INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
26
When the
"hp + elect"
or
"electric"
options are off ered, two
warning screens will appear:
then
elec. cable
size Ok?
no
size OK?
no
size OK?
yes
These screens serve to alert you to the fact that you are about to
activate the electrical back-up
The option you select will only be activated after you have
confi rmed it.
Is the HRC
70
Pilot cable wide enough?
Check in the § "Connecting the Pilot to
the power supply" section to ensure that the
diametre of the power supply cable is large
enough to support the strength of the electrical
current used by the appliance.
CONFIGURA.
Press the dial to access the
H
RC
70
Heat Pump
options
The "
Configuration"
sub-menu allows you to choose the
Heat Pump model as well as the type of circuit and type of
controls fi tted. The settings specifi c to each confi guration are
automatically adjusted by the software.
See the hydraulics diagrams in the appendices.
4.2.2 -
Configuration
of the HRC
70
Heat Pump
and circuits
Enter
not used
C
-
1
RADIAToRs
C
-
1
floor heat.
C
-
1
4.2.2.2 - Confi guring circuit 1
To deactivate circuit 1(no
circuit or
permanent pool
( winter)
For a radiator circuit installed
as circuit 1
For an underfl oor heating
circuit (low temperature)
installed as circuit 1
Enter
Enter
Enter
no CTRL
A
-
1
thermosta.
a
-
1
INT. sens.
A
-
1
Connect one of the following ONLY:
- TEMPERATURE SENSOR with DISPLAY (Ref. 751009)
- ROOM THERMOSTAT (Ref. 710172)
Any other thermostat could cause a malfunction
and thus render the warranty null and void.
4.2.2.3 - Circuit 1 temperature control
When there is no temperature
control for circuit 1 (heating
curve only)
When a thermostat (dry
contact) is controlling circuit 1
temperature
When a temperature sensor
with display is controlling
circuit 1 temperature
Enter
Enter
Enter
NB:
If circuit 1 is an underfl oor heating circuit, it is
mandatory to fi t a temperature control.
4.2.2.1 - Heat Pump model
Select the Heat Pump Model which you have installed.
The diff erent heat Pump Models will appear in the following
order:
HRC
70
- 17 / HRC
70
- 25 / HRC
70
- 20 / HRC
70
- 35
HRC
70
- 7 / HRC
70
- 11
hrc70
-
17
Hp
hrc70
-
7
HP
Enter
Enter
To confi rm the choice of Heat
Pump model as the HRC
70
17kW
To confi rm the power level of
the HRC
70
Heat Pump model
(7kW in the picture shown
here)
To select of Heat Pump model as the HRC
70
25 - 20 - 35 - 7 or 11kW
Exemple