Revision 1.0: June 2022

INTRODUCTION & CONTENTS

Introduction

3

Controls

4

Connecting the ZMPS

5

Specifications

7

ZMPS Drawings

8

 

Rating plate and caution marking are marked on the back enclosure of the apparatus

WARNING

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH AN EXTENSION CORD, RECEPTACLE 

OR OTHER OUTLET UNLESS THE BLADES  CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE 

TO RAIN OR MOISTURE.

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT 

CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.

The lightning flash with 

arrowhead symbol, within 

an equilateral triangle, is 

intended to alert the user to 

the presence of uninsulated 

“dangerous voltage” within the 

product’s enclosure that may 

be of sufficient magnitude to 

constitute a risk of electric 

shock to persons.

WARNING

TO REDUCE THE RISK OF 

ELECTRIC SHOCK, DO NOT 

REMOVE COVER (OR BACK).

NO USER SERVICEABLE PARTS 

INSIDE. REFER SERVICING 

TO QUALIFIED SERVICE 

PERSONNEL.

The exclamation point  

within an equilateral triangle 

is intended to alert the user 

to the presence of important 

operating and maintenance 

(servicing) instructions in  

the literature accompanying 

the appliance.

For European Union countries: This symbol on  

the product or its packaging indicates that this 

product must not be disposed of with other waste.

Instead, it is your responsibility to dispose of your 

waste equipment by handing it over to a designated 

collection point for the recycling of waste  

electrical and electronic equipment.

Please contact your local authority for further details 

of your nearest designated collection point.

The Australian Monitor ZONEMIX Paging Station 
(ZMPS) is a software configurable paging station with 
a supercardioid gooseneck microphone.

The ZMPS is designed to be used with the ZONEMIX 
system to provide paging and pre-recorded message 
playback to individual zones, combination of zones or all zones. 
Connection to the ZONEMIX is via low cost CAT 5 cable.

Ample label space is provided on the ZMPS for easy operation 
and LED indicators provide the user with visual feedback of 
the zones being paged or if the system is busy.

A rear panel gain control allows level adjustment along 
with an internal audio limiter to guarantee voice 
clarity.

Содержание ZMPS

Страница 1: ...INSTALLATION AND OPERATION MANUAL ZMPS ZONING PAGER ...

Страница 2: ...1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs regi...

Страница 3: ... SERVICING TO QUALIFIED SERVICE PERSONNEL The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instead it...

Страница 4: ...oups of zones or to activate a pre recorded announcement Use the ZONEMIX PC control software to assign the required function to each button SOFTWARE DEFINED BUTTON 5 The chime LED will turn on to indicate the pre announce chime is playing Do not speak through the ZMPS until this LED is off CHIME 6 The busy LED will turn on when the system is busy performing another page This can be caused by the l...

Страница 5: ... NOT SKIP THIS STEP If the ZMPS is the LAST device on an accessory port cable run it MUST be terminated using the rear panel PORT TERM DIP switches by turning them to the ON position If the ZMPS is NOT the LAST device on the accessory port cable run the PORT TERM switches must be OFF The ZONEMIX system uses the RS485 standard to communicate with the paging stations RS485 requires that each end of ...

Страница 6: ...he ZMPS is waiting to be PAIRED with the ZONEMIX using the PC control software 4 PAIRING AND CONFIGURATION Pairing and configuring the ZMPS is performed using the ZONEMIX control software available on the Australian monitor website www australianmonitor com au Please consult the ZONEMIX4 8 manual for detailed instructions on pairing ZMPS stations and configuring the button functions 5 CONNECTING T...

Страница 7: ... Green LED on programmable buttons and Chime Red LED on Busy CONNECTION RJ45 FOR POWER AUDIO AND COMMS Supports UTP Cat5 Cat5e and Cat6 POWER DC INPUT Via RJ45 24V DC 45mA MISCELLANEOUS PRODUCT DIMENSIONS 132mm x 173 9mm x 350mm 5 2 W x 6 9 D x 13 8 H SHIPPING DIMENSIONS 350mm x 200mm x 145mm x 13 8 W x 7 9 D x 5 7 H NET WEIGHT 1 0kg SHIPPING WEIGHT 1 5kg OPERATING TEMPERATURE 0 C to 40 C FINISH P...

Страница 8: ... 1 2 Daydream Street Warriewood NSW 2102 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ABN 86 003 231 187 ZMPS DRAWINGS 350 0 mm Mid Position 132 0 mm 40 0 mm 132 0 mm 173 9 mm ...

Отзывы: