12V Diaphragm Water Pump - PRP-125  

 

Plumbing 

 

Use flexible hose of a pressure rating that is compatible with the fluid to be pumped. The pump is 
not designed to be connected directly to rigid pipes/tubes. 

 

Tubing should be a minimum of 9.5mm (3/8") internal diameter (ID) and at least 500mm (20”) in 
length to avoid excess stress on the pump parts. 

 

Do not crimp or kink the tubing. 

 

The use of check valves in the plumbing system could interfere with the priming ability of the pump. 
If a check valve is installed, it must have a cracking pressure of no more than 2 PSI (0.14bar). 

 

Use a minimum 40-mesh strainer or filter in the pump inlet line to prevent foreign debris from 
entering the pump. Failures due to foreign debris entering the pump will not be covered under 
warranty.  

 

The pump comes with 90° tube connectors that can be used for easier 
plumbing. To attach, firmly push the large diameter end of the 90° connector 
to the required connector, then push the “U” clip through the holes in the 
connector to secure. 

Connector tubes to connectors and secure with appropriate clamps/clips. 
The direction of flow is shown below: 

 

 

Electrical Connection 

The pump should be wired to an individual (dedicated) circuit, controlled with a certified double-pole 
switch rated at or above the fuse ampere indicated on the pump motor label. 

The red lead connects to the power source positive 

+

 terminal. The black lead is ground and connects 

to the power source negative 

-

 terminal. Use minimum AWG T6 wire. Use a 5A fuse to protect the 

system wiring and components. 

Содержание PRP-125

Страница 1: ...12V Diaphragm Water Pump PRP 125 User Manual Revision 1 0 September 2016 RETAIN THIS MANUAL FOR FUTURE REFERENCE PLEASE READ THIS MANUAL CAREFULLY BEFORE USE...

Страница 2: ...low all electrical and safety codes Make certain the power source conforms to the pump voltage requirements Ensure that all power sources are disconnected before installing the pump Improper duty cycl...

Страница 3: ...nstallation 4 Mounting 4 Plumbing 5 Electrical Connection 5 Operation 6 Start Up 6 Demand Operation Intermittent Duty 6 Bypass Operation If Equipped 6 Maintenance and Troubleshooting 7 Disassembly Ass...

Страница 4: ...ffects It is intended for intermittent duty cycles but can also be run continuously for short periods of time The higher the duty cycle the shorter the expected life of the pump Typical pump usages in...

Страница 5: ...ntering the pump Failures due to foreign debris entering the pump will not be covered under warranty The pump comes with 90 tube connectors that can be used for easier plumbing To attach firmly push t...

Страница 6: ...configuration Start Up To start and prime the pump the outlet line must be open allowing any in the pump to escape This is to avoid the possibility of airlock The pressure switch will shut off the pum...

Страница 7: ...essure switch cover screw 1 and then remove the cover 8 3 Disconnect the red wires 5 from the pressure switch 4 Remove the screws 2 from the front of the pump head 3 5 Slide the pump off the motor 4 a...

Страница 8: ...let tubes and connections and ensure they are air tight Debris in the check valve Clean obstructed or jammed check valves Ruptured pump diaphragm Replace pump diaphragm Defective pump check valve Repl...

Страница 9: ...pump diaphragm Defective pressure switch Replace pressure switch Low Flow Rate and Pressure Possible Fault Action Air leak at the pump intake Check inlet tubes and connections and ensure they are air...

Страница 10: ...10 Technical Specifications Inlet 10 mm or 1 4 hose fitting Outlet 10 mm or 1 4 hose fitting Flow 1 6 GPM 6L min Volts 12V 9 to 14 4V Amp Draw 2 1A Max 6A Pressure 80 PSI Motor duty cycle will vary w...

Страница 11: ...ining course before being given access to the product The product has been supplied by a general merchandise retailer that may not be familiar with your specific application or your description of the...

Отзывы: