                                                                     WIZ2-434 

                                                                                                                                   Instruction Manual

 

Technical features are subject to change without notice. AUR°EL S.p.A does not assume responsibilities for any damage caused by the device’s misuse. 

 
AUR°EL S.p.A.

 Via Foro dei Tigli, 4 - 47015 Modigliana [FC] – ITALY                                                                  Rev. D, 31-01-2003 

Tel.: +390546941124 – Fax: +390546941660                                                                                                           Page  3 of 14 

http://www.aurel.it

  -  email: 

[email protected]

 

 
Introduction 

 
WIZ2-434-x modules allow to connect, via radio, two or more units; they supply a complete radio frequency 
system, by integrating receiver, transmitter and antenna and by indipendently administrating a low level 
packaging of the data sent from a control unit (for instance a Personal Computer), and the managing 
functions of the radio link interconnection. 
They are supplied by a voltage ranging from 9 to 15V. 
 

 
A 96 bytes maximum length data packet can be sent to the transmitter module by a personal computer; the 
data to be transmitted are memorized in an input buffer and forwarded to the remote connected WIZ2 
module, to which are addressed. 
 
The packet received by the WIZ2 module will be decoded, stored in the reception buffer and, in case, 
confirmed. It shall be forwarded, then, to the downstream connected unit, through a serial port. 
 
The WIZ2 modules bear a 

polling

  system where a master unit can address up to 255 slave units. 

 
The host personal computer dispatches, to the WIZ2 module, the data preceded by an address byte of the 
remote module; the data exchanging administration unit adds the preamble and error control bytes.  
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

HOST PC 

 WIZ2-  master 

 WIZ2-  slave 

REMOTE Units 

TX/RX 

Содержание WIZ2-434

Страница 1: ...RS232 12V logic 9 15V supply WIZ2 434 RSB same as above but in a plastic shell The WIZ2 434 x modules are intelligent transceivers that support a digital data packet transfer of any length 1 96 bytes...

Страница 2: ...6941660 Page 2 of 14 http www aurel it email lab el aurel it TABLE OF CONTENTS INTRODUCTION 1 WIZ2 434 RS MODULES LAYOUTS 2 ADDRESSING 2 1 CONVERSATION ADMINISTRATION BETWEEN UNITS 2 2 MASTER AND SLAV...

Страница 3: ...nctions of the radio link interconnection They are supplied by a voltage ranging from 9 to 15V A 96 bytes maximum length data packet can be sent to the transmitter module by a personal computer the da...

Страница 4: ...f 14 http www aurel it email lab el aurel it 1 Lay out The WIZ2 434 RS model foresees a 9 15V voltage range supplied to the DC 1 connector and signals in RS232 logic on the female 9 pins D 2 connector...

Страница 5: ...imum slave number The distinction between master and slave units is of software type according to the address contained in the ADDRESS register ADDRESS 0 system s MASTER module ADDRESS 1 255 SLAVE mod...

Страница 6: ...he WIZ2 remote module it is then forwarded to the unit connected to it reproducing the original data string without the front placed address 4 If the data sent by the master were for instance a comman...

Страница 7: ...an integer number binary configuration 00000100 and not as an ASCII type 4 which corresponds to a decimal value 52 whose binary configuration is 00110100 It is suggest to pay attention to the convers...

Страница 8: ...be programmed through the serial port by closing the jumper 3 and supplying subsequently the module The programming mode foresees to enter a WRITE or READ type command Here below is reported the list...

Страница 9: ...he programming string is composed by a 2 bytes sequence ASCII type 24 which enables the microcontroller to receive a command of a register reading address_register is the address of the register to be...

Страница 10: ...packet is considered effectively addressed to this WIZ2 unit A WIZ2 slave module places its own address before the data packet that has to be transmitted via radio The default value of the ADDRESS re...

Страница 11: ...31 01 2003 Tel 390546941124 Fax 390546941660 Page 11 of 14 http www aurel it email lab el aurel it The register s contents may be changed by entering the command 3 new_value To read the register s co...

Страница 12: ...546941660 Page 12 of 14 http www aurel it email lab el aurel it 4 Programming Jumpers To reach the 3 programming jumpers carefully remove the front cover of the box RSB model By closing JP3 from DATA...

Страница 13: ...als between connected units with an RS232 protocol are not utilized by WIZ2 modules During the via cable programming phase para 3 3 the RTS and CTS lines are used The connection cable with the master...

Страница 14: ...B MASTER AND SLAVE MODULES THEIR USE IN A POLLI NG TYPE QUESTIONING SYSTEM In a polling system the unity connected to the master module administrates the slaves questioning sequence deciding the timin...

Отзывы: