AUTOMATED CONDITIONS

If the battery needs charging the XTC-160OZR will automatically charge the battery and then 

run a Load Test. The LED indicators will show the status during a fully automated Test and 

Charge sequence. This makes it possible to view the status and final results at a distance.

  Red "TESTING" light indicates battery 

is being tested.

  Red "CHARGING" light indicates 

battery is being charged. .

  Green "GOOD" light indicates battery is good. 

  Green "GOOD" with Red 

"CHARGING" light indicates battery is 

being charged. .

  Green "GOOD" with Green 

"CHARGED" light indicates battery is 

good and has been charged.

  Yellow See Display indicates that some 

condition occurred that did not let the 

battery charge or that the battery is Good, 

Last Quarter of Life. See the display for 

details.

  Red "BAD" indicates the battery is too 

bad to charge or is considered bad 

after a charge is attempted.

TEST and CHARGE SEQUENCE cont

LCD TEST RESULTS:

 Include 

"GOOD BATTERY" "GOOD, IN LAST 

QUARTER OF LIFE" and "BAD 

BATTERY".

#290 12V BATT. 

GOOD BATTERY

'Y' TO PRINT

Press 'Y' to print results on printer.

See page 17 for results.

CHARGING 

MAX TIME: 10 MIN

 

'N' TO STOP

If the battery temperature goes over 140°F charging will stop.

If no temperature probe is connected use the (+Up) and (-Down) keys to enter the current battery temp. 

The (Up) & (Down) keys increment & decrement in units of 10. Press ‘Y’ to begin. If temperature probe is 

connected, the unit will automatically measure the temperature of the battery.

CHARGE ONLY SEQUENCE 

From the menu select CHARGE ONLY using the +/- keys.

Then press ‘Y’ Enter to enter.

>ENTER BATTERY 

 TEMP. 70F 

 USE +/- 12.56V

 'Y' TO CONTINUE

The unit will go back to main 

menu.

THE BATTERY 

NEEDS TO COOL

BEFORE CHARGING 

'Y' TO CONTINUE

THE BATTERY 

IS TOO HOT TO 

CHARGE SAFELY 

'Y' TO CONTINUE

If the battery temperature is above 120° the following message will appear

 TEST & CHARGE 

 TEST ONLY

>CHARGE ONLY  

 REVIEW/PRINT

 BATTERY BRAND?

>SUPER START

 OPTIMA

 OTHER

Use the (+Up) and (-Down) keys to 

move the cursor. The options are: 

Super Start, Optima, and Other. 

Press 'Y' to select.

 BATT. CATEGORY?

>ECONOMY

 EXTREME

 PLATINUM

Use the (+Up) and (-Down) keys to move the 

cursor. This list will vary depending on the 

battery brand selected. Press 'Y' to select. 

'N' will go back to brand screen.

Economy

Extreme

Platinum

Premium

Super Start

Commercial 

Lawn & Garden

Marine

Power Sport

Red

Yellow

Blue

Optima

Other

Marine

Power Sport

Starting

Commercial

Lawn & Garden

Содержание XTC-160OZR

Страница 1: ...0OZR is the ultimate load tester and battery charger with fast and accurate automated testing and charging for the professional 2650 1741 00 10 8 13 T est Equipment Auto Meter Products Inc 413 West El...

Страница 2: ...eads the voltage and the other jaw connects to the larger conducting wire that draws the load in each test Electrical isolation between jaws is necessary for accurate readings For side terminal batter...

Страница 3: ...ce 5 to 30 min larger discharged batteries longer CCA Range 100 1600 LCD Backlit 1 x 2 5 4 line x 16 characters Cooling 5 Internal Fan Battery Temperature Measurement Infrared IR Temperature Probe Hol...

Страница 4: ...terminals of any corrosion Clean clamps Battery is so discharged it is drawing more current than the XTC 160 can safely provide Place battery on a slow charger There is a problem with the AC power Bro...

Страница 5: ...trolytic fluid and corrosion on battery connections can greatly reduce battery life and affect battery performance Age of Battery If the date code on the battery indicates it is fairly old the failure...

Страница 6: ...spect Battery for terminal corrosion loose or broken posts cracks in the case moisture and dirt around the terminals Important Note A damaged battery must be replaced before proceeding From the menu s...

Страница 7: ...e maximum time remaining to bring the battery to a full charge The LCD screen makes it possible to view the XTC 160OZR testing and charging status fully unattended The LCD provides easy menu instructi...

Страница 8: ...screens will be displayed Battery passes testing Return to service Charge battery and place into service Test Only Battery did not have a sufficient charge for a Digital Pulse Load Test Charge require...

Страница 9: ...NECTIONS CHECK BATTERY CONNECTIONS Y TO CONTINUE Adjust the rating using the Up and Down keys Press Y to Enter and begin the test If OTHER brand was selected the battery rating type is needed Use the...

Страница 10: ...TO CHARGE SAFELY Y TO CONTINUE TEST CHARGE TEST ONLY CHARGE ONLY REVIEW PRINT The unit will go back to main menu Use the Up and Down keys to move the cursor The options are Super Start Optima and Othe...

Страница 11: ...ttery categories the battery type is needed Use the Up or Down keys move the cursor Press Y to select Press N to go back to the Battery Category screen For marine batteries the battery function type i...

Страница 12: ...TIME 10 MIN N TO STOP If the battery temperature goes over 140 F charging will stop If no temperature probe is connected use the Up and Down keys to enter the current battery temp The Up Down keys in...

Отзывы: