background image

 

Rev. A 05/26 

AM11MF30-1 

 

 

2. Place the connector inside the electrical housing, and 

then place the housing lid.  Use screws and the lid 
from bag 5, to close the mist control / fan pole 
assembly (F-2, F-3).  Do not over tighten the screws. 

 

F-2 

 

 

F-3 

 
 

OPERATING INSTRUCTIONS  

 

Read this owner’s manual before operating this 
product.

 

1. To operate the misting fan, plug the power cord into 

a 120 VAC, 60Hz outlet.   

 

CAUTION:

 FAN AND/OR MISTING SYSTEM 

MAY START UP WHEN THE UNIT IS INITIALLY 
PLUGGED TO THE POWER OUTLET. 
 

2. Fan Operation (ON-OFF, Speed control) 
 

Pull Action 

Speed 

First 

High 

Second 

Medium 

Third 

Low 

Fourth 

“OFF” 

 
3. 

 

Fan Operation (Oscillation Control)  

To turn on the oscillation function, press down the 

oscillation switch, to stop the function simply pull-up 
the oscillation switch. The oscillation angle is 
approximately 50

°

 (G-1) 

 

 

 

G-1 

 
4. Misting Operation  

 
IMPORTANT:

 This product is designed to 

operate with DRINKING WATER ONLY.  Fan 
and/or misting system may start up when the unit 
is initially plugged to the power outlet.   
 

BEFORE STARTING

 

• Remove fill cap on power base assembly and fill with 

DRINKING WATER through the basket filter until tank 

is filled to approximately 1” below the bottom of the 
basket filter. 

• Add 

½

 teaspoon of unscented chlorine bleach to the 

water tank (approximately 5 drops per gallon of 
drinking water). 

• Replace cap and hand tighten.  
• The misting function of this product is turned on by 

simply rotating the switch on the fan pole assembly, 
clockwise to PRIME (G-2).  Once water begins to flow 
from the nozzles rotate the switch back to MIST. It 
may take up to 2 minutes for a new misting fan to start 
misting, and it is normal for air to come before water. 

• Once the system has been primed it does not need to 

be primed again unless the system has been 
completely drained. 

 

 

G-2 

• Automatic Shutoff 
  The Misting Fan has a built in safety feature to prevent 

water & air pump burn out. If the system is run dry the 
pumps will shutdown prior to overheating.  

Содержание AM11MF30-1

Страница 1: ...y maintenance on the Misting Fan 6 This Misting Fan shall not be used in potentially dangerous conditions such as flammable explosive or chemically loaded environments 7 The Misting Fan shall be completely assembled according to these instructions before connecting to a power source WARNING DO NOT USE A THREE PRONG TO TWO PRONG ADAPTER IMPROPER CONNECTION MAY CREATE A RISK FOR ELECTRICAL SHOCK 8 T...

Страница 2: ... mm Pressure Washer C 1 4 8 mm Flat Washer D 2 1 Electrical Enclosure Top E 2 2 ST 3 5 x 14 Screw F 2 1 Electrical Enclosure Bottom G 3 2 ST 4 0 x 12 Screw H 4 2 ST 3 0 X 14 I 5 1 Electrical Box Lid J 5 1 Electrical Enclosure K 5 2 ST 3 5 x 10 Screw All parts of this appliance are packed in one carton A B C D F E G H I J K ...

Страница 3: ...0 Manual FAN POLE ASSEMBLY TO POWER BASE ASSEMBLY 1 Align fan pole assembly OFF MIST PRIME switch to the Ventilation Grill Gently pull hoses from power base assembly A 1 A 1 2 Fasten four places the fan pole assembly to the power base assembly by using fasteners from bag 1 A 2 A 2 3 Fasten electrical housing with 2 screws from bag 2 B 1 B 1 1 2 4 3 5 6 8 OFF MIST PRIME switch SWITCH Ventilation gr...

Страница 4: ...g full you should feel two clicks C 3 Failure to do so could result in a leaky connection To remove the hose slide the hose out of the fitting while pushing the plastic ring on the fitting in C 4 FAN POLE ASSEMBLY TO MOTOR ASSEMBLY 1 Attach motor to the Center Pole and fasten securely D 1 Remove the two screws pre installed on the top of the Fan Pole align the Fan Motor on the pole with the mounti...

Страница 5: ...s of the fan guard E 3 E 4 E 2 E 3 3 Place the small screw and nut at the bottom hole to secure the forward and rear guards E 4 E 4 4 Connect nozzle housing by gently pushing the attachment legs on the front guard wire E 5 E 5 AIR WATER AND ELECTRICAL CONNECTIONS 1 Connect the air and water tubes to the connectors on the Mist Control Fan Pole Assembly The water is the smaller tube Make sure the tu...

Страница 6: ... to operate with DRINKING WATER ONLY Fan and or misting system may start up when the unit is initially plugged to the power outlet BEFORE STARTING Remove fill cap on power base assembly and fill with DRINKING WATER through the basket filter until tank is filled to approximately 1 below the bottom of the basket filter Add teaspoon of unscented chlorine bleach to the water tank approximately 5 drops...

Страница 7: ... turning clockwise CLEANING BASKET FILTER Remove fill cap and remove basket filter Rinse debris from filter with running water Replace basket filter and fill cap CONDITIONING WATER TANK Conditioning the water tank ensures that the cooling system will operate at optimal levels throughout the life of the system It is suggested that the tank be conditioned at an interval of every 4th filling or once ...

Страница 8: ...le 1 Replace air filter 2 Turn off fan motor and feel any air leaks on hoses 3 Order and replace nozzle holder Water dripping from drain plug 1 Drain plug not seated 2 Drain plug seal is missing or damage 1 Properly seat drain plug 2 Replace drain plug seal SAFETY WARRANTY WARRANTY ONE YEAR FULL WARRANTY This product is warranted for one year from the date of purchase against defects in materials ...

Отзывы: