INSTALLER
7 & 11kW HRC
70
HIGH TEMPERATURE HEAT PUMP
-
24
4.1.1 - Display screen: description of symbols
and their meaning
9-character
message
Display zone for time
and temperature
Day
4.1 - Control panel
Menu
On / Off
Clock
settings
Dial
Display screen
Symbol
Meaning
Summer mode in progress
Heat pump running
(compressor and fan running)
De-icing in progress
Electrical back-up is running
Boiler back-up request
Heat Pump circulator pump running
Heating circuit 1 circulator pump running
Heating circuit 2 circulator pump running
Domestic hot water production in progress
Setting / setting display
Time or programme is being set
"Comfort" mode
"Economy" mode
"Frost protection" mode
"Holiday" mode
4 - COMMISSIONING
• All work carried out on the water circuits and electrical
installations must be carried out by a qualifi ed professional and
in accordance with current rules and regulations.
• Fill the installation with water and treat the water.
• Purge the heating circuits (open the air valves situated on the
highest points of the installation until all trapped air has been
released).
• Check that all circuits are properly sealed.
• Check that the power supply voltage is correct at the mains
switch.
• Check that all hydraulic connections have been properly
tightened and that there are no leaks.
• Check that all the valves are open, that there is water in the
heating circuit and that nothing is stopping the water from
circulating freely in the heat exchanger and the hydraulic circuit.
• Check that the sludge valve is correctly fi tted and that nothing is
blocking its screen fi lter.
• Once all of these checks have been carried out, switch the
appliances on.
• Configure the installation.
The appliance is pre-confi gured for the following system:
- 17 kW Heat Pump
- Heat Pump without back-up
(neither boiler or electrical)
- 1 radiator circuit
- 1room thermostat to control radiator circuit
temperature
If necessary, this confi guration can be modifi ed using the
"Installer" menu.
N.B:
Frost protection for the Heat Pump
When the Heat Pump is switched off (temporarily or defi nitively),
and the temperature of the outgoing water from the Heat Pump
falls belo
w 5°C, the circulator pump starts up and will only stop
running when the water temperature reaches 11°C.
The installation must NEVER be switched
on WITHOUT WATER in the heating circuit