Auto Meter XTC-160OZR Скачать руководство пользователя страница 4

4

21

CONTENTS

ABOUT MENU

XTC-160OZR

VERSION 2.12

SN : 10001

COPYRIGHT 2012

T#10 12V BATT.

POSSIBLE BAD CON

'Y' TO CONTINUE

T#10 12V BATT.

DISCONNECTED!!

'Y' TO CONTINUE

T#10 12V BATT.

ABORTED!!

'Y' TO CONTINUE

DEEP DISCHARGE

MOVE TO SLOW

CHARGER

'Y' TO CONTINUE

T#10 12V BATT.

POWER PROBLEM

'Y' TO CONTINUE

 REVIEW/PRINT 
 SETUP 
 USE USB DRIVE 
>ABOUT

Press 'N' to return to the 

main menu.

This is due to a bad connection. 

Check the battery connection.

Clean terminals of any corrosion.

Clean clamps.

The clamps disconnected during 

charging. Check connection.

Clean terminals of any corrosion.

Clean clamps.

Battery is so discharged it is 

drawing more current than the 

XTC-160 can safely provide.  Place 

battery on a slow charger.

There is a problem with the AC 

power.  (Brown out, circuit breaker 

opened, unit accidently shut off.)

Charge was aborted by the 

operator.

Select ABOUT from the main menu. The following is displayed.

Error Messages

Specifications ............................................................................. 3 

Safety ......................................................................................... 5 

Cause of Battery Failure ............................................................. 5 

Inspection and Visual Check ...................................................... 6 

What to Expect ........................................................................... 7 

Controls and Functions............................................................... 8 

Hook-Up ..................................................................................... 9 

Battery Test and Charge Sequence .....................................10-12 

Charge Only Sequence .......................................................13-14 

Test Only Sequence ............................................................15-16

Test Results .............................................................................. 17 

Setup ........................................................................................ 18 

Printer Operation ...................................................................... 19 

Review Tests ............................................................................ 19 

Using USB Drive....................................................................... 20 

About Menu .............................................................................. 21 

Care and Maintenance ............................................................. 22 

Contact Information .................................................................. 24

Содержание XTC-160OZR

Страница 1: ...0OZR is the ultimate load tester and battery charger with fast and accurate automated testing and charging for the professional 2650 1741 00 10 8 13 T est Equipment Auto Meter Products Inc 413 West El...

Страница 2: ...eads the voltage and the other jaw connects to the larger conducting wire that draws the load in each test Electrical isolation between jaws is necessary for accurate readings For side terminal batter...

Страница 3: ...ce 5 to 30 min larger discharged batteries longer CCA Range 100 1600 LCD Backlit 1 x 2 5 4 line x 16 characters Cooling 5 Internal Fan Battery Temperature Measurement Infrared IR Temperature Probe Hol...

Страница 4: ...terminals of any corrosion Clean clamps Battery is so discharged it is drawing more current than the XTC 160 can safely provide Place battery on a slow charger There is a problem with the AC power Bro...

Страница 5: ...trolytic fluid and corrosion on battery connections can greatly reduce battery life and affect battery performance Age of Battery If the date code on the battery indicates it is fairly old the failure...

Страница 6: ...spect Battery for terminal corrosion loose or broken posts cracks in the case moisture and dirt around the terminals Important Note A damaged battery must be replaced before proceeding From the menu s...

Страница 7: ...e maximum time remaining to bring the battery to a full charge The LCD screen makes it possible to view the XTC 160OZR testing and charging status fully unattended The LCD provides easy menu instructi...

Страница 8: ...screens will be displayed Battery passes testing Return to service Charge battery and place into service Test Only Battery did not have a sufficient charge for a Digital Pulse Load Test Charge require...

Страница 9: ...NECTIONS CHECK BATTERY CONNECTIONS Y TO CONTINUE Adjust the rating using the Up and Down keys Press Y to Enter and begin the test If OTHER brand was selected the battery rating type is needed Use the...

Страница 10: ...TO CHARGE SAFELY Y TO CONTINUE TEST CHARGE TEST ONLY CHARGE ONLY REVIEW PRINT The unit will go back to main menu Use the Up and Down keys to move the cursor The options are Super Start Optima and Othe...

Страница 11: ...ttery categories the battery type is needed Use the Up or Down keys move the cursor Press Y to select Press N to go back to the Battery Category screen For marine batteries the battery function type i...

Страница 12: ...TIME 10 MIN N TO STOP If the battery temperature goes over 140 F charging will stop If no temperature probe is connected use the Up and Down keys to enter the current battery temp The Up Down keys in...