INSTALLATION INSTRUCTIONS
Heater installation must be carried out by qualified personnel in compliance with local National Codes
(NEC) as well as any other applicable standards. Failure to comply with applicable requirements could
result in personal injury and/or property damage. Wiring procedures and connections shall be made in
accordance with national and local electrical codes having jurisdiction.
AURA infrared heaters produce radiant heat that warms people and objects, rather than the air around them.
The heater can be wall or ceiling mounted and includes brackets which allow the user to direct the infrared heat
where desired.
To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of
the heater.
2.1
INSTALLATION CLEARANCE DISTANCES
DANGER FIRE HAZARD
The minimum clearances indicated on the nameplate and in the user manual must be observed at the time of
installation. Allow at least 6
’
(1.5 m) between all sides of the heater to flammable objects.
CAUTION: High temperatures are present, risk of fire! Keep electrical cords, drapery, furnishings and other
combustibles at least 6 feet (1.8m) from the front of the heater and away from the sides and rear.
Minimum Clearance Distances
Floor
Ceiling
Adjacent walls
8’ (2.4 m)
1’ (30 cm)
5’ (1.5m)
Wall Mounted Clearances
Ceiling Suspended Clearances
2.2
ELECTRICAL INSTALLATION
Safety Precautions
1.
Each power supply circuit must be properly grounded.
2.
Use a certified ground fault protection device for wet environment installations.
3.
Use a proper electrical connection box
4.
Supply voltage and frequency must correspond to the electrical rating
indicated on unit’s
information
plate