Rev. A 05/26
AM11MF30-1
6
2. Place the connector inside the electrical housing, and
then place the housing lid. Use screws and the lid
from bag 5, to close the mist control / fan pole
assembly (F-2, F-3). Do not over tighten the screws.
F-2
F-3
OPERATING INSTRUCTIONS
Read this owner’s manual before operating this
product.
1. To operate the misting fan, plug the power cord into
a 120 VAC, 60Hz outlet.
CAUTION:
FAN AND/OR MISTING SYSTEM
MAY START UP WHEN THE UNIT IS INITIALLY
PLUGGED TO THE POWER OUTLET.
2. Fan Operation (ON-OFF, Speed control)
Pull Action
Speed
First
High
Second
Medium
Third
Low
Fourth
“OFF”
3.
Fan Operation (Oscillation Control)
To turn on the oscillation function, press down the
oscillation switch, to stop the function simply pull-up
the oscillation switch. The oscillation angle is
approximately 50
°
(G-1)
G-1
4. Misting Operation
IMPORTANT:
This product is designed to
operate with DRINKING WATER ONLY. Fan
and/or misting system may start up when the unit
is initially plugged to the power outlet.
BEFORE STARTING
• Remove fill cap on power base assembly and fill with
DRINKING WATER through the basket filter until tank
is filled to approximately 1” below the bottom of the
basket filter.
• Add
½
teaspoon of unscented chlorine bleach to the
water tank (approximately 5 drops per gallon of
drinking water).
• Replace cap and hand tighten.
• The misting function of this product is turned on by
simply rotating the switch on the fan pole assembly,
clockwise to PRIME (G-2). Once water begins to flow
from the nozzles rotate the switch back to MIST. It
may take up to 2 minutes for a new misting fan to start
misting, and it is normal for air to come before water.
• Once the system has been primed it does not need to
be primed again unless the system has been
completely drained.
G-2
• Automatic Shutoff
The Misting Fan has a built in safety feature to prevent
water & air pump burn out. If the system is run dry the
pumps will shutdown prior to overheating.