Aurora Archer IS007 Скачать руководство пользователя страница 30

OPERATING INSTRUCTIONS CHECKLIST 

BEFORE OPERATING THIS APPLIANCE, CAREFULLY 
PROCEED THROUGH THE FOLLOWING CHECK LIST. 

1. 

 

Read and understand these instructions before installing or operating this  

 appliance. 

 
2. 

 

Installation of this appliance is only to be carried out by a licensed gas fitter who 

 

 

preferably should be familiar with the installation of the Archer Heater. 

 
3. 

 

Installers who are not familiar with the installation of this appliance should  

 

 

contact Aurora Climate Systems prior to installing the appliance to avoid  

 

 

creating hazardous operating conditions. 

 
4. 

 

No deviations on installation are allowed, unless they are specifically approved in 

 

 

writing by the manufacturer of the appliance. 

 
5.   Wrongful 

or 

deviations 

taken by the installers on the installation of this  

 

 

appliance, will result in the heater not starting up or operating incorrectly  

 

 

causing a safety hazard and will void the manufacturer’s warranty of the  

  appliance. 
 
6. 

 

Check and inspect the appliance for gas leaks. In the event of gas leaks, cut off the 

 

 

gas supply to the heater immediately and call your gas supplier or installer. 

 
7. 

 

Check and verify that all flue venting combustion air intakes and flue cowl are 

  unobstructed. 
 
8. 

 

Refer to page 13 for Single Flue pipe and page 14 for Co-Axial Flue installations, 

 

 

that correct flue pipe and cowl has been fitted in line with the manufacturer’s  

 

 

specifications as illustrated in the Installation Manual Pages 13-20. 

 
9. 

 

Do not use alternative Flue or Cowl on installation other than that specified in 

 

 

this manual - otherwise heater will malfunction and cause hazardous operating 

 

 

conditions and will void the manufacturer’s warranty. 

 
10.   

Check and verify that flue pipe connection to the appliance when using single 

 

 

40mm flue pipe installation is correctly installed and secured in line with  

 

 

instruction in the Installation Manual Pages 16-20. 

29 

Содержание Archer IS007

Страница 1: ...IONS SAI Global Approval No GSCS20025 Australian Patent PN 200110001S Effective January 2009 Serial Number B D Number Model IS700 IS007 Aurora CLIMATE SYSTEMS A B N 43 108 083 987 PLEASE KEEP THESE IN...

Страница 2: ...am 25 Safety Screen Installation 26 Insert Surround 27 OPERATING INSTRUCTIONS Automatic Humidifier Operation 28 Operating Instructions Checklist 29 30 Lighting Instructions 31 Fan Operation 32 Shutdow...

Страница 3: ...ns Or if you wish clarification of the instructions contained in this manual please contact Aurora Climate Systems on telephone 03 9795 8895 or facsimile 03 9701 2088 Note As the Archer Gas Log Space...

Страница 4: ...R GAS LOG SPACE HEATER Note If this appliance is installed by a licensed gas fitter who is not familiar on the installation of the heater we recommend that prior to installing the appliance the instal...

Страница 5: ...HIS APPLIANCE DO NOT ENCLOSE THIS APPLIANCE Aurora Climate Systems A B N 43 108 083 987 71 73 Overseas Drive Noble Park VIC 3174 To be installed by an authorised person in accordance with installation...

Страница 6: ...BSP Gas Connection Inside 4 3 sided Surround 885 x 742 5 Air Inlet Cover Plate 6 PVC Exhaust Pipe 40mm 7 Flue Exit Point centre line 8 Single Flue Adaptor 9 Single Flexi Flue suit 40mm pipe 10 Air In...

Страница 7: ...he appliance to do so will void the warranty Note On Single Wall flue pipe installations imitation zero clearance fireplace a minimum of 25mm clearance must be provided at the rear of the heater to en...

Страница 8: ...ion 0mm D Height Clearance From Unit 15mm 7 Note The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials Aurora Climate Systems recommends that clearan...

Страница 9: ...4 Rear Burner 5 Front Burner NOTE Do not change position of front middle and rear logs as their positions have been present at the factory Changing log positions will result in faulty gas burner funct...

Страница 10: ...and left hand cross logs Remove bottom grill See illustration below Note Please ensure the rear log is sitting hard up against the rear of the firebox at the base and at the top 2 Remove main door The...

Страница 11: ...into position Note Ceramic logs are fragile and so to are the hot surface igniters underneath them and need to be handled with care at all times 6 Position left hand cross log No 5 in position as show...

Страница 12: ...inst the rear at the firebox at the base and at the top B GAS PRESSURE FOR LPG Do not adjust gas burner pressure on LPG Gas burner pressure has been set at factory to required gas burner settings for...

Страница 13: ...ipe installation if the unit and flue pipe is installed in line with the manufacturer s installation instructions Refer installation diagram for single flue pipe installations Pages 13 16 17 18 19 20...

Страница 14: ...ER No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm PVC Pipe 400mm long 1 Supplied with heater 3 90 PVC Bend 1 Supplied with heater 4 40mm PVC Pipe up to 5 1m Supplied by install...

Страница 15: ...the heater Note When connecting 40mm pipe at adaptor end and at cowl end ensure that 40mm pipe is long enough to fit in securely at both ends Failure to do so will cause the flames to go out and the h...

