background image

6

AL

C UIM Mega E

yebol
t_

21

Australian Lifting Centre

USER INS

TRUC

TION MANU

AL

ME

GA E

YEBOL

T

7.  Make sure both joint area are clean, eyebolts cannot work on partially 

joined surface.

8.  Fit the eyebolt on the lifting object, ensure that the ring is leaning in the 

same direction as the lifting slings.

A competent person must supervise and guide the lifting process, pay 

attention to the center of gravity and the position of the product to make 

sure that all eyebolts on the job are within the working load limit.

Major factors affecting lifting capacity:

•  Do not use the product in acidic or highly corrosive chemical 

environment or explosive environment.

•  Do not use the product at temperatures above 350 °C or below minus 

20 °C.

•  The product is intended for use by people who have received proper 

training and are competent.

•  Do not modify the eyebolt with any other grade, quality or size bolt; 

otherwise, it will compromise this product's integrity.

•  Do not replace the bolt and or modify the original fittings.
•  Do not stand under hanging load to work with the product.
•  During use, do not stand in hazardous areas. (Hazardous areas are those 

areas that are exposed to or under the moving load.)

•  Do not make any alterations or do welding to the product without the 

manufacturer’s prior written consent.

•  Repair is permitted, provided that it is either done by Austlift or a 

competent Austlift dealer.

TEMPERATURE

(°C)

WORKING LOAD 

REDUCTION 

FACTOR

-20 ~ 200

None

200 ~ 30

10%

300 ~ 350

25%

Above 350

Do not use

Storage:

 When not in use, store the product in appropriate environment. 

(dry, non-corrosive)

We declare that all materials involved in this instruction manual are 

manufactured in compliance with machinery directive 2006/42/EC 

and the swivel is manufactured to AS2318 at proper testing procedure.

DECLARATION

Содержание 605208 Series

Страница 1: ... EYEBOLT 605208 605248 series Mega Eyebolt with short thread 605508 605548 series Mega Eyebolt with long thread Lifting Your Business to A Higher Level 1300 100 120 www austlift com au AUSTRALIAN LIFTING CENTRE PTY LTD ...

Страница 2: ...WARNING A L L1 180º ø C D SIZE mm SHORT THREAD LONG THREAD WLL T BL T DIMENSIONS mm CODE Wt kg THREAD LENGTH L1 mm CODE Wt kg THREAD LENGTH L1 mm Ø A C D E M L M8 605208 0 36 10 4 605508 0 39 76 0 3 1 2 14 30 35 55 52 5 8 35 6 M10 605210 0 38 16 605510 0 43 96 0 63 2 52 14 30 35 55 52 5 10 36 M12 605212 0 71 18 605512 0 8 114 1 4 18 36 40 68 54 12 44 M14 605214 0 72 21 605514 0 86 140 1 22 4 8 18 ...

Страница 3: ... 1 26 1 26 0 88 0 63 1 32 0 95 0 63 M12 1 0 1 0 2 0 2 0 1 4 1 0 2 1 1 5 1 0 M14 1 2 1 2 2 4 2 4 1 68 1 2 2 52 1 8 1 2 M16 1 5 1 5 3 0 3 0 2 1 1 5 3 15 2 25 1 5 M18 2 0 2 0 4 0 4 0 2 8 2 0 4 2 3 0 2 0 M20 2 5 2 5 5 0 5 0 3 5 2 5 5 25 3 75 2 5 M24 4 0 4 0 8 0 8 0 5 6 4 0 8 4 6 0 4 0 M27 4 0 4 0 8 0 8 0 5 6 4 0 8 4 6 0 4 0 M30 5 0 5 0 10 0 10 0 7 0 5 0 10 5 7 5 5 0 WORKING LOAD LIMIT CHART FEATURES H...

Страница 4: ...er As you can see on the product Mxx Metric diameter e g M16 12 9 The class of the bolt is 12 9 This means the bolt can take 120kg per sq mm and it will start failing at 90 of that load This is the highest tensile in metric bolts equivalents around G90 USER INSTRUCTIONS Ring working angle range You can adjust the eyebolts lifting angle by positioning the eyebolt as per the diagrams below do not ex...

Страница 5: ...ver the standard tractive resistance of steel in EN 10025 S235JR 5 The thread must be perpendicular to the surface of the object being lifted 6 Eyebolt should be tightened with a torque wrench as to the below chart SIZE M8 M10 M12 M14 M16 M20 M24 M27 M30 Tightening torque Nm 25 30 55 60 95 100 110 120 140 150 390 400 750 760 750 760 750 760 USER INSTRUCTIONS Inspection on eyebolts All liftings eye...

Страница 6: ...raining and are competent Do not modify the eyebolt with any other grade quality or size bolt otherwise it will compromise this product s integrity Do not replace the bolt and or modify the original fittings Do not stand under hanging load to work with the product During use do not stand in hazardous areas Hazardous areas are those areas that are exposed to or under the moving load Do not make any...

Страница 7: ......

Страница 8: ...ut notice 1300 100 120 AUSTRALIAN LIFTING CENTRE www austlift com au Head Office NSW 43 Frank Street Wetherill Park NSW 2164 Ph 02 9757 2277 WA Office 42 Mulgul Road Malaga WA 6090 Ph 08 9248 6674 VIC Office 475 Dohertys Road Truganina VIC 3029 Ph 03 9314 5525 QLD Office 7 Durbell Street Acacia Ridge QLD 4110 Ph 07 3272 0777 ALC UIM Swivel Large Eyebolt_21 ...

Отзывы: