APPENDIX A: CONNECTIONS 

 

A.1 RS232 SERI AL CONNECTI ON

 

 
The WIZ2 modules converse with external devices through a 9 pins RS232 serial interface.  
The handshaking signals between connected units, with an RS232 protocol, are not utilized by WIZ2 
modules. 
 
During the via cable programming phase, (para. 3.3) the RTS and CTS lines are used. 
 
 
 

 
The connection cable with the master unit must be pin-to-pin, the one connected with the remote unit, could 
be null-modem (see A.2) 
 
 

Pin  Signal ( PC)     

I nput/ Output ( WI Z2)  

Usage in WI Z2 

DCD 

Data carrier Detect 

 

 

RX 

Receive Data 

Output 

Tx data to PC unit 

TX 

Transmit Data 

Input 

Rx data from PC unit 

DTR 

Data Terminal Ready 

 

 

GND 

Ground 

Ground 

DSR 

Data Set Ready 

 

 

RTS 

Request To Send 

Input 

Not used 

CTS 

Clear To Send 

Output 

Not used 

RI 

Ring Indicator 

Input 

 

 
   
 
 
 
 
 

 
 
 

1

9 PINS CONNECTOR 
(female) 

View of the connector fitted on the 
WIZ2 module 

Содержание WIZ2-434

Страница 1: ...RS232 12V logic 9 15V supply WIZ2 434 RSB same as above but in a plastic shell The WIZ2 434 x modules are intelligent transceivers that support a digital data packet transfer of any length 1 96 bytes...

Страница 2: ...6941660 Page 2 of 14 http www aurel it email lab el aurel it TABLE OF CONTENTS INTRODUCTION 1 WIZ2 434 RS MODULES LAYOUTS 2 ADDRESSING 2 1 CONVERSATION ADMINISTRATION BETWEEN UNITS 2 2 MASTER AND SLAV...

Страница 3: ...nctions of the radio link interconnection They are supplied by a voltage ranging from 9 to 15V A 96 bytes maximum length data packet can be sent to the transmitter module by a personal computer the da...

Страница 4: ...f 14 http www aurel it email lab el aurel it 1 Lay out The WIZ2 434 RS model foresees a 9 15V voltage range supplied to the DC 1 connector and signals in RS232 logic on the female 9 pins D 2 connector...

Страница 5: ...imum slave number The distinction between master and slave units is of software type according to the address contained in the ADDRESS register ADDRESS 0 system s MASTER module ADDRESS 1 255 SLAVE mod...

Страница 6: ...he WIZ2 remote module it is then forwarded to the unit connected to it reproducing the original data string without the front placed address 4 If the data sent by the master were for instance a comman...

Страница 7: ...an integer number binary configuration 00000100 and not as an ASCII type 4 which corresponds to a decimal value 52 whose binary configuration is 00110100 It is suggest to pay attention to the convers...

Страница 8: ...be programmed through the serial port by closing the jumper 3 and supplying subsequently the module The programming mode foresees to enter a WRITE or READ type command Here below is reported the list...

Страница 9: ...he programming string is composed by a 2 bytes sequence ASCII type 24 which enables the microcontroller to receive a command of a register reading address_register is the address of the register to be...

Страница 10: ...packet is considered effectively addressed to this WIZ2 unit A WIZ2 slave module places its own address before the data packet that has to be transmitted via radio The default value of the ADDRESS re...

Страница 11: ...31 01 2003 Tel 390546941124 Fax 390546941660 Page 11 of 14 http www aurel it email lab el aurel it The register s contents may be changed by entering the command 3 new_value To read the register s co...

Страница 12: ...546941660 Page 12 of 14 http www aurel it email lab el aurel it 4 Programming Jumpers To reach the 3 programming jumpers carefully remove the front cover of the box RSB model By closing JP3 from DATA...

Страница 13: ...als between connected units with an RS232 protocol are not utilized by WIZ2 modules During the via cable programming phase para 3 3 the RTS and CTS lines are used The connection cable with the master...

Страница 14: ...B MASTER AND SLAVE MODULES THEIR USE IN A POLLI NG TYPE QUESTIONING SYSTEM In a polling system the unity connected to the master module administrates the slaves questioning sequence deciding the timin...

Отзывы: