair or replace Pressure insufficient or d...

Страница 15: ...lectrical connection misuse alteration or repair of the product without approval 1 2 5 The product has been used in a domestic environment only 1 2 6 The fault does not relate to consumable items such...

Страница 16: ...im up 2 4 Please note that it is essential that the letter of claim reaches Autojack on the last day of this guarantee at the latest Late claims will not be considered 3 Limitation of Liability 3 1 We...

Страница 17: ...ive Air Compressor AIR24L Is in compliance with the regulations included in theDirectives 2006 42 EC EC DECLARATION OF CONFORMITY Certificate for EC type examination delivered by Interk Testing Servic...

Страница 18: ...ressure pipe screw 14 Release pipe screw 45 Connector 15 Release pipe 46 Washer 16 Cable 47 Spring 17 Safety valve 48 Cylinder head screw 18 Pressure switch 49 Air filter 20 Connector 50 Seal ring 21...

Страница 19: ...Description 62 Piston pin 68 Oil baffle plate 63 Inside calliper 69 Breathe plug 64 Connection rod 70 Front cover 65 Crank 71 Front cover screw 66 Screw 72 Oil leveler 67 Crank screw 73 Hand hole Par...

Страница 20: ...Parts Diagram AIR24L 18...

Отзывы: