AUSTRALIAN MONITOR AMC+120P Скачать руководство пользователя страница 3

AMC+ SERIES 

The Australian Monitor Installation Series AMC+ range of booster 
amplifiers take the rugged reliability of the famous AMIS range and 
deliver the same high quality audio reinforcement, in a low cost,  
2 rack unit package. The AMC+ booster amplifiers are available in 
120 & 250 watts & offer 100 volt or 4 ohm outputs. 

The AMC+ series booster amplifiers give the audio contractor 
a reliable, low cost booster amplifier for applications that are 
price sensitive but still require high quality commercial sound 
reinforcement.  

Revision 1.3 October 2011

INTRODUCTION 3

FRONT PANEL 

4

REAR PANEL 

5

INSTALLATION 6

TROUBLESHOOTING AND BLOCK DIAGRAM 

7

DIMENSIONS 8

SPECIFICATIONS 9

NOTES 10

WARNING!

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH  

AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES  

CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE 

THIS APPLIANCE TO RAIN OR MOISTURE. 

TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT & FULLY INSERT.

CAUTION

THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY.  

TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT 

CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

The lightning flash with arrowhead symbol, 

within an equilateral triangle, is intended  

to alert the user to the presence of 

uninsulated “dangerous voltage” within  

the product’s enclosure that may be of 

sufficient magnitude to constitute a risk  

of electric shock to persons.

WARNING:

 TO REDUCE THE RISK  

OF ELECTRIC SHOCK, DO NOT  

REMOVE COVER (OR BACK). 

NO USER SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED  

SERVICE PERSONNEL.

The exclamation point within an equilateral 

triangle is intended to alert the user to 

the presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

Rating plate and caution marking are marked on the back enclosure of the apparatus

PAGE 3

AMC

+

 SERIES INSTALLATION AND OPERATION MANUAL

INTRODUCTION AND CONTENTS

Содержание AMC+120P

Страница 1: ...INSTALLATION AND OPERATION MANUAL POWER AMPLIFIERS AMC 120P AMC 250P AMC SERIES ...

Страница 2: ... les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs registres de chaleur fours ou les autres équipements y compris amplificateurs qui produisent la chale...

Страница 3: ...TO PREVENT ELECTRICAL SHOCK MATCH WIDE BLADE PLUG TO WIDE SLOT FULLY INSERT CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbo...

Страница 4: ... or off the mains The up position is on 3 Vents Air intake for fan cooling on AMC 250P only To indicate hazards arising from dangerous voltages Pour indiquer les risques résultant de tensions dangereuses Hot surface Don t touch here PAGE 4 AMC SERIES INSTALLATION AND OPERATION MANUAL FRONT PANELS ...

Страница 5: ...t continued Minimum Impedance AMC 120P AMC 250P Distributed Line Output 70V 41ohm 20ohm 100V 83ohm 40ohm Low Impedance Output both versions 4ohm 4ohm NOTE Only connect one output either Distributed Line or Low Impedance per channel Do not connect LowZ and 70 100V at the same time The output strip comes fitted with a touch proof cover held in place by two M3 machine screws with flat and spring wash...

Страница 6: ...o suit the nuts threads in the rack Montage Cet ampli convient pour un montage en rack de 19 et a 2 unités de 3 5 Les centres de montage sont Vertical 3 0 soit 76 2 mm Horizontal de 18 2 soit 461 2mm à 18 7 soit 473 8 mm Vous pouvez mettre des vis de 6 5 mm maximum dans ls fentes de la bride de montage Nous vous recommandons un support supplémentaire car le poids peut parfois faire plier le chassi...

Страница 7: ...shielded pair cable is recommended NOTE When wiring the LINE output as unbalanced Pin2 should be wired as hot and Pin1 should be wired as ground shield Do not wire Pin3 REC Output The REC output wiring should be kept as short as possible Input Connections For wiring balanced in pin 2 is hot Unbalanced wiring on the microphone inputs is not recommended Balanced input wiring shielded pair cable is r...

Страница 8: ... turned up Check speaker loads for shorts Reduce input level at source Reduce volume levels on front panel Reduce Bass control level No sound but amp is on Volume controls down Amplifier has overheated AMC 60 AMC 120 AMC 250 only DC fuse s blown Check volume controls Check for obstructions above and below Make sure the amplifier is well ventilated Refer product to local Australian Monitor dealer P...

Страница 9: ...PAGE 9 AMC SERIES INSTALLATION AND OPERATION MANUAL BLOCK DIAGRAM ...

Страница 10: ...dio Amplifier Model AMC 120P Rated Value 115V 60Hz 460W 230V 50Hz 460W Manufacture Date Made In China CERTIFIED TO CAN CSA STD C22 2 No 60065 CONFORMS TO ANSI UL SYD 60065 230 V FUSE T2AH 250V 115 V FUSE T4AH 250V PAGE 10 AMC SERIES INSTALLATION AND OPERATION MANUAL DIMENSIONS ...

Страница 11: ... 27 6lb 30 8lb SHIPPING DIMENSIONS WxHxD 525 x 175 x 385mm 525 x 185 x 470mm 20 7 x 6 9 x 15 2 20 7 x 7 3 x 18 5 MAINS CURRENT DRAW 230V FULL POWER 1 20A 2 53A 1 3 POWER 0 80A 1 61A 1 8 POWER 0 55A 1 10 IDLE 0 15A 0 15A MAINS CURRENT DRAW 115V FULL POWER 2 50A 5 28A 1 3 POWER 1 67A 3 36A 1 8 POWER 1 15A 2 30A IDLE 0 31A 0 31A THERMAL OUTPUT W FULL POWER 128W 259W 1 3 POWER 118W 231W 1 8 POWER 91W ...

Страница 12: ...PAGE 12 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...

Страница 13: ...PAGE 13 AMC SERIES INSTALLATION AND OPERATION MANUAL NOTES ...

Страница 14: ...iries email international australianmonitor com au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www hillssvl com au NSW QLD ACT WA VIC SA NZ P 02 9647 1411 P 07 3852 1312 P 02 6260 4544 P 08 9204 0200 P 03 9890 7477 P 08 8408 8300 P 09 415 9426 E nsw hillssvl com au E qld hillssvl com au E act hillssvl com au E wa hillssvl com au E vic hillssvl com au E sa hillssvl com au E sales hillssvl...

Отзывы: