![Austro Engine AE50R Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/austro-engine/ae50r/ae50r_installation-operation-and-maintenance-manual_3019989044.webp)
AE50R, AE50RA
AE50RAB
Engine Manual
Doc. No. E1.01.0-E
Rev. 6 10-March-2011
Page 15-2
15.4 Ground Run Check List (example)
ENGINE GROUND RUND RESULTS
Date:………………..
A/C
Reg………………..
Engine
No………………..
Flight Hours………………..
Total Running Time (hrs meter)………………..
QFE………………..
Outside
Air
Temperature………………..
Instrumentation – Gauge / Alarm Function Test
Pressure Temperature
Others
RCAO
Battery Fail Alarm
Low Fuel Pressure Alarm
Engine Coolant
Charge System Fail Alarm
OAT
Flytronic Error Warning
EGT 1 (optional)
Fuel Flow
Oil Low Alarm
Record data after 1 minute steady running at each condition after warm – up
Engine
Coolant
RCAO
Remarks
RPM
Temp
Temp
Warm
–
up
……….
………… ……….
……………
Idle
……….
………… ……….
……………
5000
……….. ………… ……….
……………
6000
……….. ………… ……….
……………
Max
……….
………… ……….
……………
Idle
……….
………… ……….. ……………
Ign.
1
Ign.
2
Mag Drops at 6000 RPM
……….
……….
Acceleration
tests
(3
off) Remarks
(Idle to Max RPM response)
………………………………………………….
(1
sec
throttle
time)
………………………………………………….
Comments
If any adjustments are made as a result of this ground run they
should be recorded and the ground run repeated
…………………………………………………………………………………………………………….
…………………………………………………………………………………………………………….
…………………………………………………………………………………………………………….
Record results in engine maintenance file !