Technical Information
no.
912-100-0108
page
4/11
status: 14.07.05
•
Take note of the installation location in the cab. Install the unit according to
the space available at the most appropriate spot on the mounting points
provided.
•
The fixing points must be level to avoid strains in the unit housing.
Consequences
The function of the unit can be impaired if you don’t follow this advice. The unit
housing may even become damaged.
If water gets into the unit its function can also be impaired under certain
circumstances. You should therefore fit the unit at a location which is protected
from water.
Please pay attention to the actual technical supplement to the general terms of
sale and the safety instructions in contact & Info of www.aurora-eos.com.
Take care of the mounting position of the Trolly. The axis of the blower motor
must be in a horizontal position.
Before installation of the device the electrical connection and the water
connection are to be set up.
The warm air hoses are pushed over the heaters sockets. According to the
installation situation it may be necessary to provide additional means of fixing
the warm air hoses using a worm drive hose clip over the sockets.
It is essential to use appropriate worm drive hose clips for connecting the warm
water hoses to the heat exchanger.
The fixing of the heater is made with screws to the mounting links slotted holes
7x10 mm of the housing sheet.
5 Operation
The operation is made with vehicle side operation elements.
AURORA can deliver a Control Panel (accessories) for the operation.
6 Technical data
Technical data for the standard versions 151-701-0000 and 151-702-0000:
•
V
water
= 1000l/h
test voltage
. 13 V / 26 V
blower
speed
•
V
air
[m³/h]
•
Q
80
[kW]
P
el
[W]
L
P
[dB(A)]
±
±
±
±
0,5
2
344
6,5
128
73
1
238
5
69
64