HOW IT WORKS

Jumpers 1 and 2 (see JP1 and JP2 in picture one) allow to set several kind of works for test and alarm
phase

.

FUNCTION

JP1

JP2

RADIO MODE

CLOSE

OPEN

CALIBRATION FOR MAGNETIC SENSOR

OPEN

CLOSE

NORMALY WORKING

X

X

RADIO MODE:  

It’s a function used during learning procedure to get the radio code in the matched

receiver and to verify the quality of the radio connection. It starts from the closing of JP1 contact and
opening JP2.
The radio transmission is active for 30 seconds, modulated with a code set in the dip-switch(“LEARNING
AND RADIO TEST”).
At the end of transmission the magnetic contact goes in main working mode.
To start again the transmission, disconnect and fit again the JP1 contact.

CALIBRATION OF MAGNETIC SENSOR

:

 

It’s a function used during learning procedure of the

sensor that helps the installer to place the permanent magnet near the magnetic contact.
It is triggered by the closure of JP2 and JP1 open, the LED switches on when the magnet closes the
magnetic contact and switches off when the contact opens. No radio transmission is activated.
After five minutes from the starting of the procedure, the sensor will come back to the normal function. 
To start again the function, disconnect and fit again JP2 contact

.

MAIN WORKING:

 

Normally is activated after the fitting of the battery or when “RADIO MODE” AND

“CALIBRATION OF MAGNETIC SENSOR” functions are finished. 
The sensor sends a code set by dip-switch when the magnet is removed(see the paragraph “Code radio
features”) .
LED switches on for 100ms to show the radio transmission.
Note: The closing of the magnetic contact is not shown in anyway.
 

Luminous signal

Within the MAG 4M 5026 is present a red led which shows the follow functions:
It switches on  in presence of any radio transmission( alarm signal, radio test).
In the case of discharge battery (under 2,3 V voltage level) it quickly blinks for two seconds each five
minutes.
In the “calibration of magnetic sensor” function , it switches on permanently if the magnetic contact is
closed.

The technical features can be change without forecast. AUR°EL S.p.A  doesn’t assume any responsibility for the demages due to the improper use.

AUR°EL S.p.A.

 Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY                                                                           Rev.A  11.06.2014

Tel.: +390546941124 – Fax: +390546941660                                                                                                                              Page  2 of
7

http://www.aurel.it

  -  email: 

[email protected]

                                                                         

Preliminary

Содержание MAG 4M 5026

Страница 1: ...D the alarm of discharged battery The radio transmission operates in the 433 92 MHz ISM band with fixed coding settable by a 9 tree state vias dip switch features as shown in CI 145026 It starts when...

Страница 2: ...ssion is activated After five minutes from the starting of the procedure the sensor will come back to the normal function To start again the function disconnect and fit again JP2 contact MAIN WORKING...

Страница 3: ...gnetic contact However the sensor will not be installed at a distance greater than 30mm from the permanent magnet Learning procedure and radio test Prepare the receiver side in the learning mode Activ...

Страница 4: ...ing care to not get in contact with them Throw used batteries in respect of the normative See the section Information for users Fig 6 Battery substitution Technical features Min Typical Max U M Electr...

Страница 5: ...f the dip switch will be ignored The radio code is unique that one set by dip switch and it starts when the magnet is removed by the enclosure or at the activation of the RADIO MODE procedure In order...

Страница 6: ...EN 300 220 1 V2 3 1 Radio features EN 60950 Other features The technical features can be change without forecast AUR EL S p A doesn t assume any responsibility for the demages due to the improper use...

Страница 7: ...system and all its components subsystems and consumables materials that are part of the product when you take the decision to discard them must be thrown to collection centers for proper treatment of...

Отзывы: