ZMPS
INSTALLATION AND OPERATION MANUAL
5
Daisy chain wiring from ZONEMIX to multiple pagers
CONNECTING THE ZMPS
Pin
Colour
Signal
1
Green/White
Paging Audio +
2
Green
Paging Audio -
3
Orange/White
RS485 B
4
Blue
+24V DC
5
Blue/White
GND
6
Orange
RS485 A
7
Brown/White
Local Input +
8
Brown
Local Input -
ZONEMIX
ZMPS WIRING
DAISY CHAINING ZMPS STATIONS
Wire the ZMPS paging station as per the images below.
Category 5, 5e and 6 cabling are supported.
T-568A wiring is recommended. However, T-568B is also supported.
1
2
Termination DIP switches
ZMPS TERMINATION (DO NOT SKIP THIS STEP)
If the ZMPS is the LAST device on an accessory port cable run it MUST
be terminated using the rear panel "PORT TERM" DIP switches by turning
them to the ON position.
If the ZMPS is NOT the LAST device on the accessory port cable run the
"PORT TERM" switches must be OFF.
The ZONEMIX system uses the RS485 standard to communicate with
the paging stations. RS485 requires that each end of a cable run is
terminated to prevent signal corruption due to signal reflections in the
cable.
3
T-568A wiring (Tab down view)
If you need to daisy chain ZMPS paging stations on the same accessory
port run, use a terminal block or RJ45 splitter as shown. (Not included)
GREEN/WHITE
GREEN
ORANGE/WHITE
BLUE
BLUE/WHITE
ORANGE
BROWN/WHITE
BROWN
1
2
3
4
5
6
7
8