FEATURES
10mA high resolution on 40A DC/AC range.
Temperature (Degrees C or F)
and Capacitance
One touch zero for DCA adjustment.
Auto-range for V, A,
Ω
, F, and temperature
Frequency (Hz).
23 mm diameter jaw.
Fast bar graph display (30 times/sec.) for transient observation.
Continuity and frequency measurements.
Max/Min and Data Hold functions.
600V overload protection for ohm measurement.
Ideal for working in crowded switch box or cable areas.
CONTROLS AND FUNCTIONS
1.
Transformer Jaw
is used to pick up current signal. It measures DC/AC
current. The jaw must enclose the conducting wire.
2.
Transformer Trigger
is used to open the jaw.
3.
Function Selector Switch
is used to select the function such as DCA,
ACA, DCV, ACV, Hz, Ohm and Continuity.
4.
AC/DC
select switch. This is used to select AC or DC voltage or
current, Hz or Duty, Ohm or Continuity, Capacitance or Diode, °F or °C.
5.
Data Hold Button
holds the LCD reading when pushed
.
Press again
to release it. This button is not available in continuity or diode function.
6.
Max/Min Hold Button.
This button is used to enable the maximum
or minimum value to be displayed and updated during measurement.
Press once, minimum value shall be display and updated. Press again,
maximum value shall be displayed and updated. Zero function will be
disabled if MAX/MIN is enabled. This button is not available in Duty,
Hz, Continuity, Diode or Capacitance function.
SPECIFICATIONS CONTINUED
4
17
TEMPERATURE (K Type Thermal Couple w/ Adapter, °C or °F):
Range
Resolution
Accuracy
Overload Protection
-40-0°C
0.1 °C
2.0% 2 °C
AC 600V
0-400°C
0.1 °C
0.5% 2°C
AC 600V
400-1000°C
1°C
0.5% 2 °C
AC 600V
-40-0°F
0.1°F
2.0% 4°F
AC 600V
0-400°F
0.1°F
0.5% 4°F
AC 600V
400-1800°F
1°F
0.5% 4°F
AC 600V
RESISTANCE (
Ω
):(open voltage 0.4V)
Range
Resolution
Accuracy
Overload Protection
400
Ω
0.1
Ω
1.5% 2dgts
AC 600V
4K
Ω
1
Ω
1.5% 2dgts
AC 600V
40K
Ω
10
Ω
1.5% 2dgts
AC 600V
400K
Ω
100
Ω
1.5% 2dgts
AC 600V
4M
Ω
1K
Ω
1.5% 2dgts
AC 600V
40M
Ω
10K
Ω
1.5% 2dgts
AC 600V
CONTINUITY (open voltage 0.4V, Overload Protection Ac600V)
Range
Resolution
Accuracy
Beeping
40-400
Ω
0.1
Ω
1.0% 2dgts
<10.0
Ω (approx)
FREQUENCY: (Auto, sensitivity selected by pressing RANGE Button)
Range
(Hz)
Resolution
(Hz)
Accuracy
Sensitivity
Overload
Protection
1-100K
0.001-100Hz
0.5% 2dgts
5V
AC 600V
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-
CAPACITANCE:
Range
Resolution
Accuracy
Overload Protection
40nF
10pF
5.0% 0.2nF
AC 600V
400nF
0.1nF
3.0% 0.2nF
AC 600V
4
μ
1nF
3.0% 0.02
μ
F
AC 600V
40
μ
F
10nF
3.0% 0.02
μ
F
AC 600V
400
μ
F
100nF
3.0% 0.02
μ
F
AC 600V
+-
+-
+-
+-
+-
+-
+-
+-
+-
+-