Страница 16: ...place Note Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of app...

Страница 17: ...t be able to be removed easily for servicing Not locked in INTERNAL WALL APPLICATION 1 75mm Cowl 2 Flashing 3 BSP Gas Connection Flexible 4 40mm PVC Pipe Zero Clearance 5 45 PVC Elbow 6 45 PVC Elbow 7...

Страница 18: ...length in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends 90 Elbow 75mm stainless steel cowl to suit 40mm PVC flue pipe External Wall Concrete Slab Internal Wall INSTALLATION INSTRUCTIONS Internal t...

Страница 19: ...m PVC pipe 5100mm with 1 x 90 and 2 x 45 bends Caution To avoid water trap in Flue system 40mm PVC pipe must be supported every 2 metres to avoid PVC pipe sagging and PVC pipe must have fall to ground...

Страница 20: ...lexible Hose Nylaflow G P Hose Code AH50WAS Supplied with Flue Kit SFA002 Note I D Inside Diameter Flange attached to heater s exhaust fan Supplied and fitted to heater Note If adaptor not fitted dril...

Страница 21: ...ue pipe being forced downwards Supplied by Installer Gas Cowl Supplied in flue kit For safety install gas cock next to appliance Use 1 2 gas loop or part loop in 1 2 copper pipe to allow unit to be re...

Страница 22: ...wo burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater The most common way this button is used is having the Rem...

Страница 23: ...ng Remote Control Please Note The front panel must be opened for this wiring to occur The front panel simply pulls forward no tools required Caution When removing front panel as there are low voltage...

Страница 24: ...met supplied over gas line and insert into back panel IMPORTANT Note The copper gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from it...

Страница 25: ...s pressure Note Gas burner pressure can only be adjusted on high burner setting with both switches medium and low burner in the ON position and flames holding on both burners B represents the test poi...

Страница 26: ...14 WAY RIBBON TO DISPLAY 1 CONV FAN BLUE 2 TR PRIMARY BLACK TR PRIMARY WHITE 8 1 N C 2 3 1 TRANSFORMER 12V AIR PRESSURE SWITCH REAR BURNER SWITCH PIN 5 FRONT BURNER SWITCH TRANSFORMER 240V PIN 18 PIN...

Страница 27: ...NS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MA...

Страница 28: ...e when fitting the surround to heater FITTING OF LOUVRE Place the louvre in the surround as shown in Diagram A and fasten with the six screws supplied as shown in Diagram B DIAGRAM B FITTING OF SURROU...

Страница 29: ...e automatic humidifier pump comes on to pump condensate into the stainless steal tray located on the top of the heater the L E D light Item 10 on the front panel will light up and flash for the durati...

Страница 30: ...operating incorrectly causing a safety hazard and will void the manufacturer s warranty of the appliance 6 Check and inspect the appliance for gas leaks In the event of gas leaks cut off the gas supp...

Страница 31: ...s fitted as heater will not operate 14 For your personal safety check and verify that polarities are correct in the power supply to the heater Also check for proper earth connections at the power sour...

Страница 32: ...ight and the convection fan will blow warm air from the heater as the heater becomes warmer the medium L E D Item 8 will come on and when the heater has reached its highest operating temperature all t...

Страница 33: ...te It can take up to approximately 20 30 minutes before the fan speed will change and settle on the next setting The firebox temperature and the outside ambient temperature will regulate how quickly t...

Страница 34: ...IRING The first fire in your heater is part of the paint curing process Your Archer Gas Log Space Heater has been painted with the highest quality heat resistant silicon paint available in the world T...

Страница 35: ...for the heater to do in certain situations Eg Overheating power failure or dips windy conditions pump failure partial or full blockage of flue pipe or no gas All of these operations are monitored by t...

Страница 36: ...ced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently Note If the main convection fan becomes clogged with lint and dust an over temperature sit...

Страница 37: ...y Stainless Steel doors can be cleaned with a metal cleaner that can be used on Stainless Steel Please note Stains or imperfections on plated finishes are not covered under warranty Caution Do not use...

Страница 38: ...d Qualifications below for further information on product coverage CONDITIONS EXCLUSIONS AND QUALIFICATIONS Repair and replacement work will be carried out by the approved Service Agent of Aurora on t...

Страница 39: ...tion or functionality check Freight or postage both ways is to be paid by the owner If Aurora finds a fault with the device they will repair or replace it under the normal warranty terms 1 Year It mus...

Страница 40: ...11 Sooting up of heater Note For heaters operating on LPG to avoid sooting up of heater LPG bottle must not be run empty For best practice LPG bottles should be refilled after 75 of fuel has been use...

Страница 41: ...ion for the learn process to occur The burner switches and the red button must all be in the OFF position When removing or replacing the front panel ensure no wires are disconnected broken or pinched...

Страница 42: ...normal No If the glass has sooted up that you start having difficulty seeing through it this is not normal Nor is having large build up of soot forming on the logs Please note It is normal for some so...

Страница 43: ...NOTES 42...

Страница 44: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING INSTALLATION INSTRUCTIONS TO THE CONSUMER FOR FUTURE REFERENCE DATE OF PURCHASE...

Отзывы: