I.S. INTERCOM 

6 OF 6 

20-320-12 

TYPE ABMA3-1 USER MANUAL 

 

Issue: 03 

 

 

Figure 1: Simplified Un-Shielded Circuit 

 
If the shield is passed through from one cable to another between ABMA3-1 terminations and is not 
terminated at the R-Line then this is electrically noisier than having no shield at all. The coupling between 
shield and the V and S cores has the effect of giving alternative PSA signal paths that can cause the PSA 
Controller and ABMA3s to receive false confirmations on tail end units. 

 

4. CERTIFICATION 

The intercom type ABMA3-1 has been certified for use as part of the Pre-Start Alarm and Communication 
System type PSACS1. The ABMA3-1 may be used within any PSACS1 system in accordance with the rules 
set forth in certificate AUS Ex 02.3829X and Austdac system certification drawing 20-035-19. 
 
 
 
 
 
 
 
 

 

Содержание ABMA3-1

Страница 1: ...Title I S INTERCOM TYPE ABMA3 1 USER MANUAL Document Number 20 320 12 Issue 03 ...

Страница 2: ...s the property of Austdac Pty Ltd It is subject to its recall and must not be reproduced in part or whole or its contents divulged to third parties without prior written approval from Austdac Pty Ltd TABLE OF CONTENTS TABLE OF CONTENTS 2 PHOTOGRAPHS 2 FIGURES 2 1 GENERAL DESCRIPTION 3 2 OPERATIONAL DESCRIPTION 5 Pre start Alarm PSA 5 Detection of Speech for Speaker Mute Control 5 SPEAK key 5 CALL ...

Страница 3: ...ovide the voice communications interface for staff working along the conveyor belt A conversation with another worker along the conveyor belt can be initiated by pressing the call local button once or several times The call local button is used to signal or attract the attention of workers along the conveyor The call local button can be pressed and released to sound a series of beeps along the con...

Страница 4: ...xpose the battery charge current select jumper In the LO position the battery charge current is 11mA and 22mA in the HI position Refer to the system drawing for the correct charge rate for your intercoms Generally the HI position is used in systems with short powered segments and fewer intercoms the LO position is used in long powered segments with more intercoms Photograph 3 Battery type 5 NH 1 N...

Страница 5: ...at a DC voltage level between the system supply voltage and the supply voltage minus one volt If the DC voltage level on the V line with respect to the R line is changed to a value greater than six volts the pre start alarm controller will issue a CALL EXCHANGE tone 194Hz for about 4 seconds This CALL EXCHANGE tone is transmitted to all intercoms and the surface exchange pair This tone triggers a ...

Страница 6: ...upling between shield and the V and S cores has the effect of giving alternative PSA signal paths that can cause the PSA Controller and ABMA3s to receive false confirmations on tail end units 4 CERTIFICATION The intercom type ABMA3 1 has been certified for use as part of the Pre Start Alarm and Communication System type PSACS1 The ABMA3 1 may be used within any PSACS1 system in accordance with the...

Отзывы: