Installation Notes

•  Read all precautions, installation and operating 

instructions carefully and completely before 
installing the unit.

•  Ensure all contents are present prior to 

installing.

•  Lay out system in appropriate configuration.  

Improper sequence of equipment will affect 
performance, and could possibly damage your 
system.

•  For systems with pro-grade installation kits, 

anticipate the addition of pex tubing, clamps 
and mounting screws to install unit properly 
(available at your local home improvement 
store or through your plumbing contractor). 
Due to the varieties of home design, not all 
configurations can be addressed in this guide.  
Components and time of installation will vary. 
Please refer your plumbing professional to our 
Installation Guide.

•  Do not install this filter where the line pressure 

may exceed 100 psi. Operating pressure range: 
20psi – 100psi.

•  Select an appropriate installation location.  

Dimensions of systems vary—always allow an 
estimated minimum of 50” clearance for height 
of tank, and a minimum of 30” for floor space. 
Your plumber will be installing the system in 
an area where the main water line enters your 
home, prior to your water heater.

•  Do not install the unit on its side. It needs to 

be installed upright to maximize contact with 
media. It is recommended your system be 
installed inside and out of direct sunlight. If this 
is not possible and the system is outdoors or 
in a sunny area, the installation requires the 
use of sun-proof sumps.  Please contact our 
sales and service department 866-238-5855 to 
discuss the specifics of your installation.

•  Full warranty contingent on installation by a 

licensed plumber.

•  Install on cold water lines only (40° – 90°F). 

Protect unit from freezing.

•  Installation of the filter must comply with 

existing state and local plumbing codes. 
Austin Springs is not liable for consequential 
or incidental damages due to  improper 
installation. 

Do not use with water that is microbiologically unsafe or of 

unknown water quality without adequate disinfection before or 

after the system. Systems certified for cyst reduction may be used 

on disinfected water that may contain filterable cysts.

Installation

1. KEEP UPRIGHT AT ALL TIMES.

2. Remove the red shipping caps from the inlet & 

outlet ports on the main housing. 

3. Precondition the unit by flushing:

   

It is very important that this system is flushed 
properly prior to final installation. Using the 
supplied adapter, connect a garden hose to 
the inlet port so that the water will flow into 
the system and out of the outlet port. Slowly 
turn on the water and allow the cloudy water 
to flow from the outlet into a bucket 
or drain. Flush the NAC tanks for 
5-10 minutes. Once the unit 
has been properly flushed, 
be sure the white washers 
are properly set inside 
the inlet and outlet ports. 
Disconnect it from the garden 
hose and position it for final 
installation

4. Turn off main source water 

supply prior to installation. 

5.  Install the unit to the main water supply 

using the supplied components. Do not over 
tighten fittings, as this may cause leakage 
and broken fittings. Do NOT use pipe dope. 
The use of pipe dope voids the warranty. You 
may use NSF Certified pipe primer, glue and 
plumber’s tape. Leave two-three threads 
exposed and do not exceed seven layers of 
plumber’s tape. More than seven layers will 
cause the nipple to crack and leak.

6. IMPORTANT:

  

The inlet piping assembly (valve, 

pre-filter, main filter unit, union 

and nipples) must be firmly 

braced and supported.

7. Once installation is complete, 

slowly turn the water on and 

inspect for leaks.

8. Once the unit is installed and 

checked for leaks, open the water 

faucet closest to the installed 

unit and allow water to run for 
10 minutes for the final flushing 
period.

9. This unit must be installed 

by a licensed plumber to 

validate the warranty.

Flush

for

10

  

min.

Flush

for

10

  

min.

Specifications

Model: 

AS-WH-AST

Replacement cartridges 
 

Main tanks: 

AS-WH-AST-R

 

Pre-filter: 

AS-WH-PRE-4-R

Содержание AS-WH-AST

Страница 1: ...Installation Instructions AS WH AST Whole House Descaler ...

Страница 2: ...oticeably decreased it is time to replace the filter with a new one Allowing sediment to continue to collect can cause clogging and restrict the flow of water into your home AS WH AST Main Tank Replace the main tanks every 6 years You may consider adding a meter to your system at the time of installation Unions are located on each side of the tank for ease of replacement It is not necessary to con...

Страница 3: ... due to improper installation Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Installation 1 KEEP UPRIGHT AT ALL TIMES 2 Remove the red shipping caps from the inlet outlet ports on the main housing 3 Prec...

Страница 4: ...sed from for a Return Authorization Code and a full refund will be promptly issued upon return This system is designed and tested for use with genuine Austin Springs parts including replacement filters and all hardware Use of parts from other manufacturers may result in loss of contaminant reduction performance system damage or failure Use of parts from other manufacturers will also void your warr...

Страница 5: ...Austin Springs 1609 Shoal Creek 200 Austin Texas 78701 866 238 5855 AustinSprings com AS WH AST_20170413 ...

Отзывы: