Technical Information
no.
912-100-0108
page
5/11
status: 14.07.05
7 Electrical connection
Electrical connection diagram
see according drawing of the heater
cable specification:
FLRY 1,5 mm
2
8 Maintenance
The heater is maintenance-free. To assure an optimal function for a long period
we recommend a regularly check of:
- hoses for chaffing and kinks, damage and porosity
- the fixing, leak control and laying of the hoses and fittings.
The hose fixings are to be tightened if necessary.
- the electrical connections on the correct state and firm position
Cooling water circuit:
When refilling the cooling water quality has to be considered. When using
AURORA water valves the warranty expires when defects occur due to
contamination in the water circuit. (see TI 971-190-0003 anticorrosion/antifreeze
solution. Please order in the case of need)
9 Spare parts
spare parts list for Trolly 151-701/702-0000, 151-701/702-0003, 151-701-0011,
151-701-0013, 151-701-0014, 151-701-0015, 151-701/702-0016, 151-701-0017
description
part no.
12V
part no.
24V
heat exchanger
∅
15 mm
283-701-0001
283-701-0001
twin radial blower DRG 370
131-101-0061
131-102-0061
resistor
413-300-0001
413-300-0002
cable set 2-speed
217-100-0008
214-700-0013
socket
∅
55 mm
431-420-0014
431-420-0014
spreading rivet
494-500-0013
494-500-0013
spare parts list for Trolly 151-701/702-0001
description
part no.
12V
part no.
24V
heat exchanger
∅
15 mm
283-701-0001
283-701-0001
twin radial blower DRG 370
131-101-0061
131-102-0061
cable set 1-speed
214-700-0011
214-700-0011
socket
∅
55 mm
431-420-0014
431-420-0014
spreading rivet
494-500-0013
494-500-0013