I.S. INTERCOM 

5 OF 6 

20-320-12 

TYPE ABMA3-1 USER MANUAL 

 

Issue: 03 

 

 
 

2. OPERATIONAL DESCRIPTION 

Pre-start Alarm (PSA) 

The unit continuously detects for a PSA paired tone signal on the V-line and broadcasts it through the 
speaker.   
 

Detection of Speech for Speaker Mute Control 

On detection of speech from another unit, due to someone having pressed the SPEAK key and is speaking 
above the mute level or squelch levels, the speakers are turned on.  

 

SPEAK key 

Pressing of the SPEAK key (a press to talk, ‘PTT’ action) the ABMA3-1 will turn off speakers and turn on the 
microphone. The unit will return to normal mode as soon as Speak key is release. 
 

CALL LOCAL key 

Pressing the CALL LOCAL key will cause the S Line to be pulled down signalling the PSA Controller to send 
out a tone indicating attention. The S line normally sits at a DC voltage level between the system supply 
voltage and the supply voltage less one volt. If the DC voltage level on the S line with respect to the R line is 
changed to a value greater than six volts, the pre-start alarm controller will issue a local call tone (1200Hz) 
for as long as the local call button is pressed. A CALL LOCAL tone can be requested from any intercom or 
BMA along the length of the conveyor. The CALL LOCAL tone is used to attract attention of personnel along 
the conveyor. 
 

CALL EXCHANGE key 

Pressing the CALL EXCHANGE key will request a CALL EXCHANGE tone from the controller, by changing 
the DC level of the V line. The V line normally sits at a DC voltage level between the system supply voltage 
and the supply voltage minus one volt. If the DC voltage level on the V line with respect to the R line is 
changed to a value greater than six volts, the pre-start alarm controller will issue a CALL EXCHANGE tone 
(194Hz) for about 4 seconds. This CALL EXCHANGE tone is transmitted to all intercoms and the surface 
exchange pair. This tone triggers a tone detector in the surface exchange that in turn rings an alarm to 
attract the exchange operator’s attention. 
 

3. INSTALLATION AND CONNECTIONS 

 

Cable Shielding 

From “PRE-START ALARM AND COMMUNICATIONS SYSTEM TYPE PSACS1” user manual (20-079-12) 
the following system cables are used: G2000 and G2000B both have a foil and drain wire and cable CABL25 
has no shielding at all. The cable is a very important part in the system as it carries all the signals and 
distributes power to all the system components. Of the conductors, two are larger in cross sectional area 
than the other two. The two larger cross sectional area conductors are used to distribute power to the system 
components while the smaller conductors are used to convey signals between the various system 
components. The smaller conductors are the ones that have a foil sheath in the G2000 and G2000B cables. 
The connection of foil sheath and drain wire is critical for correct installation. You must either use the shield 
cable correctly with the ABMA3-1 R-Line (Common line) terminated with a shield drain wire at each ABMA3-
1 or not use a shield foil/drain wire at all, which is the Austdac default method. The shield is not passed 
through and is left floating as depicted in the electrically simplified figure 1 over: 
 

Содержание ABMA3-1

Страница 1: ...Title I S INTERCOM TYPE ABMA3 1 USER MANUAL Document Number 20 320 12 Issue 03 ...

Страница 2: ...s the property of Austdac Pty Ltd It is subject to its recall and must not be reproduced in part or whole or its contents divulged to third parties without prior written approval from Austdac Pty Ltd TABLE OF CONTENTS TABLE OF CONTENTS 2 PHOTOGRAPHS 2 FIGURES 2 1 GENERAL DESCRIPTION 3 2 OPERATIONAL DESCRIPTION 5 Pre start Alarm PSA 5 Detection of Speech for Speaker Mute Control 5 SPEAK key 5 CALL ...

Страница 3: ...ovide the voice communications interface for staff working along the conveyor belt A conversation with another worker along the conveyor belt can be initiated by pressing the call local button once or several times The call local button is used to signal or attract the attention of workers along the conveyor The call local button can be pressed and released to sound a series of beeps along the con...

Страница 4: ...xpose the battery charge current select jumper In the LO position the battery charge current is 11mA and 22mA in the HI position Refer to the system drawing for the correct charge rate for your intercoms Generally the HI position is used in systems with short powered segments and fewer intercoms the LO position is used in long powered segments with more intercoms Photograph 3 Battery type 5 NH 1 N...

Страница 5: ...at a DC voltage level between the system supply voltage and the supply voltage minus one volt If the DC voltage level on the V line with respect to the R line is changed to a value greater than six volts the pre start alarm controller will issue a CALL EXCHANGE tone 194Hz for about 4 seconds This CALL EXCHANGE tone is transmitted to all intercoms and the surface exchange pair This tone triggers a ...

Страница 6: ...upling between shield and the V and S cores has the effect of giving alternative PSA signal paths that can cause the PSA Controller and ABMA3s to receive false confirmations on tail end units 4 CERTIFICATION The intercom type ABMA3 1 has been certified for use as part of the Pre Start Alarm and Communication System type PSACS1 The ABMA3 1 may be used within any PSACS1 system in accordance with the...

Отзывы: