www.austriamicrosystems.com
Revision 1.10
76 - 86
AS3542 3v2
Data Sheet, Strictly Confidential - R e g i s t e r D e f i n i t i o n
Table 80. Thrid Interrupt Register
Name
Base
Default
IRQENRD_2
2-wire serial
00h
Offset: 25h
Third Interrupt Register
Please be aware that writing to this register will enable/disable the
corresponding interrupts, while with reading you get the actual interrupt
status and will clear the register at the same time. It is not possible to read
back the interrupt enable/disable settings. This register is reset at a AVDD27-
POR.
Bit
Bit Name
Default
Access
Bit Description
7
BATTEMP_IRQ
0
W
Battery over-temperature interrupt setting.
0: disable
1: enable interrupt if battery temperature exceeds 45/55°C
The interrupt must not be enabled if the charger block and
battery temperature supervision is disabled
x
R
Battery over-temperature interrupt reading
0: battery temperature below 45/55°C
1: battery temperature was too high and the charger was
turned off. The charger will be turned on again, when the
temperature gets below 42/50°C
6
CHG_EOC
x
R
Battery end of charge interrupt reading
0: battery charging in progress
1: charging is complete, charging current is below 10% of
nominal current, turn off charger
5
CHG_CON
x
R
0: no charger input source connected
1: charger input source connected, also valid if charger is
connected during wakeup
4
CHG_IRQ
0
W
Charger status change interrupt setting
0: disable
1: enables an interrupt on a low to high or high to low change
of CHGIN pin or on an EOC condition
CHG_changed
(status change)
x
R
Charger input status change interrupt reading
0: charger status not changed
1: charger status changed, check CHG_CON, CHG_EOC
3
USB_CON
0
n/a
0: no USB input connected
1: USB input connected, also valid if USB is connected during
wakeup. The threshold can be set in the USB_UTIL register
(1Ah)
2
USB_IRQ
0
W
USB input status change interrupt setting
0: disable
1: enables an interrupt on a low to high or high to low change
of VBUS pin. The threshold can be set in the USB_UTIL
register (1Ah)
USB_changed
(status change)
x
R
USB input status change interrupt reading
0: USB input status not changed
1: USB input status changed, check USB_CON