AURATON S03 RT Скачать руководство пользователя страница 1

S03 RT

USER’S MANUAL

EN

Содержание S03 RT

Страница 1: ...S03 RT USER S MANUAL EN ...

Страница 2: ...central heating pump controller AURATON S03 RT The AURATON S03 RT controller is tended for wireless control of a central heating CH pump Before you start using the controller please read this instruction carefully ...

Страница 3: ...auses faster cooling of the water in the boiler faster than in the radiators The optimum temperature can be set on the controller s scale most often 40 C In a CH system with a gas boiler the temperature set on the controller must be lower than the temperature set on the CH boiler If the temperature is set on the controller above the dew point it prevents condensation in the boiler during the heati...

Страница 4: ...ure increase button a temperature decrease button an LCD display a confirmation or controller on off button a button for the reduction of the programmed pump shutdown temperature mode AntyStop mode by pressing the button for a short time you can confirm the temperature setting by holding the button you can switch the controller on off ...

Страница 5: ...room where it is installed 2 Discharged battery The indicator is displayed when the permissible minimum battery voltage level is exceeded The battery must then be replaced as soon as possible NOTE In order to maintain the controller settings the battery replacement should take not more than 30 seconds ...

Страница 6: ... 4 Temperature unit C This indicates that the temperature is displayed in degrees Celsius 5 Activated pump indicator A pictogram that indicates the operating status of the pump It is displayed when the controlled device is switched on 6 Transmission symbol Indicates communication with the receiver ...

Страница 7: ...operate under the load of 16A 10A mounting hole detachable 230V power supply connection terminals detachable control connection terminals mounting hole power button power supply diode button for unpairing devices diode indicating that the actuator device has been switched on diode indicating that the actuator device has been switched off button for pairing devices with the RT receiver ...

Страница 8: ...Pairing the wireless regulator and the RT receiver The LED flashes red the RT receiver awaits the device to be deregistered chapter Deregistering the regulator from the ceiver Green power supply diode the RT receiver is switched on The LED flashes alternating red and green ALARM the RT receiver has lost connection with one of the paired devices chapter Special situations RESET receiver deregisters...

Страница 9: ...s Mounting the controller on a wall In order to mount the controller on a wall 1 Take off the enclosure of the controller 2 Drill two 6 mm diameter holes in the wall 3 Put two wall plugs in the drilled holes 4 Fasten the back part of the enclosure to the wall using the screws provided with the set 5 Put on the controller s enclosure If the wall is made of wood there is no need to use wall plugs On...

Страница 10: ...ordertoleavethe emergency mode the external temperature sensor must be reconnected or the controller must be restarted by simultaneously pressing and holding the and switches for at least 5 seconds After this procedure is completed the controller displays the temperature measured by the internal sensor Mounting the sensor Install the sensor on an uncovered outlet pipe connected to the CH boiler as...

Страница 11: ...iver should be installed by a profes sional NOTE In the permanent system of the building there must be a switch and an overcurrent protection NOTE In order to facilitate installation the terminals are fitted with ex tendable clamps Before cable connections are made they can be disconnected from the controllers The cables may be routed from the bottom of the receiver by breaking out holes in the mo...

Страница 12: ...Follow the ser vice instruction of the heating device The COM common and NO normally opened terminals are used the most often 3 Connect the power supply cables to the terminals of the power supply con nection of the AURATON RT receiver in observance of safety rules 4 After the cables are connected they must be fixed with the cable fastening holder and the covers must be screwed back to the AURATON...

Страница 13: ... fastening screws on the wall 3 In the marked locations drill holes with diameters appropriate for the diameters of the enclosed wall plugs 5 mm 4 Put the wall plugs in the drilled holes 5 Fasten the AURATON RT receiver to the wall using screws so that the receiver is well fastened Note If the wall is wooden there is no need to use wall plugs In such a case drill two holes 2 7 mm in diameter inste...

Страница 14: ...receiver the two devices are factory paired Devices purchased separately must be paired 1 Pairing of the AURATON S03 RT controller with the AURATON RT receiver is initiated by pressing the right pairing button a single sound signal is emitted on the AURATON RT receiver and by holding it pressed for at least 3 s until the LED diode starts blinking with green light double sound signal then the butto...

Страница 15: ...y becomes activated the LED diode is red and after it is switched off it is green NOTE When any button is pressed a short sound signal is emitted Unpairing of the controller and the RT receiver 1 Unpairing of the AURATON S03 RT controller from the AURATON RT re ceiver is initiated by pressing the left unpairing button on the receiver and holding it for at least 3 seconds until the LED diode starts...

Страница 16: ... simul taneously press and hold both the pairing and the unpairing button and for at least 5 seconds until the LED diode starts blinking green and red alternately Then release both buttons Sound signal when the button is pressed a short sound signal is emitted followed by another short signal 5 seconds later Successful completion of unpairing of all devices is signalized after about 2 seconds by t...

Страница 17: ...moment the current temperature in the room is displayed Then the control ler is ready for operation Temperature setting NOTE The first time any function button is pressed the illumination is always switched on first and only then the button s function is activated In order to set the temperature in the nor mal operation mode 1 Press the or button The segment that shows the temperature goes into th...

Страница 18: ... When the setting is e g 40 C and the reduction is set to 1 C the pump shuts down at the tempera ture of 39 C If the reduction is set to 5 C the pump shuts down at 35 C In order to set the reduction temperature press the button the factory setting is 3 C Each time the button is pressed the tem perature setting changes by 1 C in a loop from 1 C to 5 C Confirm the selection by pressing the button NO...

Страница 19: ...ter the heating season is over In order for the system to work after the heat ing season the controller must remain switched on with the AntyStop function active Comments The controller may be switched on or off at any time by briefly pressing the button The first time any function button is pressed the illumination is always switched on first and only then the button s function is activated When ...

Страница 20: ...nnected or defective the controller goes into the emergency mode dashes are shown as the measured temperature which results in the CH pump shutting down until the defect is eliminated This is intended to protect the heating system from overheating In order to leave the emergency mode connect the external temperature sensor back or reset the controller by taking out the battery until the display sw...

Страница 21: ...21 PROTECTIVE The AURATON S03 RT regulator connection schematics PUMP ...

Страница 22: ...pply of the RT receiver 230 V AC 50Hz Radio frequency 868 MHz Range of operation in a regular building with stand ard wall structures approx 30 m in an open field up to 300 m Disposal of the device The device is marked with a symbol of a crossed waste bin Pursuant to European Directive 2002 96 EC and to the Act on waste electrical and elec tronic equipment such a symbol indicates that the device a...

Страница 23: ......

Страница 24: ...www auraton pl ver 20190411 ...

Отзывы: