![Austro Engine AE50R Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/austro-engine/ae50r/ae50r_installation-operation-and-maintenance-manual_3019989034.webp)
AE50R, AE50RA
AE50RAB
Engine Manual
Doc. No. E1.01.01-E
Rev. 6 10-March-2011
Page 12-2
12.2 Typical 50 Hours Check
NOTE !
Visual Checks Only unless stated! All Checks to include Fastenings, Cracking,
Leaks, Discoloration and Wire Locking!
WARNING !
Ensure that all switches are OFF before rotating the engine.
11
Starter Ring – rotate Engine via Prop
Chipped or missing teeth
12
Generator Cables
Signs of contact and chafing/cracking
13
Lower Timing Sensor and Cables
Signs of contact and chafing/cracking
14
Water Pump Housing
Vent hole
15
Upper Timing Sensor and cables
Signs of contact and chafing/cracking
16 Fan
Housing
Cracks
17
Fan Belt
Check tension and condition
18
Fan Filter – remove and check
View fan impeller – Debris – Cracks
19
Engine Mounts – port side
Nuts, bolts
20
Fuel Rail, Injector, Pressure Regulator
Leaks – Cracks – Cable Connection
21
Linkage, Throttle Stops
22
Ram Pipe
Check temperature sensor connection
23
Induction Air Filter
Cleanliness and damage
24
Rotor Housing drain screw
Security – leaks
25
Exhaust System - complete
Overheat adjacent parts – security
26
Voltage Regulator and Cables
Signs of deterioration
27
CDI and Trigger Cables
Signs of deterioration
REF
ITEM
CHECKS / COMMENTS
1
Water Outlet Cover
Leakage
2 Water
Hoses
Security
of all clips – leaks
3
Oil Separator
Leakage and temperature sensor connection
4
Oil Pump – Lines and
Terminations
Leakage
5
Spark Plug Coils and Plug Caps
Cables and terminations
6
Spark Plug Condition
Connection & gap area
7
Engine Mounts – Starboard Side
Nuts, bolts secure
8
Starter Motor Mounts and Cable
Bolts and cable connections
9
Starter Pinion – Condition and
Laxity
Teeth, free movement, play
10
Generator (Stator / Rotor)
Note any debris in the area