AURATON 3003 Скачать руководство пользователя страница 13

If for any reason you want to have the temperature in 

the room reduced by 3°C every day at the same time, 
then  you  can  do  it  for  6  hours.  To  reduce  the 
temperature

:

1.

Press the button 

             

 and hold it for 

3 seconds.          

The   display will show the   symbol of 

moon (

  

   ) and the hour counter 

(       

)

2.

The  controller  goes  to  the  temporary 

temperature  reduction  mode  and 
every  day  at  the  same  time  it  will 
reduce  the  temperature  by  3°C  for  6 
hours.

 

2.

Using the           

 

and             buttons set the desired temperature 

in the room with the 0.2°C accuracy

.

 

3.

Confirm your settings by briefly pressing the              button

.

 

Setting the temporary temperature 
reduction mode

13

12

First start of the controller

After a correct placement of batteries 
in  the  compartment  all  segments  will 
appear  on  the  display  for  a  second 
(display test), followed by the software 
version number.
The  current  temperature  in  the  room 
will  be  displayed  after  a  moment. 
The controller is ready for operation.

Setting the temperature 

NOTE

:  T

the display backlight on, only the second pressing activates a 
given function

.

To set the required temperature in the normal operation mode

:

1.

Press the 

      

     or              button. 

The temperature display segment will 
go  into  the  edit  mode  and  will  start 
flashing

.

 

he  first  pressing  of  any  function  button  always  turns 

Содержание 3003

Страница 1: ...AURATON 3003 Owner s Manual for software version F0F 3003 www auraton pl ...

Страница 2: ......

Страница 3: ...chnologicalsolutions AURATON 3003 FrostGuard function protects the room against freezing Option to temporarily reduce the programmed temperature For6hours everydayatthesametime BacklitLCDdisplay Backlit display makes it possible to supervise the device operationeveninpoorlylitrooms LCD ...

Страница 4: ...nel of the enclosure includes a backlit LCD display and fourfunctionbuttons 4 increase temperature button temporary temperature reduction button confirm or controller ON OFF button reduce temperature button ź ź press briefly confirm the temperature setting press and hold controller ON OFF ...

Страница 5: ...roller displays the temperature in the roominwhichitisinstalled 2 Batterylow This symbol appears when the battery voltage has dropped belowtheacceptablelevel ReplacethebatteryASAP NOTE to maintain the settings the battery replacement should lastlessthan30seconds ...

Страница 6: ...the user has programmed the temporary temperature reduction mode It appears when the mode is not currently on but the function of temporary temperature reduction is active more information in the Setting the temporarytemperaturereductionmode section 6 Controlleronindicator Indicates the device status It appears when the controlled equipmentisturnedon 7 Indicatoroftemporarytemperaturereductionmode ...

Страница 7: ...on the internal wall of the building partition wall in a place with air circulation Avoid installing it in the vicinity of heat generating devices TV set heater fridge or in places exposed to direct sunlight Installing the controllerneara door mayalso cause problemsas thecontrollerwill beexposedtovibrations Selecting a correct location for the AURATON 3003 temperature controller ...

Страница 8: ...8 Connecting the leads to AURATON 3003 Toconnecttheleadsremovethefrontpanelasshownbelow 1 2 The lead terminals are on the controller s back wall under the plasticcover cover screw 1 2 1 2 ...

Страница 9: ...s the NC terminalisnotused NOTE Afterconnectingtheleadsreplacetheplasticcover cover Installing replacing batteries The battery compartment is located inside the controller in the front part of the enclosure To place the batteries remove the front panel as shown in the section Connecting the leads to AURATON3003 ...

Страница 10: ...olarity TofastentheAURATON3003controllertothewall 1 Remove the controller front panel as shown in the section ConnectingtheleadstoAURATON3003 2 Drill two 6mm dia holes in the wall set the holes spacing usingthecontrollerrearpanel Fastening the controller on the wall NO COM NC opening for the screw ...

Страница 11: ...enwallyoudon thavetouseexpansionplugs Justdrill the 2 7 mm dia holes instead of 6 mm in screw the bolts directly into the wood FRONT PANEL REAR PANEL Placing the front panel NOTE When replacing the front panel onto the rear panel pay attention to thepinconnectionwhichtransmitsthecontrolsignals Pins Pin socket When replacing the front cover make sure that the pins are insertedintothepinsocket ...

Страница 12: ... temperature in the room will be displayed after a moment Thecontrollerisreadyforoperation Setting the temperature NOTE T the display backlight on only the second pressing activates a givenfunction Tosettherequiredtemperatureinthenormaloperationmode 1 Press the or button The temperature display segment will go into the edit mode and will start flashing he first pressing of any function button alwa...

Страница 13: ...seconds The display will show the symbol of moon andthehourcounter 2 The controller goes to the temporary temperature reduction mode and every day at the same time it will reduce the temperature by 3 C for 6 hours 2 Using the and buttons setthe desired temperature intheroomwiththe0 2 Caccuracy 3 Confirmyoursettingsbybrieflypressingthe button Setting the temporary temperature reduction mode 13 ...

Страница 14: ...hours the controller will revert to the basic temperature setting On the display the moon symbol willbereplacedbythesunsymbol NOTE The temporary temperature reduction mode always starts when the function is activated This means that the possible temporary temperature reduction should be programmed at the time when you want the temperature change to happen Switching off the temporary temperature re...

Страница 15: ...fat20 2 C WithHI4 hysteresis and temperature setting of 20 C the boiler switches on at 19 6 C andswitchesoffat20 4 C To change hysteresis press and simultaneously and hold for 3 seconds When hysteresis change mode is active message HI is displayed Use and tochangehysteresissettings HI2 0 2 C factorysetting HI4 0 4 C HIP PWMmode seechapter PWMmode Press toconfirmyourselection Thecontrollerresumesno...

Страница 16: ...Time Preset temperature Room temperature With these values determined the controller switches the heating device on and off in cycles that enable maintaining temperature as closetothesetpointaspossible CAUTION In PWM mode the controller can switch on the heating device even though the temperature in the room is higher than preset temperature This is because the PWM algorithm tries to maintain the ...

Страница 17: ... time by briefly pressingthe button Thefirstpressingofanyfunctionbuttonalwaysturnsthedisplay backlight on only the second pressing activates a given function During programming failure to press any button for 10 seconds isthesameaspressingthebutton Notes ...

Страница 18: ...aximum load current 16A 250VAC on relay contacts Power supply 2x AAA 1 5V alkaline batteries 0 4 C PWM Disposal The controller bears the WEEE crossed waste bin mark According to the Directive 2002 96 CE and the Waste Electrical and Electronic Equipment Act this marking means that after its life such equipment may not be disposed of together with the householdwaste The user should deliver it to a c...

Страница 19: ......

Страница 20: ...www auraton pl ...

Отзывы: