MESSAGE
LOGGER
2
TROUBLESHOOTING
LOGGER 2 TROUBLESHOOTING | PROGRAMMING
23
BATTERY LOW
Return Logger to manufacturer
for analysis and repair.
Restart Logger, if problem continues, don’t use Logger.
Report problem.
INTERPRETATION
SOLUTION
Recharge batteries soon.
This message should start appearing when the battery is be-
low approximately 20% of capacity. Two hours of charging
will charge Logger to 80% of battery capacity.
DELAY AND DET# MUST NOT
BE 0
LOGGER FAILED SELF TEST
A zero value has been entered for either the delay time or the
detonator number. Zero is not permitted. Type in value from
range 1 to 20,000.
Detonator numbers must be
between 1 and 1,600.
Type in value from range 1 to 1,600.
DET # MUST BE 1 TO 1600
Delays less than 1 and greater
than 20,000 ms (in 1 millisecond
increments) cannot be entered.
Type in value from range 1 to 20,000 ms.
DELAY MUST BE 1 TO 20000
Factory preset delay is 712 ms
or 901 ms, any different delay
will show warning.
There is no defect with the detonator. Mark detonator s/n
and continue in programming.
WRONG DEFAULT DELAY