3 INSTALLATION 

Please read all these instructions thoroughly before starting installation.  
 
Check the certification regarding the type of cable that is allowed to be used for installation. 

PRE-INSTALLATION 

IMPORTANT WARNING - Gland Specifications 

Glands are supplied. All glands and blanking plugs should be rated at IP55 or better to maintain case sealing 
integrity. 

   

ALL POSSIBLE MEASURES MUST BE TAKEN TO ENSURE WATER, FLUID OR DUST DOES 
NOT CONTAMINATE THE INTERNAL COMPONENTS OF THE TELEPHONE WHILST 
UNPACKING, PREPARING AND INSTALLING IT IN INCLEMENT WEATHER CONDITIONS OR 
BY NEGLIGENCE. 

FAILURE TO TAKE THIS PRECAUTION WILL INVALIDATE YOUR WARRANTY AND MAY 
INVALIDATE THE CERTIFICATION OF THE TELEPHONE. 

IF ONLY ONE CABLE GLAND ENTRY IS USED, A SEALING PLUG MUST BE FITTED TO THE SECOND 
GLAND POSITION.  

 

THE TELEPHONE POLYESTER ENCLOSURE MUST NOT BE OPENED IN THE HAZARDOUS AREA!

 

3.1 MOUNTING DETAILS 

Mounting the telephone can be made by either fixing points ‘A’ or ‘B’ as shown in figure 2. 
For option ‘A’ use 3 x 8mm diameter screws with suitable plugs for the wall type to be installed 
upon. 
For option ‘B’ use 4 x M6 x 1.0 bolts.  
 

  

 

 

Figure 2.

 

Содержание A103

Страница 1: ...1 1 O OF F 1 15 5 Title AUSTDAC MINE TELEPHONE TYPE A103 USER S MANUAL Document Number 27 225 12 Issue 01 ...

Страница 2: ...4 Packard Avenue Castle Hill NSW 2154 Australia PO Box 6486 Baulkham Hills Business Centre NSW 2153 Australia Phone 61 2 8851 5000 Fax 61 2 9899 2490 Website www austdac com au Austdac Inc 455 Lowries Run Rd Pittsburgh PA 15237 USA Phone 1 888 254 9155 Fax 1 412 635 0179 Copyright 2013 05 22 This document remains the property of Austdac Pty Ltd It is subject to its recall and must not be reproduce...

Страница 3: ...Function 6 3 INSTALLATION 7 Pre installation 7 3 1 Mounting details 7 3 2 Termination 8 4 External Signalling OPTIONAL relay not fitted as standard 9 5 Internal BP004 battery connection 9 6 Programming and configuration changes 9 6 1 Programming an emergency number or Emergency Tone 10 6 2 Factory settings for DTMF 11 6 3 Assembly of Telephone on to Installed Base 11 7 MAINTENANCE 12 7 1 Battery S...

Страница 4: ...AMINATE THE INTERNAL COMPONENTS OF THIS TELEPHONE WHILST UNPACKING PREPARING AND INSTALLING FAILURE TO CARRY OUT THIS PRECAUTION WILL INVALIDATE CERTIFICATION AND YOUR WARRANTY PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING INSTALLATION THIS IS A CERTIFIED PRODUCT CONFIGURATION AND INSTALLATION SHOULD BE CARRIED OUT BY A COMPETENT PERSON ANY CONFIGURATION ADJUSTMENTS SHOULD BE CARRIED O...

Страница 5: ...olete A101 and A102 telephone The A103 telephone comprises of a carbon loaded glass filled polyester telephone encased in a metallic surround which also contain the customer termination box referred to as the terminal chamber throughout this document Note The A103 telephone contains a BP004 which is an ATEX IECEx certified rechargeable battery only for use in GAI Tronics telephones This battery wi...

Страница 6: ...nging will be heard from the speakers and the strobe will flash Press and release the DA button to go off hook lift the handset and talk as before with the PTT operated or lift the handset and operate the PTT will also answer an incoming call Note After a call duration of 90 seconds the A103 telephone will sound a series of 5 beeps indicating to the user that the call is about to be terminated Thi...

Страница 7: ...OSSIBLE MEASURES MUST BE TAKEN TO ENSURE WATER FLUID OR DUST DOES NOT CONTAMINATE THE INTERNAL COMPONENTS OF THE TELEPHONE WHILST UNPACKING PREPARING AND INSTALLING IT IN INCLEMENT WEATHER CONDITIONS OR BY NEGLIGENCE FAILURE TO TAKE THIS PRECAUTION WILL INVALIDATE YOUR WARRANTY AND MAY INVALIDATE THE CERTIFICATION OF THE TELEPHONE IF ONLY ONE CABLE GLAND ENTRY IS USED A SEALING PLUG MUST BE FITTED...

Страница 8: ...3 2 TERMINATION Connection should only be made to a Safe Telephone System either the ST1 or ST2 series exchanges The telephone may be connected as 1 2 or 3 telephones per line See the reverse side of the termination chamber cover for wiring details There are limitations on distance when 2 or more phones are connected together Fig 3 terminal block Fig 4 Telephone parallel connection diagram ...

Страница 9: ...spatch from the factory to prevent full discharge It will therefore need to be reconnected during the installation process before securing the termination chamber cover To reconnect the battery simply connect the 4 pin socket and plug inside the termination chamber together Note The battery should be fully charged before use If the battery needs to be recharged see section Battery SAFE AREA tests ...

Страница 10: ...mber of up to 17 digits To program Emergency E button with a number Press and release the DA key to make the telephone go off hook Press the store button located on the main PCB see figure 5 A short beep should be heard Enter the required digits Press store button again Again a short beep should be heard Finally press the Emergency E button the telephone will sound a longer beep indicating that th...

Страница 11: ...y changing the position of the jumper links located on the main PCB which is inside the polyester telephone enclosure rear casing To prepare for installation undo the three retaining screws shown to remove the front casing from the rear The screws are not captive in the front casing a 5mm Allen key is required Note Do not remove the polyester telephone enclosure rear from the metallic surround as ...

Страница 12: ...is located within the termination chamber Depending on usage and environmental conditions a good battery will indicate a no load voltage of between 7 2 and 8 volts If the battery needs to be replaced carry out the following Isolate the line feeding the A103 so that no power is being applied before removing the termination chamber cover Once the cover has been removed disconnect the battery plug No...

Страница 13: ...t in a safe area To fully charge a battery Us the Austdac Battery charger part number BATT032 this charger can charge 4 batteries at the same time Note The battery should be replaced if after being charged the voltage remains below 7 2 volts 7 2 PROCEDURES A programme of regular external visual inspection and cleaning is recommended with particular attention being paid to Security of the installat...

Страница 14: ...rob24a Battery Charger 4 way BATT032 9 Recycling Information The symbol shown here and on the product means that the product is classed as Electrical or Electronic Equipment and should not be disposed with other household or commercial waste at the end of its working life The Waste of Electrical and Electronic Equipment WEEE Directive has been put in place to recycle products using best available ...

Страница 15: ...LE EP PH HO ON NE E 1 15 5 O OF F 1 15 5 2 27 7 2 22 25 5 1 12 2 T TY YP PE E A A1 10 03 3 U US SE ER R S S M MA AN NU UA AL L I Is ss su ue e 0 01 1 10 Certificate of Conformity A complete copy can be obtained from the web site or from Austdac ...

Отзывы: