1
2
3
4
• TAP the Workshop Information Icon.
6
Reports are stored in Vehicle History, accessible through
Data Manager or through Diagnostics under the History
tab.
The generated Pre- and Post Scans are now complete
with shop information and ready to be emailed to
insurance company or printed for customer review.
PRE/POST SCAN REPORTS
• Select the Data Manager icon on the MaxiSYS
home screen.
Repair Shop: Stormy's Vehicle Repairs
Report Number: MAXIA20200616
Phone Number: 1631671549
Creation Date: 2020-06-16
Address: 123 Nathan Hale Drive
Repair order:
AAW67521
Client:
Client Phone Number:
VIN:
I2J6YH28543L01742
Mileage:
164674
Color:
2004 Honda Vehicle Diagnostic Report
Scan type:
Pre-scan&Post-scan
License Plate:
CYC3236
Manufacturer:
Honda
Year:
2004
Model:
Element
Sub Model:
USA
Engine:
Path:
Honda>Post-Scan>
IInnssuurraannccee iinnffoorrm
maattiioonn
Insured name:
B Smith
Claim number:
Contact Information:
City state zip:
Insurance company:
Alrighyinsurance Co
Address:
Primary impact:
PPrree--ssccaann R
Reeppoorrtt
2020-06-15 17:19:13
System
Status
1. Engine-PGM FI
Fault | 1
2. AT
Pass|No Fault
3. ABS/TCS/VSA
Fault | 1
4. SRS
Fault | 1
5. IMMOBI
Pass|No Fault
D
DTTC
C
1. Engine-PGM FI( 1 DTC )
DTC Code
DTC Description
Status
1.1 P0442
EVAP system small leak
Permanent DTC
2. ABS/TCS/VSA( 1 DTC )
DTC Code
DTC Description
Status
2.1 23-1
Right rear pulsar failure
Permanent DTC
3. SRS( 1 DTC )
DTC Code
DTC Description
Status
Prior to Running Pre/Post Scans, it is recommended the following steps are taken to customized the reports.
To Add logo: Tap the image icon and select from the
drop-down menu to either take a photo with the tablet
or to upload an image from the tablet.
Complete the fields on this screen by tapping on each
field and inputting information. The information entered
here will display on every Pre and Post Scan generated.
7
6
8
5
Access stored report
Select pencil icon and from drop-down menu, choose
view, print, or email report.
ONLY REGISTERED AUTEL TOOLS CAN DOWNLOAD SOFTWARE UPDATES
This quickstart guide applies to the MaxiSys
®
Ultra, MaxiSys
®
MS919 and MaxiSys
®
MS909.
QUICKSTART GUIDE