5
Assembly Instruction
FTA 600
Risk analysis in accordance with DIN EN 60335-2-103
Contact-free anti-trap protection
(20.ZAA.8.1)
Passive infra-red and active light sensors
or
pressure mats
Contact-based anti-trap protection
(20.ZAA.8.2)
Pressure-sensitive safety switch strips
or
Motor current monitoring systems
(internal and external)
Hold-to-run switch:
stops movement at HSK < 20 mm
at a closing force of > 150 N at HSK
(20.ZAA.5)
Operating element in
direct range of vision:
a.) Key switch or
b.) other switch,
then: installation > 1,5 m,
inaccessible for public
(7.12.1)
R
ISK
EVALUATION
Keep people away during closing!
Declaration of Conformity
for window + CE label
!
C
AUTION
Protection devices
!
C
AUTION
Using drives
NSHEV in accordance
with EN12101-2
without dual purpose for ventilation
NSHEV in accordance
with EN12101-2
with dual purpose for ventilation
(1.Z.109)
Natural ventilation
Installation height of drive:
> 2,5 m above fl oor
(ZAA.20.1)
Opening at HSK: < 200 mm and
Speed at HSK:
CLOSE
<15 mm/s /
OPEN
< 50 mm/s
(20.ZAA.2)
Yes
Yes
No
No
Risk covered by
Declaration of Conformity
for window drives
Observe danger at NSK
< 2,5 m above fl oor!
!
C
AUTION
Risk analysis is not required!
Keep people away during closing!
By opening width of > 200 mm,
close via hold-to-run switch!
!
C
AUTION
The casement measurements supplied
are only for orientation purposes.
It is imperative that the
force-path
diagram
of the drives are observed.
N
OTE
P
RELIMINARY
REMARK
01
Casement data
Facade:
bottom-hung
window,
top-hung
win-
dow,
side-hung
window.
Dach:
roof window / sky light.
Opening direction: inward / outward opening.
Profi le material:
aluminum, steel, plastic or wood.
When inspecting the drives for conformity with on-site
requirements the following items must be observed:
• total weight of casement (glass + frame),
• additional loads: snow load / wind load
(suction / pressure),
• casement size (FAB x FAH),
• side ratio FAB / FAH,
• installation / inclination angle,
• required opening area (geometric / aerodynamic),
• crosswind
infl uences,
• driving force and stroke,
• mounting site at the window frame and casement
frame.