a)
Start of control unit:
After connecting of power supply red LED in upper right corner is switched-on and in the line
of LED behind the plug-in module relative LED according the activated inputs.
Than the systém is in a
standard status
, lines on display are blinking.It means the barrier will
work normally.
Standard function:
In case the boom is in closed position the control unit waits for command OPEN - UP. This
can be made by following kinds : Push-button UP, Push-button Step-Step or by radio transmitter. If
during the opening an opposite command is given the boom stops for ca.1s and then starts to move
the opposite way. During the closing cycle inputs FOTO and DET are tested. If they are active, the
boom again stops and starts to move contrary. Input STOP blocks all moves.
b) new setting of control unit:
By simultanous pressing of both programming buttons
you can entry to the programming modus. Number of
programmable function is displayed on. This number can be
changed with the help of programming keys UP and DW. Choose
number of function, you want to change. By simultanous pressing
of both programming keys you can entry to the parameters
settings of this function. Values can be changed again with
programming keys UP and DW following the table of
programmable functions. After setting of required values they are
saved by simultanous pressing of both keys and control unit returns to standard status (lines are
blinking ). When changing other parameters repeate the same way.