3. APPLICATION AREA, STATION SPECIFICATIONS

Charging mode under IEC61851-1

Type 1, Type 2

Nominal input voltage

3 phases 380V

Input voltage deviation 

limits, %, max

+-10

Nominal mains frequency

50 Hz

Main ports:
Type 1 (SAE-J1772)

Type 2 (Mennekes)

1 p. 

Output power of the port 7,4 kWh

Current- 32А

1 p.
Output power of the port  - 22 kWh

Current - 32 А

Type 1 + Type 2 Charging Stations Specifications

3.1    APPLICATION AREA

The charger is designed exclusively for charging electric vehicles.

For information about the materials, please contact 

AutoEnterprise

 sales 

representative  or contact the 

AutoEnterprise

 technical support team.

The following sections should also be followed as part of the intended use:

•   

Only charge compatible electric vehicles.

•   

Failure to follow the instructions for use, maintenance and repair described in these 

operating instructions excludes any liability on the part of the manufacturer in the event of 

a defect.

•   

The system must only be operated, maintained and repaired by personnel familiar with 

the intended use and hazards!

•   

Carry out maintenance and repairs according to the specifications in this manual.

•   

The unit may only be operated with equipment and spare parts supplied or listed in the 

spare parts and consumables lists.

•   

Using the charger in other areas is contrary to its intended purpose. The manufacturer is 

not responsible for any damage to the equipment resulting from such use. The user is solely 

responsible for any damage resulting from improper use of the system.

Содержание COMMERCIAL 2

Страница 1: ...COMMERCIAL 2 Instruction manual...

Страница 2: ...hers without our written permission Any violation of the law will be prosecuted AutoEnterprise cannot be held liable for any direct or indirect damages resulting from the use or operation of the elect...

Страница 3: ...anty 5 2 4 Disposal information 6 2 5 Manufacturer s label 6 3 Application area technical specifications 7 3 1 Application area 7 3 2 technical specifications 7 3 3 Equipment modifications 9 3 4 Gener...

Страница 4: ...h This symbol indicates instructions that must be followed to avoid injury trauma or death COMMERCIAL 2 is a high quality charging station hereinafter referred to as the station which is made using th...

Страница 5: ...uent damages or consequential damages Strict adherence to the safety procedures described in these operating instructions and special care when using the equipment are essential to prevent and reduce...

Страница 6: ...acturer located on the front panel of the station and consists of 4 digits The station s factory number is specified in the shipping documents and is also located within the station on a GSM modem par...

Страница 7: ...llowing sections should also be followed as part of the intended use Only charge compatible electric vehicles Failure to follow the instructions for use maintenance and repair described in these opera...

Страница 8: ...rrent adjustment Yes Possibility to manage rates of the station Yes Single body version Yes CHARGING STATION FEATURES Signs labels and pictograms attached to the station must be visible Type 1 Type 1...

Страница 9: ...an result in injury and damage to or destruction of the product Ignoring the safety recommendations and instructions in this manual will relieve the manufacturer and his authorized representatives of...

Страница 10: ...e station is structurally designed as a monoblock mounted on a stand and has the following control and management bodies Charging station in the case on a stand optional without a stand 1 pc connector...

Страница 11: ...e charging station with the utmost care Transport the charger as carefully as possible to avoid damaging it Protect the charger from damage during transportation by using belts and inserts and leave s...

Страница 12: ...devices We recommend installing a suitable 3 pole circuit breaker for a current of 80 A The minimum cross section of each lead wire should be at least 16 mm the lead material should be copper twisted...

Страница 13: ...ower cable must be connected to the AC mains using external switching devices The charging station operation modes are presented on the LCD display which among other things displays the following info...

Страница 14: ...ied out Visual inspection for overheating of equipment check pulling connections Identification of defective parts and assemblies maintenance and replacement Authorized service personnel must disconne...

Страница 15: ...on of the GSM signal or the replacement of the antenna for a more powerful with a stifter Damage to the socket Physical wear and tear careless handling of equipment Disconnect the device If the cable...

Страница 16: ...N MANUAL COMMERCIAL 2 CHARGING STATION 16 TECH SUPPORT Contacts 1 You can write an email to tech support using the contact page on our web site 2 You can call on numbers listed on the web site AUTOENT...

Отзывы: