Autogard AG/500 Скачать руководство пользователя страница 8

Operation instructions for road gates AG/500, AG/900, AG/M1 

© Autogard spol. s r.o. 2004

8

Control unit AGN2.0 / AGN2.1

Barriers of mod. AG500 a AG900 AGM1 are delivered with control unit AGN2.0 / AGN2.1 on
microprocessor basis which enable to adapt plug-in modules of radio receiver and loop detector.

Control unit AGN2.0 / AGN2.1– connection schema:

   Fuses:

fuse

Type

Value

F1

T

0,5 A

F2

T

5 A

F3

F

1 A

F4

T

2 A

Содержание AG/500

Страница 1: ...road gates AG 500 AG 900 AG M1 Operating instructions Manufactured by AUTOGARD spol s r o Dornych 47 617 00 Brno CZ tel 420 5 45 53 54 62 3 fax 420 5 45 53 54 65 e mail autogard autogard cz http www a...

Страница 2: ...and in alive area agree to specified technical norms General futures Automatic road gates AG 500 AG 900 AG M1 are driven by electric motor along with high torsion moment and belt driven equally dimen...

Страница 3: ...Operation instructions for road gates AG 500 AG 900 AG M1 Autogard spol s r o 2004 3 Outlet journal of AG 500...

Страница 4: ...Operation instructions for road gates AG 500 AG 900 AG M1 Autogard spol s r o 2004 4 Outlet journal of AG 900...

Страница 5: ...emales intended for the concreting The gate base make no a less then 600 mm power supply and signal cables brings cable guard including the cable from car detector loop like on the picture WARNING Pow...

Страница 6: ...e After the fixing of the gate column we finish the earthing of metallic gate column From the power supply cable 230V AC like CYKY 3x1 5 we affix the line wire PE to earth screw located on the right s...

Страница 7: ...of the rod and guarantee switch off the motor in last places of rod running The limit switches are located on the console near the gearbox Switching flags are attached with screws M5 imbus type on th...

Страница 8: ...AGN2 0 AGN2 1 Barriers of mod AG500 a AG900 AGM1 are delivered with control unit AGN2 0 AGN2 1 on microprocessor basis which enable to adapt plug in modules of radio receiver and loop detector Control...

Страница 9: ...O COM LIMIT Common pin for control inputs OPEN Input of NC contact of limit switch upper position CLOSE Input of NC contact of limit switch low position COM SAFE Common pin for control inputs FOTO Inp...

Страница 10: ...ic light driving 24V SEM input for external traffic light driving 24V Top side of control unit right part Output signal only AGN2 1 version max loading for each one is 24V 0 3A Pin Part Signal LM_UP X...

Страница 11: ...ts to move the opposite way During the closing cycle inputs FOTO and DET are tested If they are active the boom again stops and starts to move contrary Input STOP blocks all moves b new setting of con...

Страница 12: ...of switching traffic light on STOP Traffic light is switched by activation of any safety inputs when the car is nearby the barrier 00 traffic light is switched by command 01 external driving of traffi...

Страница 13: ...quency setting with the frequency switches several operationg frequencies per channel can be set in order to avoid couplings by nearby loops Two ore more detectors may not operate at the same frequenc...

Страница 14: ...ss system for public cash parking Accessories to request 9 inductive car detector 9 safety photocell 9 pneumatic skirting 9 flash light 9 rod flash light 9 radio control 9 sign STOP 9 full or half siz...

Страница 15: ...il 93 68 EEC The Decree of the Government No 169 1997 Coll as amended the Directive of the European Council 93 68 EEC The Decree of the Government No 170 1997 Coll as amended the Directive of the Euro...

Страница 16: ...Operation instructions for road gates AG 500 AG 900 AG M1 Autogard spol s r o 2004 16 Certificate...

Страница 17: ...Operation instructions for road gates AG 500 AG 900 AG M1 Autogard spol s r o 2004 17...

Страница 18: ...thing of road gate 6 Length of rods pulleys springs 6 The rod balancing with spring 7 Setting of limit switches 7 Emergency opening 7 Periodical adjustment 7 Control unit AGN2 0 AGN2 1 8 Loop detector...