MAG 4M 5026
User Manual
Battery substitution
The substitution of the battery must be carried out when the LED of the sensor, independently from alarm
status, it quickly blinks for two seconds each 5 minutes(alarm signal for discharged battery).
In this case the battery is not completely finished and it can ensure a couple of weeks of working.
For the replacement procede as follow:
Remove the cover and replace the litium 3V mod. CR2032 battery paying attention to the polarity, see
picture number 6.
In order to get a longer life time, the choise of 5 years deadline battery is advised. The accidental reversal of
polarity of the batteries does not cause the breaking of the circuit and discharging them. In the case of
loosing of substances , remove it taking care to not get in contact with them. Throw used batteries in
respect of the normative. See the section 'Information for users'.
Fig. 6 – Battery substitution
Technical features
Min Typical Max U.M.
Electrical parameters
Voltage supply (1)
2,1
3,0
3,6
Volt
stand-by current supply
3 Volt power supply
3
uA
Current supply during alarm
3 Volt, led on, radio transmission on
7
mA
Low battery voltage consumption
2,25
2,3
2,35
Volt
Radio transmission
Standard frequency OOK modulation
433,92
MHz
Effected Radiated Power
1
mW
ERP second harmonic < 1GHz
-36
dBm
ERP third harmonic > 1GHz
-30
dBm
Radio coding CI 145026
Electromagnetic immunity
10
V/m
The technical features can be change without forecast. AUR°EL S.p.A doesn’t assume any responsibility for the demages due to the improper use.
AUR°EL S.p.A.
Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY Rev.A 11.06.2014
Tel.: +390546941124 – Fax: +390546941660 Page 4 of