Aumuller USKM Скачать руководство пользователя страница 3

Assembly Instruction
USKM

 C

OMMISSIONING

 / R

UN

-

ON

 

TIME

3

Multiple or sequential control module

With the function 

multiple control module

 two or three

drives are operated simultaneously. 
In the 

sequence control mode

, the drives are connected

in series -  depending on the selected sequence control. Here 
the shutdown of a drive is the start signal of the next drive.

Post cycle locking

As  soon  as  the 

USKM

  has  switched  off  the  drives  and

locking drives in one running direction, it does not permit 
any further operation - in this direction. 
Only after reversing the polarity of the input voltage - in the 
opposite direction - the 

USKM

 is reactivated.

Cut-off current surveillance 

The  current  consumption  of  the  connected  drives  and
locking  drives  is  permanently  monitored.  When  the  set 
value  has  been  exceeded,  the 

USKM

  switches  off  the 

connected motor. If a drive stops, for example, because of a 
defected cable, the 

USKM

 recognizes this as undercurrent. 

All connected drives and locking drives are switched OFF. 

Switch-off  function  for  drives  with  internal 
load dependent cut-off switch (e.g. OFV1)

These  drives  switch  off  by  its  own,  if  the  current  con-
sumption drops below a certain trashold. This state is not
displayed on the 

USKM

 as an error message.

If  the  current  consumption  of  the  drive  exceeds  the  set
trashold  (max.  2,4  A),  this  is  signaled  as  a  fault  (the

LED 

status display indicates red fast blinks) and all motors

are switched off.

ON

OMRON

XXXXX

OMRON

XXXXX

OMRON

XXXXX

1 2 3 4 5 6 7 8 9 10

M2

M1

V10

V14

V11 V12

V13

1

5

1

5

2

4

2

4

3   

1

5

2

4

3   

3

Changing  the  factory  set  run-on  time  of  2
seconds can lead to drive and window case-
ment demage. 
For  damage  -  caused  by  the  change  of  the
run-on time - 

A

UMÜLLER

 assumes no liability.

Larger  screwdriver  can  lead  to  mechanical
damage.

!

!

2

3

1

Run-on time (time values and voltage values)

Seconds

1,0

1,5

2,0

2,5

3,0

3,5

4,0

4,5

5,0

Volt

1,0

1,5

2,0

2,5

3,0

3,5

4,0

4,5

5,0

The  run-on  time  is  the  internal  switch-off-time  set  at  the 

USKM

 for the monitoring of the parallel operation of 2 or

3  drives.  It  determines  the  misaligment  between  the
drive-strokes,  which  results  from  the  multiplication  of  the 
run-on time and the speed of the drives.
The  run-on  time  between  the  switch-off  point  of  the  fi rst 
drive  -  by  overload  or  low  voltage  -  and  the  forced  shut-
down of the other drives in parallel operation, can be set on 
the circuit board with a potentiometer 

Œ

 in the range of

0 to 5 seconds. The factory setting is 2 seconds. 

 

¢

Operate  the  potentiometer 

Œ

  with  a  screwdriver

 

(size 

0

). 

The  set  run-on  time  can  be  measured  with  a  stopwatch.
An error must be simulated to a drive output  and the time  
must  be  measured  in  which  the  other  drives  operated  in 
parallel running mode are switched off.
Alternatively, the DC voltage at the two measuring points 

MP1 (-)

 

 and 

MP2 (+)

 

Ž

 has to be measured - with a 

digital  multimeter  -  and  converted  into  time  according  to 
the formula 

t = V

.

S

ETTING

 

THE

 

RUN

-

ON

 

TIME

 

IN

 

PARALLEL

 

RUN

 

WITH

 

MULTI

-

DRIVE

 

OPERATION