CLASS 2 WIRING
Audio Amplifier
Model: AMC+120P
Rated Value:
115V~60Hz 460W
230V~ 50Hz 460W
Manufacture Date:
Made In China
CERTIFIED TO
CAN/CSA STD.C22.2
No.60065
CONFORMS TO
ANSI/UL SYD.60065
230 V. FUSE T2AH 250V
115 V. FUSE T4AH 250V
1
3
2
4
5
1
Input
These 3 pin XLR sockets accept the source input for each
channel. One input is a male XLR, the other is a female
XLR. The male XLR is normally used as a thru output. When
wiring from unbalanced sources, pins 1 and 3 should be
shorted together (see Installation section). The input sensitivity
(voltage required to drive amplifier to maximum power) of the
amplifier is 150mV (-14dBu) with the Input Level Control set
at maximum.
2
Level
This pot controls the level of the signal through the amplifier
channel. Minimum position is Off and maximum gives a
sensitivity of 150mV (-14dBu). The maximum input voltage
before the input stage clips is 2.45V (+10.0dBu). Depending
on the input source, the input level control should be run
above the 12 o’clock position (half way) to avoid clipping the
input stage.
3
Direct Out
Speaker connections are provided on screw terminals.
4 ohm low impedance, 70V and 100V line outputs are
provided.
Direct Out continued
Minimum Impedance
AMC
+
120P AMC
+
250P
Distributed Line Output
70V
41ohm
20ohm
100V
83ohm
40ohm
Low Impedance Output
(both versions)
4ohm
4ohm
NOTE:
Only connect one output – either Distributed Line or Low Impedance per channel.
Do not connect LowZ and 70/100V at the same time.
The output strip comes fitted with a touch-proof cover held in place by two M3 machine screws
with flat and spring washers.
4
IEC Mains Input Socket
This is a standard IEC 3 pin socket. It accepts a standard IEC mains cable, provided. The fuse
draw at 5 contains the mains fuse and a spare. The mains fuse is a time lag (slow blow)
HRC 20mm x 5mm ceramic type fuse.
Ratings
AMC+120P AMC+250P
230V operation
2A
4A
115V operation
4A
8A
Always replace the fuse with one of the same value and type.
Always disconnect power to the amplifier before replacing fuses.
5
Mains Voltage Selector
The operating voltage of the amplifier is user selectable between for 115V or 230V operation
via a slide switch located above the AC mains inlet. This switch should be set to match the AC
voltage of your country.
Failure to set the Mains Voltage Selector correctly prior to use will
result in catastrophic failure.
This terminal is hazardous live and that external wiring connected
to these terminals requires installation by an instructed person.
PAGE 5
AMC
+
SERIES INSTALLATION AND OPERATION MANUAL
REAR PANEL
Содержание AMC+120P
Страница 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIERS AMC 120P AMC 250P AMC SERIES ...
Страница 9: ...PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL BLOCK DIAGRAM ...
Страница 12: ...PAGE 12 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...
Страница 13: ...PAGE 13 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...