Содержание Dymanic Series

Страница 1: ...ing unit D 1 ENG DYNAMIC SERIES Part D ARM receiving unit INDEX 1 Description D 2 3 Technical data sheet D 3 4 Plates D 4 5 Light signals D 4 6 Values of proportional outputs D 7 7 Data memory backup D 10 8 Malfunction signalled by the receiving unit D 11 ...

Страница 2: ...it is a slave node The STOP STP_1 and STP_2 and SAFETY SAF_1 and SAF_2 outputs are some of the receiving unit s outputs A mounting holes G fuse F1 B antenna H fuse F2 C LEDs L fuse F3 D TEACH pushbutton M fuse F4 E connector for cable control N fuse F5 F plug P DTK connector for data memory Q IDK for address key R BKK connector for backup data memory A B F A C E E D G H L M N P Q R Mother board ...

Страница 3: ...ofuse Protection SAF_1 fuse F5 7 5 A 32 V autofuse Housing material PA6 20 fg Protection degree IP65 NEMA 4 Dimensions 200 x 230 x 95 mm 7 9 x 9 1 x 3 8 In Weight 3 kg 6 6 Lb 3 Technical data sheet The technical data sheet contains the wiring diagram showing the connection be tween the receiving unit and the machine It also contains the transmitting unit configuration and shows the matching be twe...

Страница 4: ...eceiving unit and of the radio link 2 ALARM LED red Plate Position Content radio remote control identification plate On the cover of the receiving unit Radio remote control serial number bar code S N and manufacturing year technical data plate On the cover of the receiving unit MODEL TYPE and main receiving unit technical data marking and possible radio remote control marks The POWER LED Meaning i...

Страница 5: ...303 3 The ALARM LED Meaning is off The receiving unit works correctly blinks once Error on the STOP outputs blinks twice Error on the SAFETY outputs blinks three times Error on the outputs corresponding to direction com mands is on The receiving unit does not work correctly The STATUS LED Meaning is off No radio link blinks slowly Over voltage on power supply blinks fast The receiving unit receive...

Страница 6: ...links twice Error on the data memory blinks slowly three times Calibration of the rest position values for proportional outputs see paragraph 6 2 or the procedure Copy data memory see chapter 7 is being performed blinks quickly three times The receiving unit is saving data set with the REMOTE SETUP procedure see chapter 6 blinks four times Inversion of movement direction of the joysticks axis is b...

Страница 7: ... proportional out puts 1 Start up the radio remote control 2 Press the TEACH pushbutton in the receiving unit and do not release it until the SETUP LED illuminates 3 Set the desired values as follows To set the maximum value move the joystick to the maximum range of the semi axis to be calibrated Maintain the position and use the TEACH selec tor on the transmitting unit to set the desired value To...

Страница 8: ...ed to the corresponding switch on the transmitting unit 4 Press and release the START pushbutton 5 Repeat actions described in points 3 and 4 until the SETUP LED on the re ceiving unit starts blinking three times 6 Set the desired values as follows Move the joystick out of the rest position of the axis to be calibrated Main tain the position and use the TEACH selector on the transmitting unit to s...

Страница 9: ...ibrations are saved in the data memory on the DTK connector To set other values unlock the STOP pushbutton press the START push button and repeat actions described in point 6 7 To leave the procedure press the TEACH pushbutton on the receiving unit and do not release it until the SETUP LED switches off 6 4 Restoring factory settings This procedure is used to restore factory settings for the propor...

Страница 10: ... memory of the BKK connector during the backup procedure Perform the following steps to copy the information of the data memory 1 Make sure that the transmitting unit and the receiving unit are not powered 2 Open the receiving unit 3 Make sure that a data memory is plugged in the DTK connector 4 Insert the memory attached inside the receiving unit cover in the BKK connector 5 Close the receiving u...

Страница 11: ...the connecting plug Make sure that the STOP outputs are wired correctly The ALARM LED blinks twice Error on the SAFETY outputs Make sure that fuses F1 and F5 are intact Correctly plug in the connecting plug Make sure that the SAFETY outputs are wired correctly The ALARM LED blinks three times Error on the outputs corresponding to direc tion commands Contact the support service of the machine manuf...

Страница 12: ...AN communication error Contact the support service of the machine manufacturer The SETUP LED blinks once Error on the address key Contact the support service of the machine manufacturer The SETUP LED blinks twice Error on the data mem ory Replace the data memory on the DTK connector with the backup data mem ory attached inside the cover see chapter 7 The SETUP LED blinks slowly A data memory is co...

Отзывы: